Zobrazeno 1 - 10
of 22
pro vyhledávání: '"P H, McGinley"'
Autor:
Eileen A. Hebets, Mitch Bern, Rowan H. McGinley, Andy Roberts, Arik Kershenbaum, James Starrett, Jason E. Bond
Publikováno v:
Ecology and Evolution, Vol 11, Iss 2, Pp 852-871 (2021)
Abstract Understanding the relative importance of different sources of selection (e.g., the environment, social/sexual selection) on the divergence or convergence of reproductive communication can shed light on the origin, maintenance, or even disapp
Externí odkaz:
https://doaj.org/article/e912c110d8794859bfe539801b53d6cb
Publikováno v:
PLoS ONE, Vol 12, Iss 10, p e0184940 (2017)
Mating-induced sexual inhibition has been studied extensively as an important facet of many insect mating systems but remains little understood in spiders. Once mated, females of many spider species become unreceptive and aggressive toward males, but
Externí odkaz:
https://doaj.org/article/0125d134b0c04efcac0ad481322c0830
Publikováno v:
Physics in Medicine and Biology. 40:1467-1473
An empirical technique for calculation of the capture gamma ray dose in the maze of high-energy medical accelerators is described. The total photon dose was measured along the maze centre line and by use of a graphical technique the capture gamma dos
Autor:
P H McGinley, E K Butker
Publikováno v:
Physics in Medicine and Biology. 39:1331-1336
In this work the performance of a number of laminated shields used as the primary ceiling barrier for high-energy accelerator rooms was investigated. The neutron and photon dose equivalent rates were measured outside each shield. Based on the measure
Publikováno v:
Medical Physics. 18:806-816
An epithermal neutron filter using iron, aluminum, and sulfur was evaluated to determine if the therapeutic performance could be improved with respect to aluminum--sulfur-based filters. An empirically optimized filter was developed that delivered a 9
Autor:
P H, McGinley
Publikováno v:
Health physics. 80
The author has investigated the use of the inverse square function to predict the photon dose rate outside primary barriers for medical accelerators. Measurements of the dose rate as a function of distance outside the barriers were made at five medic
Publikováno v:
Physics in medicine and biology. 37(2)
Stereotactic radiosurgery utilizing a linear accelerator is now carried out using small non-coplanar beams to produce a high-dose volume that is approximately spherical in shape. It is desirable to shape the high-dose region so that it is similar to
Publikováno v:
Physics in medicine and biology. 35(5)
A new technique for stereotactic radiosurgery by use of a patient rotator is described. Using the rotator with a small collimated beam of 6 MV X-rays, a small well-defined region of the brain can be irradiated to a high dose with rapid fall off of th
Autor:
J C Landry, P H McGinley
Publikováno v:
Physics in Medicine and Biology. 34:777-783
High energy X-ray beams produced by medical accelerators are contaminated with neutrons as a result of photon interactions with the target, flattering filter and collimator. It is important to evaluate the neutron dose to patients undergoing X-ray th
Publikováno v:
Physics in Medicine and Biology. 33:975-980
The neutron flux density outside a lead barrier irradiated by high-energy X-ray beams of various end-point energies was evaluated. The results indicate that replacement of a portion of a concrete radiation barrier with lead at a high-energy medical a