Zobrazeno 1 - 10
of 273
pro vyhledávání: '"P.F. van der Stelt"'
Autor:
P.F. van der Stelt
Publikováno v:
Dentomaxillofac Radiol
Over the past 50 years, computer technology has evolved enormously. This has made it possible to carry out radiography in a completely new way, allowing to process X-ray images in an advanced manner and to extract the information from the image data.
Autor:
P.F. van der Stelt
Publikováno v:
Nederlands Tijdschrift voor Tandheelkunde. 123:189-198
Cone beam computed tomography (CBCT) is a radiographic technique that has now been available in dentistry for about 20 years. The ability to display three-dimensional structures is of importance for many defects in the maxillofacial area. A disadvant
Autor:
P.F. van der Stelt
Publikováno v:
Nederlands Tijdschrift voor Tandheelkunde. 123:181-187
Panoramic radiographs are frequently used in dental practice in addition to bitewing radiographs and periapical radiographs. The way a panoramic photograph is created is different from that of a projection image, such as bitewing and periapical radio
Autor:
P.F. van der Stelt
Publikováno v:
Nederlands Tijdschrift voor Tandheelkunde, 122(5), 253-258. G J D Tholen N V
van der Stelt, P F 2015, ' Tandheelkundige radiologie: wet-en regelgeving ', Nederlands Tijdschrift voor Tandheelkunde, vol. 122, no. 5, pp. 253-258 . https://doi.org/10.5177/ntvt.2015.05.14252
van der Stelt, P F 2015, ' Tandheelkundige radiologie: wet-en regelgeving ', Nederlands Tijdschrift voor Tandheelkunde, vol. 122, no. 5, pp. 253-258 . https://doi.org/10.5177/ntvt.2015.05.14252
Since the discovery of X-rays, medical imaging has been one of its most important applications. In the course of years, understanding of the potentially harmful effects of radiation on tissue has substantially increased as a result of experience and
Publikováno v:
Dentomaxillofacial Radiology, 41(8), 645-648. British Institute of Radiology
Hassan, B A, Payam, J, Juyanda, B, van der Stelt, P & Wesselink, P R 2012, ' Influence of scan setting selections on root canal visibility with cone beam CT ', Dentomaxillofacial Radiology, vol. 41, no. 8, pp. 645-648 . https://doi.org/10.1259/dmfr/27670911
Hassan, B A, Payam, J, Juyanda, B, van der Stelt, P & Wesselink, P R 2012, ' Influence of scan setting selections on root canal visibility with cone beam CT ', Dentomaxillofacial Radiology, vol. 41, no. 8, pp. 645-648 . https://doi.org/10.1259/dmfr/27670911
Objectives The aim of this study was to assess the influence of scan setting selection, including field of view (FOV) ranging from small to large, number of projections and scan modes on the visibility of the root canal with cone beam CT (CBCT). Meth
Autor:
Luc Renambot, D.M. Germans, P.F. van der Stelt, S. van Daatselaar, Henri E. Bal, H.J.W. Spoelder
Publikováno v:
IEEE Transactions on Instrumentation and Measurement, 57(6), 1177-1184. Institute of Electrical and Electronics Engineers Inc.
Germans, D M, Spoelder, H J W, Renambot, L, Bal, H E, van Daatselaar, S & van der Stelt, P 2008, ' Measuring in virtual reality: a case study in dentistry ', IEEE Transactions on Instrumentation and Measurement, vol. 57, no. 6, pp. 1177-1184 . https://doi.org/10.1109/TIM.2008.915952
IEEE Transactions on Instrumentation and Measurement, 57(4), 1177-1184. Institute of Electrical and Electronics Engineers Inc.
Germans, D M, Spoelder, H J W, Renambot, L P M, Bal, H E, van Daatselaar, S & van der Stelt, P F 2008, ' Measuring in Virtual Reality: A Case Study in Dentistry ', IEEE Transactions on Instrumentation and Measurement, vol. 57, no. 4, pp. 1177-1184 . https://doi.org/10.1109/TIM.2008.915952
Germans, D M, Spoelder, H J W, Renambot, L, Bal, H E, van Daatselaar, S & van der Stelt, P 2008, ' Measuring in virtual reality: a case study in dentistry ', IEEE Transactions on Instrumentation and Measurement, vol. 57, no. 6, pp. 1177-1184 . https://doi.org/10.1109/TIM.2008.915952
IEEE Transactions on Instrumentation and Measurement, 57(4), 1177-1184. Institute of Electrical and Electronics Engineers Inc.
Germans, D M, Spoelder, H J W, Renambot, L P M, Bal, H E, van Daatselaar, S & van der Stelt, P F 2008, ' Measuring in Virtual Reality: A Case Study in Dentistry ', IEEE Transactions on Instrumentation and Measurement, vol. 57, no. 4, pp. 1177-1184 . https://doi.org/10.1109/TIM.2008.915952
For application specialists to accept virtual reality (VR) as a valid new measuring environment, we conducted several case studies. This paper describes a case study in dentistry in which VR is used to measure the length of the root canal of a tooth
Autor:
Christina Lindh, E Bleyen, Olivia Nackaerts, H Borghs, Hugh Devlin, P.F. van der Stelt, Reinhilde Jacobs, Sue Pavitt, Keith Horner, B Yan, K Karayianni, Elizabeth Marjanovic, Judith E. Adams
Publikováno v:
Dentomaxillofacial Radiology, 37, 282-287. British Institute of Radiology
Nackaerts, O, Jacobs, R, Devlin, H, Pavitt, S, Bleyen, E, Yan, B, Borghs, H, Lindh, C, Karayianni, K, van der Stelt, P, Marjanovic, E, Adams, J E & Horner, K 2008, ' Osteoporosis detection using intraoral densitometry ', Dentomaxillofacial Radiology, vol. 37, pp. 282-287 . https://doi.org/10.1259/dmfr/30424604
Nackaerts, O, Jacobs, R, Devlin, H, Pavitt, S, Bleyen, E, Yan, B, Borghs, H, Lindh, C, Karayianni, K, van der Stelt, P, Marjanovic, E, Adams, J E & Horner, K 2008, ' Osteoporosis detection using intraoral densitometry ', Dentomaxillofacial Radiology, vol. 37, pp. 282-287 . https://doi.org/10.1259/dmfr/30424604
Objectives: To determine the diagnostic accuracy of mandibular and maxillary bone densityin detecting osteoporosis using receiver operating characteristic (ROC) analysis.Methods: 671 women between 45 years and 70 years of age underwent dual energy X-
Publikováno v:
Li, G, Berkhout, W E R, Sanderink, G C H, Martins, M & van der Stelt, P F 2008, ' Detection of in vitro proximal caries in storage phosphor plate radiographs scanned with different resolutions ', Dentomaxillofacial Radiology, vol. 37, no. 6, pp. 325-329 . https://doi.org/10.1259/dmfr/62591340
Dentomaxillofacial Radiology, 37(6), 325-329. British Institute of Radiology
Dentomaxillofacial Radiology, 37(6), 325-329. British Institute of Radiology
Objectives: To investigate the effect of the scanning resolution of storage phosphor plate (SPP) radiographs on the detection of proximal caries lesions. Methods: 10 dentists evaluated 72 proximal surfaces of premolars with respect to caries from SPP
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c3389da089aee4167b606b41e80a09b1
https://dare.uva.nl/personal/pure/en/publications/detection-of-in-vitro-proximal-caries-in-storage-phosphor-plate-radiographs-scanned-with-different-resolutions(b5a04f98-638e-4d7c-af50-f7378e672bd2).html
https://dare.uva.nl/personal/pure/en/publications/detection-of-in-vitro-proximal-caries-in-storage-phosphor-plate-radiographs-scanned-with-different-resolutions(b5a04f98-638e-4d7c-af50-f7378e672bd2).html
Publikováno v:
Journal of Biomechanics, 41(10), 2206-2210. Elsevier
Geraets, W G M, van Ruijven, L J, Verheij, H G C, van der Stelt, P F & van Eijden, T M G J 2008, ' Spatial orientation in bone samples and Young's modulus ', Journal of Biomechanics, vol. 41, no. 10, pp. 2206-2210 . https://doi.org/10.1016/j.jbiomech.2008.04.016
Journal of Biomechanics, 41(10), 2206-2210. Elsevier Limited
Geraets, W G M, van Ruijven, L J, Verheij, H G C, van der Stelt, P F & van Eijden, T M G J 2008, ' Spatial orientation in bone samples and Young's modulus ', Journal of Biomechanics, vol. 41, no. 10, pp. 2206-2210 . https://doi.org/10.1016/j.jbiomech.2008.04.016
Journal of Biomechanics, 41(10), 2206-2210. Elsevier Limited
Bone mass is the most important determinant of the mechanical strength of bones, and spatial structure is the second. In general, thespatial structure and mechanical properties of bones such as the breaking strength are direction dependent. The mean
Autor:
J.M. Ostby, M. Noy, P. Gasiorek, F. Psomadellis, A. Asimidis, Silvia Pani, Sergios Theodoridis, T. Rokvic, E. Bletsas, R. Turchetta, Harris V. Georgiou, J. Leaver, Nikolaos Manthos, C. Venanzi, Gang Li, B. D. Price, Renata Longo, Geoff Hall, Jennifer Griffiths, C Esbrand, P.F. van der Stelt, Frixos A Triantis, Helene Schulerud, M Metaxas, J. Jones, D. Machin, Gary Royle, D. Cavouras, Robert D. Speller, A. Fant, J. Matheson
Publikováno v:
Physica Medica-European Journal of Medical Physics, 24(2), 117-121. Associazione Italiana di Fisica Medica
Physica Medica : European Journal of Medical Physics, 24(2), 117-121. Associazione Italiana di Fisica Medica
Griffiths, J A, Metaxas, M G, Pani, S, Schulerud, H, Esbrand, C, Royle, G J, Price, B, Rokvic, T, Longo, R, Asimidis, A, Bletsas, E, Cavouras, D, Fant, A, Gasiorek, P, Georgiou, H, Hall, G, Jones, J, Leaver, J, Li, G, Machin, D, Manthos, N, Matheson, J, Noy, M, Østby, J M, Psomadellis, F, van der Stelt, P F, Theodoridis, S, Triantis, F, Turchetta, R, Venanzi, C & Speller, R D 2008, ' Preliminary images from an adaptive imaging system ', Physica Medica : European Journal of Medical Physics, vol. 24, no. 2, pp. 117-121 . https://doi.org/10.1016/j.ejmp.2008.01.003
Physica Medica : European Journal of Medical Physics, 24(2), 117-121. Associazione Italiana di Fisica Medica
Griffiths, J A, Metaxas, M G, Pani, S, Schulerud, H, Esbrand, C, Royle, G J, Price, B, Rokvic, T, Longo, R, Asimidis, A, Bletsas, E, Cavouras, D, Fant, A, Gasiorek, P, Georgiou, H, Hall, G, Jones, J, Leaver, J, Li, G, Machin, D, Manthos, N, Matheson, J, Noy, M, Østby, J M, Psomadellis, F, van der Stelt, P F, Theodoridis, S, Triantis, F, Turchetta, R, Venanzi, C & Speller, R D 2008, ' Preliminary images from an adaptive imaging system ', Physica Medica : European Journal of Medical Physics, vol. 24, no. 2, pp. 117-121 . https://doi.org/10.1016/j.ejmp.2008.01.003
I-ImaS (Intelligent Imaging Sensors) is a European project aiming to produce real-time adaptive X-ray imaging systems using Monolithic Active Pixel Sensors (MAPS) to create images with maximum diagnostic information within given dose constraints. Ini