Autor:
Ann C. Gaffey, Scott M. Damrauer
Publikováno v:
Semin Intervent Radiol
Over the past 20 years, there has been tremendous progress in endovascular aneurysm repair techniques and devices. The application of new third- and fourth-generation devices (from 2003 onward) has led to changes in the incidence and management of en
Autor:
Thomas F. O'Donnell, John McCallum, Chun Li, Patric Liang, Rens R.B. Varkevisser, Marc L. Schermerhorn, Nicholas J. Swerdlow
Publikováno v:
Journal of Vascular Surgery, 70(2), 381-390. Mosby Inc.
Objective The Society for Vascular Surgery reporting standards for endovascular aneurysm repair (EVAR) consider the presence of a type I or type III endoleak a technical failure. However, the nature and implications of these endoleaks in fenestrated
Publikováno v:
Vascular Reconstructions ISBN: 9781071610879
This chapter discusses some techniques and tricks that are helpful for all vascular surgeons and interventionalists.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::14f22f0f8ba862bd11755a49f7bb6b14
https://doi.org/10.1007/978-1-0716-1089-3_36
https://doi.org/10.1007/978-1-0716-1089-3_36
Autor:
Sachinder Singh Hans
Publikováno v:
Challenging Arterial Reconstructions ISBN: 9783030441340
An 81-year-old male presented with a rupture of abdominal aortic aneurysm with prior endografting secondary to Type IA and Type III endoleak. Following repair of ruptured abdominal aortic aneurysm with endovascular repair (Palmaz stent, aortic cuff,
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5051699513e7bdb027dbe4e4e8035c8a
https://doi.org/10.1007/978-3-030-44135-7_72
https://doi.org/10.1007/978-3-030-44135-7_72
Autor:
Aubrey C. Galloway, Joshua M. Lader, Cezar Staniloae, Arzhang Fallahi, Deane E. Smith, Sohah N. Iqbal, Mathew R. Williams
Publikováno v:
The Annals of Thoracic Surgery. 105:e243-e245
A 78-year-old man with remote type-A dissection presented with acute-onset dyspnea. Twenty-two years prior, treatment for his aortic disease required replacement of ascending and arch aneurysms with a polyester graft (Dacron) using the graft inclusio
Autor:
S. Lowell Kahn
Publikováno v:
Oxford Medicine
The Palmaz XL stent (Cordis) is a stainless-steel stent designed to be manually mounted on a balloon. Cautious mounting is warranted to avoid potential mal-deployment of the stent. Several mounting techniques are utilized. This chapter delineates the
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::6afbc446df215182bc90dea8070b20cd
https://doi.org/10.1093/med/9780199986071.003.0006
https://doi.org/10.1093/med/9780199986071.003.0006
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Journal of Vascular and Interventional Radiology. 27:1716-1718
Autor:
Tetsuro Miyata, Kunihiro Shigematsu, Masaaki Kato, Takuya Hashimoto, Nobukazu Ohkubo, Katsuyuki Hoshina
Publikováno v:
Annals of Vascular Diseases. 7:34-39
Introduction: We retrospectively analyzed outcomes of patients who had undergone endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA) more than 3 years previously in a single institution. We compared outcomes between patients who u
Publikováno v:
Hong Kong medical journal = Xianggang yi xue za zhi. 22(6)
Introduction The use of a proximal Palmaz stent is a well-recognised technique to treat proximal endoleak in endovascular aortic repair. This study aimed to report the effectiveness and safety of an intra-operative Palmaz stent for immediate type 1a