RC precast industrial buildings have recently suffered excessive damage during medium intensity earthquakes, with substantial direct and indirect losses, as highlighted by the seismic events in Northern Italy in May 2012. After an earthquake, the col
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c83d042d3336e98f20c5c91420fabede
http://amsdottorato.unibo.it/8647/
http://amsdottorato.unibo.it/8647/
Publikováno v:
International Journal for Quality Research, Vol 10, Iss 1, Pp 17-46 (2016)
International Journal for Quality Research; Vol 10, No 1, 2016. ISSN 1800-6450
Historical buildings can be highly vulnerable to earthquakes if in-plane strength and stiffness of floors and roofs are not sufficient to limit out-of-plane deformati
Historical buildings can be highly vulnerable to earthquakes if in-plane strength and stiffness of floors and roofs are not sufficient to limit out-of-plane deformati
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::fadd02e6af1e18ea1d2f2ac934721bda
La nota analizza la vulnerabilità sismica di edifici prefabbricati in c.a. utilizzando i dati sui danni raccolti a seguito dei terremoti dell'Emilia del 2012. In particolare, a partire da un inventario relativo a 1421 edifici, corrispondenti a circa
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______4094::aeaa39609dd1f958a2ea339f4ca40afc
http://hdl.handle.net/11585/551223
http://hdl.handle.net/11585/551223
Autor:
ONGARETTO, ELENA, SAVOIA, MARCO
Il presente studio esamina la risposta sismica di strutture prefabbricate in c.a. protette con dissipatori isteretici ad instabilità impedita (BRAD), posizionati esternamente alla struttura esistente e connessi ad un elemento di controvento in c.a.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______4094::6802869822c2226872f192e5237682f3
http://hdl.handle.net/11585/589003
http://hdl.handle.net/11585/589003
The 2012 Emilia (Italy) earthquakes struck a highly industrialized area including several thousands of industrial prefabricated buildings. Due to the lack of specific design and detailing for earthquake resistance, precast reinforced concrete buildin
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______4094::fd084a328855167ae02efa30d7afc546
http://hdl.handle.net/11585/551275
http://hdl.handle.net/11585/551275
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
La sequenza sismica emiliana del 2012 ha investito un’area fortemente industrializzata comprendente alcune migliaia di edifici prefabbricati in c.a. A causa della mancanza di una specifica progettazione nei confronti delle azioni simiche, molti di
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::e8325c00c25d118503baadf519d6fd6f
http://hdl.handle.net/11392/2298416
http://hdl.handle.net/11392/2298416
Intervento di miglioramento sismico di un capannone industriale prefabbricato in c.a. sito in Emilia
La recente sequenza sismica che ha colpito l’Emilia nel Maggio 2012 ha evidenziato con violenza la grande vulnerabilità degli edifici a struttura in c.a. prefabbricata; da qui la necessità di prevedere interventi di miglioramento sismico mirati a
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______4094::dac9924e69b4b953980082fa27d530cc
http://hdl.handle.net/11585/524552
http://hdl.handle.net/11585/524552
The seismic sequence that struck the Emilia region on the 20th and 29th of May 2012 highlighted the high vulnerability of industrial buildings in that area, where precast concrete structures were typically not designed according to seismic criteria,
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______4094::c0f6cf9f6ceffc34a0597eefe2039762
http://hdl.handle.net/11585/395099
http://hdl.handle.net/11585/395099
The 2012 Emilia (Italy) earthquakes hit a highly industrialized area including several thousands of precast RC buildings. Due to the lack of specific design and detailing for earthquake resistance, these buildings suffered from severe damages and eve
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::85dfa889d3b656534fa0a496704bd6b7
http://hdl.handle.net/11392/2218212
http://hdl.handle.net/11392/2218212