Publikováno v:
Salonen, J, Auerkari, P, Lehtinen, O & Pihkakoski, M 2007, ' Experience on in-service damage in power plant components ', Engineering Failure Analysis, vol. 14, no. 6, pp. 970-977 . https://doi.org/10.1016/j.engfailanal.2006.12.007
Two principal groups of failure mechanisms appear in power plant components. On one hand, each component is usually known to suffer at least potentially from certain failure mechanisms that are expected and largely accounted for in design, manufactur
Autor:
Kari Kolari, Anssi Laukkanen, Olli Lehtinen, Stefan Holmström, Juhani Rantala, Heikki Keinänen
Publikováno v:
Holmström, S, Laukkanen, A, Rantala, J, Kolari, K, Keinänen, H & Lehtinen, O 2008, Modelling and verification of creep strain and exhaustion in a welded steam mixer . in Proceedings of the ASME 2008 Pressure Vessels & Piping Conference, PVP 2008 . vol. 7, American Society of Mechanical Engineers (ASME), New York, NY, pp. 505-510, ASME Pressure Vessels and Piping Conference, PVP 2008, Chicago, Illinois, United States, 27/07/08 . https://doi.org/10.1115/PVP2008-61028
Holmström, S, Rantala, J, Laukkanen, A, Kolari, K, Keinänen, H & Lehtinen, O 2009, ' Modeling and verification of creep strain and exhaustion in a welded steam mixer ', Journal of Pressure Vessel Technology, vol. 131, no. 6, 061405 . https://doi.org/10.1115/1.4000201
Holmström, S, Rantala, J, Laukkanen, A, Kolari, K, Keinänen, H & Lehtinen, O 2009, ' Modeling and verification of creep strain and exhaustion in a welded steam mixer ', Journal of Pressure Vessel Technology, vol. 131, no. 6, 061405 . https://doi.org/10.1115/1.4000201
Structures operating in the creep regime will consume their creep life at a greater rate in locations where the stress state is aggravated by triaxiality constraints. Many structures, such as the welded steam mixer studied here, also have multiple ma
Autor:
Olli Lehtinen, Stefan Holmström, Reino Nikkarila, Jorma Salonen, Pertti Auerkari, Juhani Rantala, Martti Pitkänen
Publikováno v:
VTT Technical Research Centre of Finland-PURE
Rantala, J, Salonen, J, Auerkari, P, Holmström, S, Lehtinen, O, Pitkänen, M & Nikkarila, R 2007, Life extension of hot steam piping after 200 000 h of service . in BALTICA VII-Life Management and Maintenance for Power Plants. Vol. 1 . VTT Technical Research Centre of Finland, Espoo, VTT Symposium, no. 246, pp. 61-69, BALTICA VII-International Conference on Life Management and Main-tenance for Power Plants, Helsinki-Stockholm, Finland, 12/06/07 . < https://publications.vtt.fi/pdf/symposiums/2007/S246.pdf >
Rantala, J, Salonen, J, Auerkari, P, Holmström, S, Lehtinen, O, Pitkänen, M & Nikkarila, R 2007, ' Life extension of hot steam piping after 200 000 h of service ', Energy Materials, vol. 2, no. 2, pp. 104-108 . https://doi.org/10.1179/174892407X266680
Rantala, J, Salonen, J, Auerkari, P, Holmström, S, Lehtinen, O, Pitkänen, M & Nikkarila, R 2007, Life extension of hot steam piping after 200 000 h of service . in BALTICA VII-Life Management and Maintenance for Power Plants. Vol. 1 . VTT Technical Research Centre of Finland, Espoo, VTT Symposium, no. 246, pp. 61-69, BALTICA VII-International Conference on Life Management and Main-tenance for Power Plants, Helsinki-Stockholm, Finland, 12/06/07 . < https://publications.vtt.fi/pdf/symposiums/2007/S246.pdf >
Rantala, J, Salonen, J, Auerkari, P, Holmström, S, Lehtinen, O, Pitkänen, M & Nikkarila, R 2007, ' Life extension of hot steam piping after 200 000 h of service ', Energy Materials, vol. 2, no. 2, pp. 104-108 . https://doi.org/10.1179/174892407X266680
The units 2 and 3 of Naantali power plant have been successfully operated for >200 000 h, and it is of interest to ensure the eligibility of the units for continued production. For this purpose and to assist in the related life assessments, the condi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c494df150c3d2b740285c0400c651fa8
https://cris.vtt.fi/en/publications/da19a26f-5b20-4a84-9241-f9bb04510286
https://cris.vtt.fi/en/publications/da19a26f-5b20-4a84-9241-f9bb04510286
Autor:
Stefan Holmström, Juhani Rantala, Kari Kolari, Heikki Keinänen, Anssi Laukkanen, Juha Veivo, Olli Lehtinen
Publikováno v:
VTT Technical Research Centre of Finland-PURE
Holmström, S, Rantala, J, Kolari, K, Keinänen, H, Laukkanen, A, Veivo, J & Lehtinen, O 2009, Life prediction for a weld repaired steam mixer . in I A Shibli & S R Holdsworth (eds), Proceedings of the 2nd ECCC Creep Conference : Creep & Fracture in High Temperature Components-Design & Life Assessment Issues . DEStech Publications Inc., pp. 309-319, 2nd ECCC Creep Conference, Zurich, Switzerland, 21/04/09 .
Holmström, S, Rantala, J, Kolari, K, Keinänen, H, Laukkanen, A, Veivo, J & Lehtinen, O 2009, Life prediction for a weld repaired steam mixer . in I A Shibli & S R Holdsworth (eds), Proceedings of the 2nd ECCC Creep Conference : Creep & Fracture in High Temperature Components-Design & Life Assessment Issues . DEStech Publications Inc., pp. 309-319, 2nd ECCC Creep Conference, Zurich, Switzerland, 21/04/09 .
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::378aca244717673bf818fea8fc625e5a
https://cris.vtt.fi/en/publications/01fbf696-e476-4c8b-96ca-e493e885652e
https://cris.vtt.fi/en/publications/01fbf696-e476-4c8b-96ca-e493e885652e