Zobrazeno 1 - 10
of 73
pro vyhledávání: '"Ole, Nähle"'
Autor:
M. Paulsen, Martin Loidl, Christian Enss, J. J. Bonaparte, R. Mariam, P. C.-O. Ranitzsch, Ole Nähle, L. Bockhorn, Karsten Kossert, Jörn Beyer, Sebastian Kempf, M. Wegner, Matias Rodrigues
Publikováno v:
Journal of Low Temperature Physics. 199:451-460
MetroBeta, a recently completed European Metrology Research Project, aimed at the improvement of the knowledge of the shapes of beta spectra, both in terms of theoretical calculation and measurement. The most prominent experimental work package conce
Publikováno v:
EPJ Web of Conferences. 284:02002
In the past two decades, the radionuclide metrology group at PTB has carried out a number of half-life determinations using liquid scintillation counting. The half-lives, which were often determined in collaboration with other institutions, range fro
Autor:
Romain Coulon, Carine Michotte, Sammy Courte, Manuel Nonis, W M van Wyngaardt, Michael L Smith, Angus H H Bowan, Christine M B Keevers, Emily L Clark, Melek Zarifi, Anuradha Ravindra, D B Kulkarni, Ritu Sharma, Marco Capogni, Pierino De Felice, Mauro Capone, Pierluigi Carconi, Aldo Fazio, Christophe Bobin, Paulo A Lima da Cruz, Carlos J da Silva, Ronaldo Lins da Silva, Anderson Leiras, Johnny de Almeida Rangel, Monica Aguiar Leobino da Silva, Akira Iwahara, Denis E Bergeron, Jeffrey T Cessna, Ryan P Fitzgerald, Lizbeth Laureano-Perez, Leticia Pibida, Milton W Van Rooy, Joline Lubbe, Martin J van Staden, Robert Shearman, John Keightley, Andy Pearce, Natasha Ramirez, Emma Bendall, Sean Collins, Tomasz Ziemek, Edyta Lech, Pawel Saganowski, Marek Czudek, Anna Listkowska, Ole Nähle, Karsten Kossert, Marcell P Takács, Matej Krivošík, Ivana Bonková
Publikováno v:
Metrologia. 60:06010
Main text Since 1976, 30 laboratories have submitted 85 samples of 60Co to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)- K1.Co-60. Rec
Autor:
Ole Nähle, Jörn Beyer, Karsten Kossert, M. Paulsen, L. Bockhorn, Martin Loidl, P. C.-O. Ranitzsch, Matias Rodrigues
Publikováno v:
Journal of Low Temperature Physics. 199:298-305
High-resolution beta spectrometry based on low-temperature calorimetric detectors requires high-quality source/absorber combinations in order to avoid spectrum artifacts and to achieve optimal detection efficiency. In this work, preparation technique
Autor:
Karsten Kossert, Ole Nähle
Publikováno v:
Applied Radiation and Isotopes. 145:12-18
Liquid scintillation samples with 227Th were prepared a few hours after the separation of the progeny. During the measurements, 227Th and its daughters are not in radioactive equilibrium. The counting efficiencies of the individual radionuclides of t
Publikováno v:
Astroparticle Physics. 107:22-25
Sturrock et al. have published a “rebuttal” to a paper by Pomme et al. who refuted their claim that variations in a radon decay experiment at the Geological Survey of Israel (GSI) can be associated with solar rotation. Sturrock et al. misinterpre
Autor:
P. De Felice, C Dutsov, Ole Nähle, Philippe Cassette, K Mitev, Eduardo García-Toraño, Youcef Nedjadi, T. Ziemek, Marcell P. Takács, Raphael Galea, A Arinc, P Oropesa Verdecia, Karsten Kossert, Marco Capogni, Juncheng Liang
Publikováno v:
Metrologia
Metrologia, 2020, 57 (1A), pp.06004. ⟨10.1088/0026-1394/57/1A/06004⟩
Metrologia, 2020, 57 (1A), pp.06004. ⟨10.1088/0026-1394/57/1A/06004⟩
A comparison of the activity concentration measurement of a 3H2O solution was organized by the LNE-LNHB under the auspices of the CCRI(II). The solution was sent to thirteen laboratories and eleven measurement reports were received. The results, as w
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::955c7a270a3f8045b24e2bfdaaf63439
https://iopscience.iop.org/article/10.1088/0026-1394/57/1A/06004
https://iopscience.iop.org/article/10.1088/0026-1394/57/1A/06004
Publikováno v:
Applied Radiation and Isotopes. 134:240-244
Germanium-68 is an important radionuclide since it is used to generate its daughter 68Ga which is frequently used for positron emission tomography (PET). In addition, 68Ge/68Ga sources are often used as surrogates for short-lived PET isotopes when ca
Autor:
Ole Nähle
Publikováno v:
Applied Radiation and Isotopes. 134:286-289
The activity of a 67Ga solution was measured by means of the 4πβ-γ coincidence counting technique. A setup with a proportional counter and non-extending dead-time modules in the two detector channels was used. The influence of the delayed state af
Publikováno v:
Applied Radiation and Isotopes
Applied Radiation and Isotopes, 2018, 134 (SI), pp.212-218. ⟨10.1016/j.apradiso.2017.06.015⟩
Applied Radiation and Isotopes, Elsevier, 2018, 134 (SI), pp.212-218. ⟨10.1016/j.apradiso.2017.06.015⟩
Applied Radiation and Isotopes, 2018, 134 (SI), pp.212-218. ⟨10.1016/j.apradiso.2017.06.015⟩
Applied Radiation and Isotopes, Elsevier, 2018, 134 (SI), pp.212-218. ⟨10.1016/j.apradiso.2017.06.015⟩
21st International Conference on Radionuclide Metrology and its Applications (ICRM), Argentinian Comis Nacl Energia Atomica, Buenos Aires, ARGENTINA, MAY 15-19, 2017. Organizer: Argentinian Comision Nacional Energia Atomica; International audience; T