Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Palenčár, Jakub"'
Publikováno v:
Measurement Science Review, Vol 22, Iss 6, Pp 293-307 (2022)
We address the problem of linear comparative calibration, a special case of linear calibration where both variables are measured with errors, and the analysis of the uncertainty of the measurement results obtained with the calibrated instrument. The
Externí odkaz:
https://doaj.org/article/5184e20aa46645e59d2733c347563f6b
Autor:
Molnar, Vieroslav, Fedorko, Gabriel, Honus, Stanislav, Andrejiova, Miriam, Grincova, Anna, Michalik, Peter, Palencar, Jakub
Publikováno v:
In Engineering Failure Analysis October 2020 116
Publikováno v:
Measurement Science Review, Vol 20, Iss 5, Pp 230-235 (2020)
The paper deals with a scientific approach for an increase of accuracy of measurement and possibilities for automation of the standard equipment for calibration and verification of float level gauges. They are applied in high-capacity fuel storage ta
Externí odkaz:
https://doaj.org/article/9edf70ceb5d542f3beb1192a607bf28b
Publikováno v:
Measurement Science Review, Vol 20, Iss 2, Pp 73-79 (2020)
The paper presents a matrix approach to the propagation of uncertainties in the realization of the ITS-90 using Standard Platinum Resistance Thermometers (SPRT) calibrated at Defining Fixed Points (DFPs). The procedure allows correlations to be inclu
Externí odkaz:
https://doaj.org/article/24e65ee1c7a44d92a0b28f50e21e8c3d
Autor:
Palenčár, Jakub1 jakub.palencar@stuba.sk, Dovica, Miroslav2 miroslav.dovica@tuke.sk, Palenčár, Rudolf3 rudolf.palencar@stuba.sk, Halaj, Martin1 martin.halaj@stuba.sk, Kováčiková, Anna4 anna.kovacikova@stuba.sk, Šooš, Ľubomír3 lubomir.soos@stuba.sk
Publikováno v:
Quality Innovation Prosperity / Kvalita Inovácia Prosperita. 2022, Vol. 26 Issue 2, p88-100. 13p.
Autor:
Palenčár Rudolf, Sopkuliak Peter, Palenčár Jakub, Ďuriš Stanislav, Suroviak Emil, Halaj Martin
Publikováno v:
Measurement Science Review, Vol 17, Iss 3, Pp 108-116 (2017)
Evaluation of uncertainties of the temperature measurement by standard platinum resistance thermometer calibrated at the defining fixed points according to ITS-90 is a problem that can be solved in different ways. The paper presents a procedure based
Externí odkaz:
https://doaj.org/article/dbabaea2677f43febf0b3479fcef9684
Publikováno v:
Annals of the Faculty of Engineering Hunedoara - International Journal of Engineering. Feb2017, Vol. 15 Issue 1, p83-86. 4p.
Publikováno v:
Acta Technica Corviniensis - Bulletin of Engineering. Jan-Mar2017, Vol. 10 Issue 1, p97-100. 4p.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.