Zobrazeno 1 - 10
of 48
pro vyhledávání: '"Patrick Reichart"'
Autor:
I. Portnykh, Akihiko Kimura, N. P. Barradas, Sören Möller, Tiago Fiorini da Silva, A. Lagoyannis, M. Li, D. Ridikas, Stephen E. Donnelly, Kalle Heinola, Hicham Khodja, Daniel Primetzhofer, Patrick Reichart, Sabina Markelj, Anna Widdowson, Per Petersson, Y.Q. Wang, Tommy Ahlgren, O. Kakuee, S. M. Gonzalez de Vicente, M. Mayer, G. Apostolopoulos, M. Mudrinic, S. Charisopoulos, Marek Rubel, Eduardo Alves, Stjepko Fazinić
Publikováno v:
Nuclear Fusion
Nuclear Fusion, 2019, 60, pp.025001. ⟨10.1088/1741-4326/ab5817⟩
Nuclear Fusion, IOP Publishing, 2019, 60, pp.025001. ⟨10.1088/1741-4326/ab5817⟩
Nuclear Fusion, 2019, 60, pp.025001. ⟨10.1088/1741-4326/ab5817⟩
Nuclear Fusion, IOP Publishing, 2019, 60, pp.025001. ⟨10.1088/1741-4326/ab5817⟩
International audience; Following the IAEA Technical Meeting on “Advanced Methodologies for the Analysis of Materials in Energy Applications Using Ion Beam Accelerators”, this paper reviews the current status of ion beam analysis techniques and s
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::554df96df69f58fc7e5a7c4a52b5b1dd
https://vinar.vin.bg.ac.rs/handle/123456789/10140
https://vinar.vin.bg.ac.rs/handle/123456789/10140
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 371:178-184
Using 17 MeV deuterons as a micrometer focused primary beam, we performed deuterium microscopy by using the deuteron–deuteron (dd) scattering reaction. We describe our new box like detector setup consisting of four double sided silicon strip detect
Traditional methods to measure water in nominally anhydrous minerals (NAMs) are, for example, Fourier transformed infrared (FTIR) spectroscopy or secondary ion mass spectrometry (SIMS). Both well-established methods provide a low detection limit as w
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6f91196883785f157372fd9484ba82ad
http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-359887
http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-359887
Autor:
Stephan Eschbaumer, Patrick Reichart, Günther Dollinger, T. Rösch, T. Vallentin, T. Haase, Christoph Greubel, M. Moser
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 348:43-47
A new microbeam slit system for high beam currents of 10 μA was built up to improve the brightness transport of a proton beam with a kinetic energy of up to 25 MeV into the microprobe SNAKE. The new slit system features a position accuracy of less t
Autor:
T. Vallentin, M. Moser, B. Urban, Patrick Reichart, Christoph Greubel, Günther Dollinger, W. Carli, K. Peeper
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 348:34-42
Basic requirement for ion microprobes with sub-μm beam focus is a high brightness beam to fill the small phase space usually accepted by the ion microprobe with enough ion current for the desired application. We performed beam transport simulations
Autor:
Stefan Wagner, M. Moser, K. Peeper, Astrid Pundt, Christoph Greubel, Patrick Reichart, Günther Dollinger
Publikováno v:
International Journal of Hydrogen Energy. 38:13822-13830
Hydrogen absorption in thin metal films clamped to rigid substrates results in mechanical stress that changes the hydrogen's chemical potential by ΔμH(σ) = −1.124σ kJ/molH for σ measured in [GPa]. In this paper we show that local stress relaxa
Autor:
Patrick Reichart, Günther Dollinger, E. Markina, K. Peeper, M. Balden, Stefan Lindig, M. Mayer, M. Moser
Publikováno v:
Journal of Nuclear Materials. 438:S887-S890
The mapping of hydrogen distributions in 3 dimensions and its correlation with structural features allow further insight into mechanisms of hydrogen trapping in tungsten. We studied hydrogen distributions in 25 μm thick polycrystalline tungsten foil
Autor:
P. Hartung, Christoph Greubel, K. Peeper, W. Carli, Patrick Reichart, Günther Dollinger, M. Moser
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 273:226-230
In order to improve the lateral resolution of the 3D hydrogen microscopy by proton–proton scattering at the Munich microprobe SNAKE, we have installed a new multicusp ion source for negative hydrogen ions manufactured by HVEE at the Munich 14 MV ta
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 273:254-257
Protons at energies between 10 and 25 MeV are a very sensitive probe for hydrogen using coincident proton–proton scattering with the possibility for depth profiling samples up to several 100 μm thickness. At the Munich microprobe SNAKE we have dev
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 269:2217-2228
We present a phase shift analysis of differential elastic proton–proton scattering cross sections ( d σ / d Ω ) pp in the energy range from 1.9 MeV to 50 MeV and laboratory scattering angles θ lab = 15 – 75 ° . That results in an accurate rep