Zobrazeno 1 - 10
of 53
pro vyhledávání: '"Norman F. Sheppard"'
Publikováno v:
Biotechnology and Bioengineering. 75:475-484
In this article, we describe the use of pH- responsive hydrogels as matrices for the immobilization of two enzymes, glucose oxidase (GOx) and glutamate oxidase (GlutOx). Spherical hydrogel beads were prepared by inverse suspension polymerization and
Publikováno v:
Analytical Chemistry. 71:4669-4678
This paper describes a microfluidic system in which fluids are pumped by centrifugal force through microscopic channels defined in a plastic disk in order to perform complex analytical processes. The channels are created either by casting poly(dimeth
Autor:
Norman F. Sheppard, Matthew J. Lesho
Publikováno v:
Polymer Gels and Networks. 5:503-523
A novel method was applied to the study of swelling kinetics of pH-responsive hydrogels. This technique is based on the pH-dependent electrical conductivity of these materials, which is measured by coating planar interdigitated electrode arrays with
Autor:
Asaf Keller, Lee A. Zimmer, Sergey Yagodin, Vassiliki Aroniadou-Anderjaska, Norman F. Sheppard, Michael T. Shipley, Matthew Ennis
Publikováno v:
The Journal of Neuroscience. 18:2602-2612
The functional organization and synaptic physiology of olfactory bulb glomeruli were studied in ratin vitroslice preparations stained with the voltage-sensitive dye RH-155. Optical signals were recorded with a 100-element photodiode array at high tem
Autor:
Norman F. Sheppard, Matthew J. Lesho
Publikováno v:
Sensors and Actuators B: Chemical. 37:61-66
The use of a silane coupling agent, γ-methacryloxypropyl trimethoxysilane (γ-MPS), to promote adhesion of photolithographically patterned polymer hydrogels to oxidized silicon wafers and conductometric sensors has been examined. Poly-(hydroxyethyl
Publikováno v:
Journal of Controlled Release. 42:15-24
Physical models of polymer matrix controlled release systems were constructed by using silicon micromachining to fabricate miniature pore networks having features comparable in size to those found in the polymer systems. The networks were formed from
Publikováno v:
Biosensors and Bioelectronics. 11:967-979
A model for predicting the response of a conductimetric urea biosensor was developed and validated experimentally. The biosensor under consideration is formed by immobilizing the enzyme urease onto the surface of a planar interdigitated electrode arr
Publikováno v:
Sensors and Actuators B: Chemical. 28:95-102
A miniature conductimetric pH sensor has been developed, based on the measurement of the conductivity of a pH-responsive hydrogel. The microfabricated sensor is constructed by coating planar interdigitated electrode arrays with a photolithographicall
Autor:
Laura McCabe, Michael J. Cima, John T. Santini, James M. Anderson, Norman F. Sheppard, Robert Langer, Robert Farra, Robert M. Neer
Publikováno v:
Science Translational Medicine. 4
The first clinical trial of an implantable microchip-based drug delivery device is discussed. Human parathyroid hormone fragment (1-34) [hPTH(1-34)] was delivered from the device in vivo. hPTH(1-34) is the only approved anabolic osteoporosis treatmen
Autor:
Richard B. Dause, W. Mark Saltzman, J. Alan Pratt, Amy M. Dodrill, Norman F. Sheppard, Mark A. McHugh
Publikováno v:
Journal of Applied Polymer Science. 48:1493-1500
A new method is presented for controlling the rate of antibody (Ab) release from an inert matrix composed of poly(ethylene-co-vinyl acetate) (EVAc), a biocompatible polymer that is frequently used to achieve controlled release. Using supercritical pr