Zobrazeno 1 - 10
of 20
pro vyhledávání: '"O M, Böstman"'
Autor:
O. M. Böstman
♦ Use of absorbable fracture fixation devices eliminates hardware removal procedures♦ Of the macromolecular biodegradable compounds, suited for the manufacturing of these implants, polylactide is the most widely used♦ Small-fragment intra-artic
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::18ae21e4345cde7996cb0a0d62a3483a
https://doi.org/10.1093/med/9780199550647.003.012016
https://doi.org/10.1093/med/9780199550647.003.012016
Autor:
O M Böstman
Publikováno v:
The Journal of Bone & Joint Surgery. 73:148-153
Autor:
O M Böstman
Publikováno v:
The Journal of Bone & Joint Surgery. 72:1013-1018
Of 103 patients who had a fracture of the distal third of the femur that was treated by open reduction and internal fixation with a condylar blade-plate, sixty-two had removal of the plate after the fracture had united. The mean interval between inju
Autor:
O M, Böstman, H K, Pihlajamäki
Publikováno v:
Clinical orthopaedics and related research. (371)
Among 2528 patients operated on using pins, rods, bolts, and screws made of polyglycolic acid or polylactic acid, 108 (4.3%) were affected by a clinically significant local inflammatory, sterile tissue reaction. The three most common indications for
Autor:
O M, Böstman
Publikováno v:
The Journal of bone and joint surgery. British volume. 80(2)
Between 1985 and 1994, 1223 patients with malleolar fractures of the ankle were treated by open reduction and internal fixation with absorbable pins and screws, of whom 74 (6.1%) had an obvious inflammatory foreign-body reaction to the implants. Of t
Autor:
O M, Böstman
Publikováno v:
Clinical orthopaedics and related research. (329)
Absorbable polyester pins and screws for the internal fixation of small fragment fractures have been commercially available for several years. The main advantage of these devices is that no implant removal procedures are required, which could result
Publikováno v:
Clinical orthopaedics and related research. (320)
The clinical biocompatibility and degradation behavior of absorbable fracture fixation devices are still incompletely known in humans. Fifty-one patients with displaced fracture of the ankle treated by open reduction and internal fixation with absorb
Autor:
O M, Böstman
Publikováno v:
The Journal of bone and joint surgery. British volume. 77(1)
A series of 3061 patients with fracture of the distal tibia or ankle was studied for a possible link between overweight and failed reduction. The relative body-weight was recorded as the preoperative self-reported body mass index (BMI) of each patien
Autor:
O M, Böstman
Publikováno v:
International journal of obesity and related metabolic disorders : journal of the International Association for the Study of Obesity. 18(10)
The aim of this work was to test the hypothesis that obesity is more common among patients requiring elective orthopaedic surgery than in the general population. A cross-sectional survey was carried out on 2673 consecutive patients admitted from the
Publikováno v:
Clinical orthopaedics and related research. (285)
A transverse transcondylar osteotomy of the distal femur was fixed with an axially placed absorbable fracture fixation screw made of polyglycolide (PGA) in 25 rabbits. Changes at the tissue-implant interface accompanying degradation of the screw were