Zobrazeno 1 - 10
of 34
pro vyhledávání: '"Pathaleswar"'
Publikováno v:
In Nuclear Inst. and Methods in Physics Research, A 1 February 2017 844:53-61
Autor:
Mamta Jangra, M. N. Saraf, V. M. Datar, G. Majumder, null Pathaleswar, B. Satyanarayana, S. S. Upadhya
Publikováno v:
Springer Proceedings in Physics ISBN: 9789811923531
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::4d9dde5520d47386238f3ee3412116af
https://doi.org/10.1007/978-981-19-2354-8_146
https://doi.org/10.1007/978-981-19-2354-8_146
Autor:
M. N. Saraf, E. Yuvaraj, V. M. Datar, G. Majumder, null Pathaleswar, null Pethuraj, B. Satyanarayana, R. R. Shinde, D. Sil, S. Thoithoi, S. S. Upadhya
Publikováno v:
Journal of Physics: Conference Series. 2374:012102
The India-based Neutrino Observatory (INO) has proposed to build a magnetised Iron-CALorimeter (ICAL) to study atmospheric neutrinos. The ICAL detector will use 28,800 Resistive Plate Chambers (RPCs) of 2 m × 2 m area as active detector elements. Th
Autor:
Pathaleswar, R. R. Shinde, S. Rajkumarbharathi, M. N. Saraf, L. Umesh, B. Satyanarayana, E. Yuvaraj, Honey
Publikováno v:
Springer Proceedings in Physics ISBN: 9789813344075
Cosmic Muon Tracker (CMT) is a portable charged particle (Muons) tracker, which can be used to track and acquire live Muon events. This compact detector module is expected to serve as an excellent outreach tool for a wide range of students—schools
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::e23e72ce21fb651fb4161ba3603c28f6
https://doi.org/10.1007/978-981-33-4408-2_96
https://doi.org/10.1007/978-981-33-4408-2_96
Autor:
K. C. Ravindran, V. M. Datar, Gobinda Majumder, R. R. Shinde, D. Sil, S. S. Upadhya, M. N. Saraf, E. Yuvaraj, N. K. Mondal, P. Verma, Suryanarayan Mondal, S. Pethuraj, P. Nagaraj, B. Satyanarayana, Pathaleswar
Publikováno v:
Springer Proceedings in Physics ISBN: 9789813344075
The INO-ICAL experiment is a proposed underground particle physics experiment to study the neutrino oscillation parameters. Twelve layers of 2 m \(\times \) 2 m RPC stack was built to study the performance of RPC detectors which are made in the India
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c76c8cf232ecb8acfe3549d12d395a2c
https://doi.org/10.1007/978-981-33-4408-2_112
https://doi.org/10.1007/978-981-33-4408-2_112
Autor:
N. Ayyagiri, B. Satyanarayana, R. R. Shinde, M. N. Saraf, Umesh Shas, S. S. Upadhya, P. Nagaraj, S. Moitra, Pathaleswar, Rajkumar Bharathi, E. Yuvaraj, A. Padmini, Megha Thomas, A. Behere, U. Gokhale, V.B. Chandratre, A. Lokapure, K. C. Ravindran, D. Sil, P. K. Kaur, Menka Sukhwani, G. Majunder, Shantanu Joshi, H. Kolla, A. Manna, V. M. Datar, S. Sikder, M. Punna
Publikováno v:
Springer Proceedings in Physics ISBN: 9789813344075
Magnetized iron calorimeter (ICAL) detector built using Resistive Plate Chambers (RPCs), which are interleaved between the iron plates, is proposed by India-based Neutrino Observatory (INO), to study atmospheric neutrinos [1]. Ten layers of RPCs are
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::0cee2acaa22e3d0bfdb28bfdc00b3792
https://doi.org/10.1007/978-981-33-4408-2_108
https://doi.org/10.1007/978-981-33-4408-2_108
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 844:53-61
The intrinsic gain of a single gap Resistive Plate Chamber (RPC) is affected by several factors, e.g., variation in the thicknesses of glass electrode, button and side spacer, different composition of gas due to improper flow, leaks in the detector v
Publikováno v:
XXII DAE High Energy Physics Symposium ISBN: 9783319731704
We have developed an 8-channel preamplifier-discriminator board using the NINO ASIC. The efficiency of the RPC detectors using the NINO preamplifier board is found to be about 92% and the power consumption is about 70 mW per channel. Design, producti
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::afd19e4337311fcfaf78c64c49bd4d6b
https://doi.org/10.1007/978-3-319-73171-1_134
https://doi.org/10.1007/978-3-319-73171-1_134
Autor:
A. Behere, U. Gokhale, S. Karmakar, Pathaleswar, S. Roy, V. M. Datar, R. R. Shinde, Prakash Kumar, P. Verma, T. Kasbekar, Chitra, S. M. Raut, Nitin Chandrachoodan, S. Dasgupta, N. Panyam, M. Punna, S. Mohanan, N. Ayyagiri, S. S. Upadhya, G. Majumder, A. Manna, M. Maity, S. Prafulla, N. K. Mondal, S. D. Kalmani, N. Kamble, D. Das, S. Moitra, S. Sikder, S. Achrekar, Anil Prabhakar, A. Jain, K. C. Ravindran, M. N. Saraf, H. Kolla, V. B. Chandratre, D. Sil, P. K. Kaur, T. K. Kundu, S. Aniruddhan, A. Lokapure, E. Yuvaraj, Megha Thomas, M. Sukhwani, P. M. Nair, S. Padmini, B. Satyanarayana, N. Krishnapura, M. Rahaman, Shantanu Joshi, P. Abinaya
Publikováno v:
Springer Proceedings in Physics ISBN: 9789811313127
India-based Neutrino Observatory (INO) [1] has proposed construction of a 50k ton magnetised Iron Calorimeter (ICAL) in an underground laboratory located in South India. Main aims of this, now funded project are to precisely study the atmospheric neu
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::eda08391d311d1a8b13139d359123655
https://doi.org/10.1007/978-981-13-1313-4_55
https://doi.org/10.1007/978-981-13-1313-4_55
Publikováno v:
XXII DAE High Energy Physics Symposium ISBN: 9783319731704
There are many sources affecting the time resolution of a large area single gap RPC, the dominant one being the position dependent gain. There are several reasons for this gain variation, e.g. variation in the gas composition due to improper flow and
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::cbf7baef1f1ba2601569d2df40a89381
https://doi.org/10.1007/978-3-319-73171-1_20
https://doi.org/10.1007/978-3-319-73171-1_20