Zobrazeno 1 - 10
of 77
pro vyhledávání: '"Nobuo, MISAWA"'
Publikováno v:
Sensors, Vol 23, Iss 5, p 2370 (2023)
We report on a compact two-electrode voltage clamping system composed of microfabricated electrodes and a fluidic device for Xenopus laevis oocytes. The device was fabricated by assembling Si-based electrode chips and acrylic frames to form fluidic c
Externí odkaz:
https://doaj.org/article/bd1b9917ca094066a73347df1feac965
Publikováno v:
Micromachines, Vol 12, Iss 1, p 53 (2021)
This paper describes a method for a bilayer lipid membrane (BLM) formation using a perforated sheet along with an open chamber. Microscopic observation of the formed membrane showed a typical droplet interface bilayer. We proved that the formed membr
Externí odkaz:
https://doaj.org/article/875bc9859c8f41ffab8d6561e41caccb
Publikováno v:
Journal of Japan Association on Odor Environment. 53:3-16
Autor:
Yoshihisa Ito, Yusuke Izawa, Toshihisa Osaki, Koki Kamiya, Nobuo Misawa, Satoshi Fujii, Hisatoshi Mimura, Norihisa Miki, Shoji Takeuchi
Publikováno v:
Micromachines, Vol 11, Iss 12, p 1123 (2020)
Lipid-bilayer devices have been studied for on-site sensors in the fields of diagnosis, food and environmental monitoring, and safety/security inspection. In this paper, we propose a lipid-bilayer-on-a-cup device for serial sample measurements using
Externí odkaz:
https://doaj.org/article/fcf44e146f4247deb09e6af9df76a570
Autor:
Koki Kamiya, Toshihisa Osaki, Satoshi Fujii, Nobuo Misawa, Shoji Takeuchi, Masatoshi Hayakawa
Publikováno v:
Analytical Chemistry. 90:10217-10222
MicroRNAs have critical roles in a number of serious diseases and, as a result, are of major interest as clinical diagnostic targets. Conventionally, microRNAs are collected from blood and urine samples and are measured by either quantitative reverse
Sequential generation of asymmetric lipid vesicles using a pulsed-jetting method in rotational wells
Autor:
Nobuo Misawa, Norihisa Miki, Satoshi Fujii, Masahide Gotanda, Koki Kamiya, Shoji Takeuchi, Toshihisa Osaki
Publikováno v:
Sensors and Actuators B: Chemical. 261:392-397
Current methods of generating asymmetric lipid vesicles produce only single types of vesicles, which poses a challenge for investigation of vesicles with different lipid leaflet combinations using a single device. Here, we describe a device for seque
Autor:
Shoji Takeuchi, Koki Kamiya, Toshihisa Osaki, Yusuke Izawa, Norihisa Miki, Nobuo Misawa, Satoshi Fujii
Publikováno v:
Sensors and Actuators B: Chemical. 258:1036-1041
Sloshing is the movement of liquid in a container induced by an external force. The phenomenon has been extensively studied at the macroscopic scale because of the importance of liquid control in tanks. Sloshing at the microliter scale should be expl
Autor:
Yong Joon Choi, Tatsuya Iwata, Takeshi Hizawa, Nobuo Misawa, Kazuaki Sawada, Kazuhiro Takahashi
Publikováno v:
Sensors and Actuators B: Chemical. 256:38-47
In this paper, we report on the development of a filter-free fluorescence sensor for the detection of multiple fluorescence wavelengths from a solution of fluorescent dyes with submicromolar concentrations. The filter-free fluorescence sensor has a p
Autor:
Yuji Sukekawa, Takamichi Nakamoto, Totok Mujiono, Yuko Nakajima, Nobuo Misawa, Ryohei Kanzaki, Hidefumi Mitsuno
Publikováno v:
Electronics and Communications in Japan. 100:41-49
Autor:
Satoshi Fujii, Koki Kamiya, Tomoyuki Takaku, Yasuhiko Takahashi, Shoji Takeuchi, Toshihisa Osaki, Nobuo Misawa
Publikováno v:
ACS sensors. 4(3)
This paper describes an odorant sensor based on mosquito olfactory receptors (ORs) that is sensitive to the volatile organic compound octenol. The ORs and OR coreceptors were reconstructed in the lipid bilayer membrane in a chamber device equipped wi