Zobrazeno 1 - 10
of 24
pro vyhledávání: '"Paul A. Picot"'
Publikováno v:
Medical Imaging 2021: Physics of Medical Imaging.
The MTF and DQE of an x-ray detector are important metrics of performance. They are generally measured following IEC guidelines which requires the use of raw (unprocessed) images. However, many detectors now incorporate processing algorithms that are
Publikováno v:
Magnetic Resonance in Medicine. 78:1599-1606
Purpose To develop a new method capable of directly measuring specific absorption rate (SAR) deposited in tissue using the thermoacoustic signal induced by short radiofrequency (RF) pulse excitation. Theory A detailed model based on the thermoacousti
Autor:
R. L. Bondar, Flo Stein, Jorge M. Serrador, Todd T. Schlegel, A. H. Rupert, Paul A. Picot, Mahmood S. Kassam, Scott J. Wood
Publikováno v:
Journal of Applied Physiology. 91:1986-1994
We examined the effects of 30 min of exposure to either +3GX(front-to-back) or +GZ (head-to-foot) centrifugation on cerebrovascular responses to 80° head-up tilt (HUT) in 14 healthy individuals. Both before and after +3 GX or +3 GZ centrifugation, e
Publikováno v:
Magnetic Resonance in Medicine. 46:1093-1098
A hybrid two-dimensional relaxometry (2DR) sequence was used to simultaneously measure both the spin-spin (R2) and spin-lattice relaxation rates (R1) of skeletal muscle in vivo. The 2DR sequence involved a 180° inversion pulse followed by a variable
Publikováno v:
Kinesiology Publications
ResearcherID
ResearcherID
Background and Purpose —The relationship between middle cerebral artery (MCA) flow velocity (CFV) and cerebral blood flow (CBF) is uncertain because of unknown vessel diameter response to physiological stimuli. The purpose of this study was to dire
Publikováno v:
Ultrasound in Medicine & Biology. 21:1163-1176
Doppler ultrasound flow measurement techniques are often validated using phantoms that simulate the vasculature, surrounding tissue and blood. Many researchers use rubber tubing to mimic blood vessels because of the realistic acoustic impedance, robu
Publikováno v:
Ultrasound in Medicine & Biology. 21:1199-1209
A system is described in which the volume flow rate of blood in a vessel is determined using transverse colour Doppler ultrasound imaging. The system measures rapidly the two-dimensional velocity profile of blood flowing through a vessel. By integrat
Publikováno v:
Ultrasound in Medicine & Biology. 21:807-816
A quantitative in vitro flow study was performed by using a three-dimensional colour Doppler imaging system. This system was based on a clinical ultrasound instrument with its transducer mounted on a motor-driven translation stage. A vascular and tis
Autor:
P.M. Embree, Paul A. Picot
Publikováno v:
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. 41:340-345
The direct measurement of the velocity profile of blood flowing in a vessel yields a volume flow estimate that is more accurate than single-point Doppler ultrasound. A volume flow estimate is made by assuming a circularly symmetric velocity field and
Autor:
Ken C. Chu, Linda M. Gowman, David W. Holdsworth, Richard Frayne, Maria Drangova, Brian K. Rutt, Daniel W. Rickey, Aaron Fenster, Curtis B. Caldwell, Paul A. Picot
Publikováno v:
Medical Physics. 20:415-425
A technique for producing accurate models of vascular segments for use in experiments that assess vessel geometry and flow has been developed and evaluated. The models are compatible with x-ray, ultrasound, and magnetic resonance (MR) imaging systems