Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Patrick Wraith"'
Autor:
Jacqueline M. Barnett, Bertrand M. Monnier, Sue Tyler, David West, Hugh Ballantine-Dykes, Ed Regan, Patrick Wraith, Janice Kiely, Richard Luxton
Publikováno v:
Sensing and Bio-Sensing Research, Vol 27, Iss , Pp - (2020)
The resonant coil magnetometer quantifies paramagnetic particles (PMPs) and has been used to develop magneto-immunoassays in a range of formats. The advantage of magneto-immunoassays is that they are relatively inexpensive, portable, easy to perform
Externí odkaz:
https://doaj.org/article/8708fc80ff454bc8b7dc4398a9280b86
Autor:
Jacqueline M. Barnett, Patrick Wraith, Janice Kiely, Raj Persad, Katrina Hurley, Peter Hawkins, Richard Luxton
Publikováno v:
Biosensors, Vol 4, Iss 3, Pp 204-220 (2014)
We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM) to quantify paramagnetic particles (PMPs) in immunochromatographic (lateral flow) assays. Lateral flow assays were developed using PMPs for the measurement of
Externí odkaz:
https://doaj.org/article/377949c190ef486696ff319b7b7cf044
Publikováno v:
BioCAS
A novel passive bio-sensing method, which electrically connects a conventional biosensor to a surface acoustic wave (SAW) device, is proposed for passively sensing bio-impedance for zero-power wearable applications. The biosensor attached to the SAW
Autor:
Sue Tyler, David Mckay West, Richard Luxton, Janice Kiely, Patrick Wraith, Bertrand M. Monnier, Hugh Ballantine-Dykes, Ed Regan, Jacqueline M. Barnett
Publikováno v:
Sensing and Bio-Sensing Research, Vol 27, Iss, Pp-(2020)
The resonant coil magnetometer quantifies paramagnetic particles (PMPs) and has been used to develop magneto-immunoassays in a range of formats. The advantage of magneto-immunoassays is that they are relatively inexpensive, portable, easy to perform
Autor:
Raj Persad, Patrick Wraith, Richard Luxton, Janice Kiely, Katrina Hurley, Peter Hawkins, Jacqueline M. Barnett
Publikováno v:
Biosensors, Vol 4, Iss 3, Pp 204-220 (2014)
Biosensors; Volume 4; Issue 3; Pages: 204-220
Biosensors
Biosensors; Volume 4; Issue 3; Pages: 204-220
Biosensors
We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM) to quantify paramagnetic particles (PMPs) in immunochromatographic (lateral flow) assays. Lateral flow assays were developed using PMPs for the measurement of
Publikováno v:
Sensors and Actuators B: Chemical. 139:538-542
This paper describes work that formed a part of an investigation to increase the detection sensitivity of a magneto-immunoassay. The study involved the characterisation of paramagnetic particles (PMPs) from a range of manufacturers in order to determ
Publikováno v:
IET Science, Measurement & Technology. 1:270-275
A biosensor and detection system that can provide measurement of analyte concentration within a test sample in four minutes is presented. The biosensor uses an immunoassay with micrometre-sized paramagnetic particle (PMP) labels for quantification. A
Lock-in Amplifier as a Sensitive Instrument for Biomedical Measurement : Analysis and Implementation
Publikováno v:
TELKOMNIKA Indonesian Journal of Electrical Engineering. 12
—A novel, integrated lysis and immunoassay method- ology and system for intracellular protein measurement are de- scribed. The method uses paramagnetic particles both as a lysis agent and assay label resulting in a rapid test requiring minimal oper
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::37636dcc6d8ae1e1d98519cc09411344
https://hdl.handle.net/10576/4801
https://hdl.handle.net/10576/4801
Publikováno v:
IET Science, Measurement & Technology. 6:456
Impedance-based cytotoxicity testing provides a simple, real-time and non-invasive assay technique that interferes minimally with cell morphology and function. In this study, impedimetric measurements of ECV304 cells with increasing concentrations of