Zobrazeno 1 - 10
of 38
pro vyhledávání: '"P. U. Koller"'
Autor:
T. Koschinsky, F. A. Gries, C. Rosak, P. H. Althoff, K. Schöffling, P. Hürter, B. Willms, E. Schumann, H. Regal, J. Zdolsek, K. Irsigler, G. Schernthaner, A. Nakrour, P. U. Koller, K.-D. Willamowski
Publikováno v:
DMW - Deutsche Medizinische Wochenschrift. 109:97-100
Reflocheck, a new microprocessor-regulated apparatus determining blood sugar levels was tested in six laboratories. In the range of 20-450 mg/dl the apparatus gave precise results (co-efficient of variance 0.8%-6.4%), in good agreement with results b
Publikováno v:
DMW - Deutsche Medizinische Wochenschrift. 107:249-251
Screening 720 morning urinary samples for WBC, RBC and protein by test-strip, the number of subsequent microscopic examinations of urinary sediment was reduced to about half, without missing any significant number of clinically significant findings (
Autor:
P. U. Koller, P. Schmidt
Publikováno v:
DMW - Deutsche Medizinische Wochenschrift. 106:458-460
Assessment of the value of test strips for demonstration of white cells in urine (Cytur-test) in 161 out-patient urine samples showed that a quick method such as the Cytur-test is no substitute for conventional methods. In hospital nephrology out-pat
Autor:
R, Leinberger, P U, Koller
Publikováno v:
Scandinavian journal of clinical and laboratory investigation. 51(3)
Publikováno v:
DMW - Deutsche Medizinische Wochenschrift. 104:257-260
Reference values for the revised standard method for determining N-acetylcysteine (NAC) activated creatine kinase (CK) activity in serum are presented, based on samples from 432 out-patients and 423 in-patients of either sex. CK activity was not age-
Publikováno v:
LaboratoriumsMedizin. 13:399-402
Autor:
Y Foo, R Leinberger, S B Rosalki, R Bais, G Weidemann, J Badenoch, H Keller, P M Bayer, P U Koller
Publikováno v:
Clinical Chemistry. 35:317-320
In the Reflotron Amylase dry-reagent carrier system (Boehringer Mannheim GmbH) a new substrate is used for determining total amylase (EC 3.2.1.1) activity:indolyl-alpha-D-maltoheptaoside. The procedure shows low imprecision (median CV less than 3.2%)
Publikováno v:
LaboratoriumsMedizin. 3:71-76
Autor:
P. U. Koller
Publikováno v:
Upsala Journal of Medical Sciences. 91:135-138
Publikováno v:
DMW - Deutsche Medizinische Wochenschrift. 99:343-351
An einer unausgewahlten Population von 2040 Probanden (1075 Manner, 965 Frauen) wurden die Volumenaktivitaten der Enzyme* GOT, GPT und AP entsprechend den Empfehlungen der Deutschen Gesellschaft fur Klinische Chemie bestimmt. Engen Zusammenhang mit d