Zobrazeno 1 - 7
of 7
pro vyhledávání: '"O. G. Oganesyan"'
Autor:
O. G. Oganesyan, P. M. Ashikova, A. V. Ivanova, K. B. Letnikova, C. O. Oganesyan, P. V. Makarov
Publikováno v:
Российский офтальмологический журнал, Vol 16, Iss 3, Pp 69-74 (2023)
Late complications of radial keratotomy (RK), are as a rule caused by a change in the biomechanical properties of the cornea.Purpose: to study the long-term stabilizing effect of the Bowman’s layer (BL) transplantation after RK.Material and methods
Externí odkaz:
https://doaj.org/article/5b8e6e1a11c24e62bb3cd3e6e072ae24
Publikováno v:
Российский офтальмологический журнал, Vol 14, Iss 2, Pp 59-62 (2021)
Purpose: to evaluate the results of spontaneous non-penetrating keratoprosthesis with a Fedorov — Zuev prosthesis in a patient with severe chemical burns in both eyes. Material and methods.Patient K., 38, who had sustained a severe burn injury in t
Externí odkaz:
https://doaj.org/article/adf1ee41dfec4c8faffef9365e0f1b2f
Publikováno v:
Российский офтальмологический журнал, Vol 12, Iss 4, Pp 43-50 (2019)
Purpose: to study the efficiency of Bowman layer transplantation (BLT) in corneal stroma for the treatment of progressive keratoconus (KC).Material and methods. 30 patients (30 eyes) with progressive KC stages III to IV (according to Amsler — Krume
Externí odkaz:
https://doaj.org/article/e538a06763ea4e5ca2795feaf983101f
Publikováno v:
Российский офтальмологический журнал, Vol 11, Iss 3, Pp 11-18 (2018)
Purpose: to report the first case of the same day use of a single donor cornea tissue for 5 consecutive transplantations in patients with endothelial dystrophy and keratoconus. Material and methods. The Descemet membrane (DM) and the endothelium were
Externí odkaz:
https://doaj.org/article/1738b35e7f5d4d1690362fa598139407
Publikováno v:
Российский офтальмологический журнал, Vol 10, Iss 3, Pp 102-106 (2018)
Purpose: to study the results of toric intraocular correction following a surgical treatment of cataract in a 69-year-old patient with the 2nd stage of keratoconus by Amsler-Krumeich classification with intrastromal corneal segments implanted. Method
Externí odkaz:
https://doaj.org/article/4d4c090acef54b4a9757460ba1884fa8
Publikováno v:
Российский офтальмологический журнал, Vol 10, Iss 2, Pp 47-53 (2018)
Purpose: to compare clinical, functional and morphological results of treatment of progressing keratoconus by femtosecond, trans-epithelial and standard corneal collagen crosslinking. Material and methods. 114 patients aged 18-35 (148 eyes) with prog
Externí odkaz:
https://doaj.org/article/de8eb7ca8b4c4c1e8882274e5fa30f13
Publikováno v:
Russian Pediatric Ophthalmology. 12:35-42
Optical biometry is based on the laser interferometry technique for the measurement of the biometric characteristics of the eyes, such as the antero-posterior axial length, anterior chamber depth, lens and retina thickness, corneal diameter and param