Zobrazeno 1 - 10
of 25
pro vyhledávání: '"O.S. Hum"'
Publikováno v:
Journal of Polymer Science: Polymer Symposia. 66:391-398
A static platelet adhesion test using whole human blood was employed to assess the affinity of various bare polymer (sulfonated polystyrene, acetal resin, Teflon FEP, polystyrene) surfaces as well as various surfaces of glass and polymers that were c
Publikováno v:
Thrombosis Research. 7:461-470
Platelet adhesion to smooth solids of different surface tension was investigated by contacting silane coated and uncoated glass slides with a freshly drawn drop of whole blood. Even at short contact times (of the order of 1 second) platelets were obs
Publikováno v:
Thrombosis research. 11(2)
Contact angle measurements with water and platelet adhesion to agar and agarose surfaces are reported. If the gels are allowed to set in contact with different surfaces, gel surfaces with different contact angles are obtained (0° – 56°). Thus it
Publikováno v:
Thrombosis research. 23(3)
The effect of storing platelet suspensions at room temperature before assessing platelet adhesiveness to glass was investigated. Changes found in adhesiveness depended on the albumin concentration of the suspension medium. The initial rate of platele
Publikováno v:
Biomaterials. 2(3)
Platelet adhesion was measured on well-defined smooth surfaces and on the same surfaces with a known amount of roughness, under static conditions and in a new flow cell producing laminar flow. The results obtained with pig platelet suspensions show t
Publikováno v:
Journal of biomedical materials research. 14(4)
Kinetics of platelet adhesion from suspension to various substrates leads to Langmuir isotherm types of curves, both for suspensions in which the platelets were isolated by means of gel filtration as well as by centrifuging and washing. The level of
Publikováno v:
Thrombosis research. 38(2)
Contact angle measurements, histological examinations and platelet adhesion tests on native and glutaraldehyde-treated porcine aortic valve leaflets, are reported. Contact angles measured with water or saline on native and treated leaflets do not dif
Publikováno v:
Biomedizinische Technik/Biomedical Engineering. 21:77-78
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.