Zobrazeno 1 - 10
of 26
pro vyhledávání: '"Osseointegrated dental implantation"'
Autor:
Guilherme dos Santos Trento, Jaqueline Suemi Hassumi, Paula Buzo Frigério, Ana Paula Farnezi Bassi, Roberta Okamoto, Marisa Aparecida Cabrini Gabrielli, Valfrido Antonio Pereira-Filho
Publikováno v:
International Journal of Implant Dentistry, Vol 6, Iss 1, Pp 1-14 (2020)
Abstract Objective The aim of this study is to evaluate through gene expression, immunohistochemical and microtomographic (micro-CT) analysis the response of peri-implant bone tissue around titanium implants with different surface treatments, placed
Externí odkaz:
https://doaj.org/article/4ebd35c431cc4b58873f77413c18525c
Autor:
Nikola Saulacic, Benoit Schaller
Publikováno v:
eJournal of Oral Maxillofacial Research, Vol 10, Iss 1, p e1 (2019)
Objectives: Moderately-rough implant surface may improve implant therapy in terms of bone integration, but the increased surface roughness might affect the initiation and development of peri-implantitis. The aim of the present review was to compare t
Externí odkaz:
https://doaj.org/article/a3731c8b3e8e4c1a86dc8436e33fa17f
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Roberta Okamoto, Marisa Aparecida Cabrini Gabrielli, Rubens Spin-Neto, Guilherme dos Santos Trento, Valfrido Antonio Pereira-Filho, Ana Paula Farnezi Bassi
Publikováno v:
Web of Science
Repositório Institucional da UNESP
Universidade Estadual Paulista (UNESP)
instacron:UNESP
Trento, G D S, Spin-Neto, R, Bassi, A P F, Okamoto, R, Gabrielli, M A C & Pereira-Filho, V A 2019, ' Bone tissue formation around two titanium implant surfaces placed in bone defects filled with bone substitute material or blood clot; A pilot study ', Clinical Implant Dentistry and Related Research, vol. 21, no. 6, pp. 1175-1180 . https://doi.org/10.1111/cid.12855
Trento, G D S, Spin-Neto, R, Bassi, A P F, Okamoto, R, Gabrielli, M A C & Pereira-Filho, V A 2019, ' Bone tissue formation around two titanium implant surfaces placed in bone defects filled with bone substitute material or blood clot : A pilot study ', Clinical Implant Dentistry and Related Research . https://doi.org/10.1111/cid.12855
Repositório Institucional da UNESP
Universidade Estadual Paulista (UNESP)
instacron:UNESP
Trento, G D S, Spin-Neto, R, Bassi, A P F, Okamoto, R, Gabrielli, M A C & Pereira-Filho, V A 2019, ' Bone tissue formation around two titanium implant surfaces placed in bone defects filled with bone substitute material or blood clot; A pilot study ', Clinical Implant Dentistry and Related Research, vol. 21, no. 6, pp. 1175-1180 . https://doi.org/10.1111/cid.12855
Trento, G D S, Spin-Neto, R, Bassi, A P F, Okamoto, R, Gabrielli, M A C & Pereira-Filho, V A 2019, ' Bone tissue formation around two titanium implant surfaces placed in bone defects filled with bone substitute material or blood clot : A pilot study ', Clinical Implant Dentistry and Related Research . https://doi.org/10.1111/cid.12855
Made available in DSpace on 2020-12-10T19:40:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2019-11-06 Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) ObjectivesThe objective of this study was to evaluate the peri-implant bone
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::707d121b365bcf3174f5b05eb4fac18c
Autor:
Ana Paula F Bassi, Guilherme dos Santos Trento, Erik N R de C Reis, Rubens Spin-Neto, Pedro Henrique de Azambuja Carvalho, Valfrido Antonio Pereira-Filho
Publikováno v:
Web of Science
Repositório Institucional da UNESP
Universidade Estadual Paulista (UNESP)
instacron:UNESP
Trento, G, de A Carvalho, P H, de C Reis, E N R, Spin-Neto, R, Bassi, A P F & Pereira-Filho, V A 2020, ' Bone formation around two titanium implant surfaces placed in bone defects with and without a bone substitute material : A histological, histomorphometric, and micro-computed tomography evaluation ', Clinical Implant Dentistry and Related Research, vol. 22, no. 2, pp. 177-185 . https://doi.org/10.1111/cid.12880
Repositório Institucional da UNESP
Universidade Estadual Paulista (UNESP)
instacron:UNESP
Trento, G, de A Carvalho, P H, de C Reis, E N R, Spin-Neto, R, Bassi, A P F & Pereira-Filho, V A 2020, ' Bone formation around two titanium implant surfaces placed in bone defects with and without a bone substitute material : A histological, histomorphometric, and micro-computed tomography evaluation ', Clinical Implant Dentistry and Related Research, vol. 22, no. 2, pp. 177-185 . https://doi.org/10.1111/cid.12880
Made available in DSpace on 2020-12-10T19:50:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-02-23 Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) Objective To evaluate the histological and microtomographic response of per
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
eJournal of Oral Maxillofacial Research, Vol 2, Iss 4, p e2 (2011)
Journal of Oral & Maxillofacial Research
Journal of Oral & Maxillofacial Research
Objectives The aim of this study was to compare microbiological, histological, and mechanical findings from tissues around osseointergrated dental implants in patients who had undergone tumour resection and subsequent bone grafting with non bone graf
PubMedID: 15355389 Satisfactory dental rehabilitation of dentoalveolar trauma requires intense effort and time. Usually multidisciplinary treatment planning and teamwork are necessary to deal with multitask problems associated with these cases. Denta
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::351df4428e68dc39a96de2e5c67db962
https://hdl.handle.net/20.500.12605/17707
https://hdl.handle.net/20.500.12605/17707