106
Nowadays, the estimation of twin screw compressor performance can be done quickly by using Computation Fluid Dynamics (CFD). A method of 3-D geometry simplification for CFD simulation of a twin-screw compressor has been proposed. In this met
Nowadays, the estimation of twin screw compressor performance can be done quickly by using Computation Fluid Dynamics (CFD). A method of 3-D geometry simplification for CFD simulation of a twin-screw compressor has been proposed. In this met
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/qs4xhf
Publikováno v:
THE INTERNATIONAL CONFERENCE ON ADVANCED MATERIAL AND TECHNOLOGY (ICAMT) 2021.
Autor:
Okasatria Novyanto, Agustinus Praba Drijarkara, Muhammad Azzumar, Istiqomah Istiqomah, Ardi Rahman, Nurul Alfiyati, Asep Hapiddin
Publikováno v:
PROCEEDING OF THE 1ST INTERNATIONAL CONFERENCE ON STANDARDIZATION AND METROLOGY (ICONSTAM) 2021.
Autor:
Eka Pratiwi, Agustinus Praba Drijarkara, Muhammad Azzumar, Asep Ridwan Nugraha, Asep Hapiddin, Nurlathifah Nurlathifah, Istiqomah Istiqomah, Rina Yuniarty, Nurul Alfiyati, Ardi Rahman, Okasatria Novyanto, Gigin Ginanjar, Rudi Anggoro Samodro, Ocka Hedrony
Publikováno v:
Instrumentasi. 45:77
Kesalahan Abbe merupakan salah satu faktor yang mempengaruhi kualitas hasil pengukuran check master . Kesalahan geometri ini dapat direduksi dengan cara melakukan kompensasi, baik secara aktif maupun pasif. Pada penelitian ini, heterodyne laser inter
Publikováno v:
Journal of Physics: Conference Series. 1816:012028
There were no studies that show an acceptable range of calibration factor value on precision surface roughness instruments. It is generally known that the calibration factor plays an essential role in precision surface roughness instruments. This stu
Publikováno v:
Instrumentasi. 44:183
Telah dilakukan studi terkait dua metode kalibrasi untuk menjamin ketertelusuran tekanan statis pada sfigmomanometer non-invasif otomatis. yaitu metode perbandingan langsung dengan akses Test Mode dan metode visual melalui kamera. Metode perbandingan
Publikováno v:
IOP Conference Series: Materials Science and Engineering. 980:012049
The validity of the measurement results can be guaranteed by performing calibration using a measurement standard traced to the international system of units (SI). The linear transducer is a measurement standard that is used to calibrate calibration t
Autor:
Okasatria Novyanto, Nurul Alfiyati
Publikováno v:
MAPAN. 31:9-15
A new method to calibrate the autocollimator with small angle measurement range has been developed. This method used a system based on rotary encoder for angle measurements with self-calibration function (SelfA47). The SelfA47 has 18,000 graduation l
Autor:
Yuke Hary Laksono, Okasatria Novyanto
Publikováno v:
ROTOR. 13:11
A spectral beam splitting concentrated photovoltaic/thermal (SBS CPVT) system is a new technology in PV areas . In order to split the sunlight, the grating lens is used in this study. The tool of this study is G-Solver software which simulates the di