Zobrazeno 1 - 10
of 25
pro vyhledávání: '"Olivier Jaubert"'
Autor:
Olivier Jaubert, Michele Pascale, Javier Montalt-Tordera, Julius Akesson, Ruta Virsinskaite, Daniel Knight, Simon Arridge, Jennifer Steeden, Vivek Muthurangu
Publikováno v:
Scientific Reports, Vol 14, Iss 1, Pp 1-10 (2024)
Abstract To develop and assess a deep learning (DL) pipeline to learn dynamic MR image reconstruction from publicly available natural videos (Inter4K). Learning was performed for a range of DL architectures (VarNet, 3D UNet, FastDVDNet) and correspon
Externí odkaz:
https://doaj.org/article/5a7a8d4bd2594e2790bb7d058cc85d40
Publikováno v:
Magnetic Resonance in Medicine. 87:1980-1991
PURPOSE To develop a novel simultaneous co-registered T1 , T2 , T2∗ , T1ρ , and fat fraction abdominal MR fingerprinting (MRF) approach for fully comprehensive liver-tissue characterization in a single breath-hold scan. METHODS A gradient-echo liv
Autor:
Claudia Prieto, Torben Schneider, René M. Botnar, Gastao Cruz, Olivier Jaubert, Thomas Kuestner, Haikun Qi
Publikováno v:
Magnetic Resonance in Medicine. 87:746-763
PURPOSE Develop a novel low-rank motion-corrected (LRMC) reconstruction for nonrigid motion-corrected MR fingerprinting (MRF). METHODS Generalized motion-corrected (MC) reconstructions have been developed for steady-state imaging. Here we extend this
Autor:
Pier Giorgio Masci, Peter Koken, Sohaib Nazir, Reza Hajhosseiny, Daniel Rueckert, Gastao Cruz, Claudia Prieto, René M. Botnar, Olivier Jaubert, Mariya Doneva, Torben Schneider, Aurelien Bustin
Publikováno v:
Journal of Magnetic Resonance Imaging. 53:1253-1265
BACKGROUND Dixon cardiac magnetic resonance fingerprinting (MRF) has been recently introduced to simultaneously provide water T1 , water T2 , and fat fraction (FF) maps. PURPOSE To assess Dixon cardiac MRF repeatability in healthy subjects and its cl
Autor:
Gastao Cruz, Torben Schneider, Cristobal Arrieta, Claudia Prieto, René M. Botnar, Pier Giorgio Masci, Aurelien Bustin, Carlos Sing-Long, Olivier Jaubert, Georgios Georgiopoulos
Publikováno v:
Magnetic Resonance in Medicine. 84:2625-2635
Purpose Quantitative T1 , T2 , T2 *, and fat fraction (FF) maps are promising imaging biomarkers for the assessment of liver disease, however these are usually acquired in sequential scans. Here we propose an extended MR fingerprinting (MRF) framewor
Autor:
Thomas Küstner, Radhouene Neji, Reza Hajhosseiny, René M. Botnar, Aurelien Bustin, Pier Giorgio Masci, Olivier Jaubert, Claudia Prieto
Publikováno v:
Magnetic Resonance in Medicine. 84:2018-2033
Purpose To develop a novel acquisition and reconstruction framework for isotropic 3D Cartesian cardiac CINE within a single breath-hold for left ventricle (LV) and whole-heart coverage. Methods A variable-density Cartesian acquisition with spiral pro
Autor:
Olivier Jaubert, Javier Montalt‐Tordera, James Brown, Daniel Knight, Simon Arridge, Jennifer Steeden, Vivek Muthurangu
Purpose: Real-time monitoring of cardiac output (CO) requires low latency reconstruction and segmentation of real-time phase contrast MR (PCMR), which has previously been difficult to perform. Here we propose a deep learning framework for 'Flow Recon
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7e3b980b69ee3ff6a8e3b7cc0e5a5515
Autor:
Carlos, Velasco, Gastão, Cruz, Olivier, Jaubert, Begoña, Lavin, René M, Botnar, Claudia, Prieto
Publikováno v:
Magnetic resonance in medicineREFERENCES. 87(4)
To develop a novel simultaneous co-registered TA gradient-echo liver MRF sequence with low fixed flip angle, multi-echo radial readout, and varying magnetization preparation pulses for multiparametric encoding is performed at 1.5 T. TheFor the phanto
Autor:
Daniel Rueckert, Begoña Lavin, Torben Schneider, Peter Koken, René M. Botnar, Olivier Jaubert, Gastao Cruz, Reza Hajhosseiny, Aurelien Bustin, Mariya Doneva, Claudia Prieto
Publikováno v:
Magnetic Resonance in Medicine
PURPOSE Cardiac magnetic resonance fingerprinting (cMRF) has been recently introduced to simultaneously provide T1 , T2 , and M0 maps. Here, we develop a 3-point Dixon-cMRF approach to enable simultaneous water specific T1 , T2 , and M0 mapping of th
Autor:
René M. Botnar, Aurelien Bustin, Haikun Qi, Huijun Chen, Olivier Jaubert, Claudia Prieto, Gastao Cruz
Publikováno v:
Magnetic Resonance Imaging. 63:159-169
Purpose To develop a free-running framework for 3D isotropic simultaneous myocardial T1/T2 mapping and cine imaging. Methods Continuous data acquisition with 3D golden angle radial trajectory is used in conjunction with T2 preparation of varying echo