Zobrazeno 1 - 10
of 20
pro vyhledávání: '"Nucleus disassembly"'
Autor:
Jeremy Jones, Aditya Rali, Maria Aaron, Timothy Grosel, Elliot Moore, Jerry Fontus, Yousuf M. Khalifa
Publikováno v:
Journal of Cataract and Refractive Surgery. 48:44-50
PURPOSE To assess the phacoemulsification learning curve for ophthalmology residents using duration for each step. SETTING Single tertiary, training site hospital. DESIGN Cross sectional study examining duration of cataract surgery steps as a functio
Publikováno v:
Journal of Cataract and Refractive Surgery. 46:1515-1521
PURPOSE To evaluate the refractive impact of centripetal fragmentation using the miLOOP system for nucleus disassembly, which minimizes lens zonulocapsular instability associated with endocapsular lens manipulation. SETTING Private practice, Batesvil
Autor:
Khalid Al-Arfaj, Ammar Al Mahmood, Abdullah Almarshood, Mohanna Y. Al-Jindan, Sanaa A. Yassin, Naif M Sulaimani
Publikováno v:
Clinical Ophthalmology. 14:113-118
Purpose To assess residents' performance of phacoemulsification surgery and determine which steps of the procedure are most difficult to learn, and to measure rate of intraoperative complications. Design This was a prospective observational study. Me
Publikováno v:
Clinical Ophthalmology (Auckland, N.Z.)
Ahmed H Assaf,1,2 Mohamed G Aly,1 Rania G Zaki,1 Yasmine M Shaaban,1 Bassem F Aziz1,2 1Ain Shams University, Faculty of Medicine, Ophthalmology Department, Cairo, Egypt; 2Al Watany Eye Hospital, Cataract and Refractive Department, Cairo, EgyptCorresp
Publikováno v:
Retina (Philadelphia, Pa.).
Purpose To describe a novel technique of lens disassembly in posteriorly dislocated crystalline lens removal. Methods A microinterventional microfilament loop device (miLOOP) was introduced through the sclerotomy created for the Fragmatome to cleave
Publikováno v:
Acta ophthalmologicaReferences. 99(3)
Purpose To quantify the intraoperative parameters and postoperative outcomes after using the phaco chop technique in one eye and drill-and-crack technique in the other eye in patients with bilateral dense brunescent cataract. Methods The Lens Opaciti
Autor:
Elliot Moore, Aditya Rali, Laura Ward, Maria Aaron, Yousuf M. Khalifa, Jerry Fontus, Jeremy Jones
Publikováno v:
Journal of Academic Ophthalmology, Vol 10, Iss 01, Pp e179-e184 (2018)
Purpose To investigate intraoperative stress levels using heart rate monitoring during each step of cataract surgery. Setting Single tertiary hospital. Design Observational study recording resident heart rate as a measure of acute stress level during
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Robert J Weinstock, Neel R. Desai, Alexander J Weinstock, Brittany N Cook, Vasilios F. Diakonis
Publikováno v:
European journal of ophthalmology. 28(4)
Purpose: To describe a novel mechanical endocapsular fragmentation technique of the crystalline lens during cataract surgery using a loop elastic-thin filament. Methods: An alternative method to mechanically fragment the crystalline lens utilizing a
Autor:
Farrell Toby Tyson, Iqbal Ike K. Ahmed, David F. Chang, Susan M. MacDonald, Tsontcho Ianchulev, Andrea Vasquez, Edward H. Koo, Ernesto Calvo
Publikováno v:
The British Journal of Ophthalmology
AimTo assess the safety and efficacy of microinterventional endocapsular nuclear fragmentation in moderate to severe cataracts.MethodsThis was a prospective single-masked multisurgeon interventional randomised controlled trial (ClinicalTrials.govNCT0