Zobrazeno 1 - 10
of 1 035
pro vyhledávání: '"Nisi S."'
Autor:
Avignone III, F. T., Barabash, A. S., Berest, V., Bergé, L., Calvo-Mozota, J. M., Carniti, P., Chapellier, M., Dafinei, I., Danevich, F. A., Dumoulin, L., Ferella, F., Ferri, F., Gallas, A., Giuliani, A., Gotti, C., Gras, P., Ianni, A., Imbert, L., Khalife, H., Kobychev, V. V., Konovalov, S. I., Loaiza, P., de Marcillac, P., Marnieros, S., Marrache-Kikuchi, C. A., Martinez, M., Nisi, S., Nones, C., Olivieri, E., de Solórzano, A. Ortiz, Peinaud, Y., Pessina, G., Poda, D. V., Rosier, Ph., Scarpaci, J. A., Tretyak, V. I., Umatov, V. I., Zarytskyy, M. M., Zolotarova, A.
We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in $^{130}$Te to about 91%, for the CROSS double-beta decay experiment. A powder used for the crystals growt
Externí odkaz:
http://arxiv.org/abs/2406.01444
Autor:
XENON Collaboration, Aprile, E., Aalbers, J., Abe, K., Maouloud, S. Ahmed, Althueser, L., Andrieu, B., Angelino, E., Angevaare, J. R., Antochi, V. C., Martin, D. Antón, Arneodo, F., Balata, M., Baudis, L., Baxter, A. L., Bazyk, M., Bellagamba, L., Biondi, R., Bismark, A., Brookes, E. J., Brown, A., Bruenner, S., Bruno, G., Budnik, R., Bui, T. K., Cai, C., Cardoso, J. M. R., Cassese, F., Chiarini, A., Cichon, D., Chavez, A. P. Cimental, Colijn, A. P., Conrad, J., Corrieri, R., Cuenca-García, J. J., Cussonneau, J. P., Dadoun, O., D'Andrea, V., Decowski, M. P., De Fazio, B., Di Gangi, P., Diglio, S., Disdier, J. M., Douillet, D., Eitel, K., Elykov, A., Farrell, S., Ferella, A. D., Ferrari, C., Fischer, H., Flierman, M., Form, S., Front, D., Fulgione, W., Fuselli, C., Gaemers, P., Gaior, R., Rosso, A. Gallo, Galloway, M., Gao, F., Gardner, R., Garroum, N., Glade-Beucke, R., Grandi, L., Grigat, J., Guan, H., Guerzoni, M., Guida, M., Hammann, R., Higuera, A., Hils, C., Hoetzsch, L., Hood, N. F., Howlett, J., Huhmann, C., Iacovacci, M., Iaquaniello, G., Iven, L., Itow, Y., Jakob, J., Joerg, F., Joy, A., Kara, M., Kavrigin, P., Kazama, S., Kobayashi, M., Koltman, G., Kopec, A., Kuger, F., Landsman, H., Lang, R. F., Levinson, L., Li, I., Li, S., Liang, S., Lindemann, S., Lindner, M., Liu, K., Loizeau, J., Lombardi, F., Long, J., Lopes, J. A. M., Ma, Y., Macolino, C., Mahlstedt, J., Mancuso, A., Manenti, L., Marignetti, F., Undagoitia, T. Marrodán, Martella, P., Martens, K., Masbou, J., Masson, D., Masson, E., Mastroianni, S., Mele, E., Messina, M., Michinelli, R., Miuchi, K., Molinario, A., Moriyama, S., Morå, K., Mosbacher, Y., Murra, M., Müller, J., Ni, K., Nisi, S., Oberlack, U., Orlandi, D., Othegraven, R., Paetsch, B., Palacio, J., Parlati, S., Paschos, P., Pellegrini, Q., Peres, R., Peters, C., Pienaar, J., Pierre, M., Plante, G., Pollmann, T. R., Qi, J., Qin, J., García, D. Ramírez, Rynge, M., Shi, J., Singh, R., Sanchez, L., Santos, J. M. F. dos, Sarnoff, I., Sartorelli, G., Schreiner, J., Schulte, D., Schulte, P., Eißing, H. Schulze, Schumann, M., Lavina, L. Scotto, Selvi, M., Semeria, F., Shagin, P., Shi, S., Shockley, E., Silva, M., Simgen, H., Stephen, J., Stern, M., Stillwell, B. K., Takeda, A., Tan, P. -L., Tatananni, D., Terliuk, A., Thers, D., Toschi, F., Trinchero, G., Tunnell, C., Tönnies, F., Valerius, K., Volta, G., Weinheimer, C., Weiss, M., Wenz, D., Westermann, J., Wittweg, C., Wolf, T., Wu, V. H. S., Xing, Y., Xu, D., Xu, Z., Yamashita, M., Yang, L., Ye, J., Yuan, L., Zavattini, G., Zhong, M., Zhu, T.
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the progra
Externí odkaz:
http://arxiv.org/abs/2402.10446
Autor:
Angloher, G., Banik, S., Benato, G., Bento, A., Bertolini, A., Breier, R., Bucci, C., Burkhart, J., Canonica, L., D'Addabbo, A., Di Lorenzo, S., Einfalt, L., Erb, A., Feilitzsch, F. v., Fichtinger, S., Fuchs, D., Garai, A., Ghete, V. M., Gorla, P., Guillaumon, P. V., Gupta, S., Hauff, D., Jeskovsky, M., Jochum, J., Kaznacheeva, M., Kinast, A., Kluck, H., Kraus, H., Kuckuk, S., Langenkaemper, A., Mancuso, M., Marini, L., Meyer, L., Mokina, V., Nilima, A., Olmi, M., Ortmann, T., Pagliarone, C., Pattavina, L., Petricca, F., Potzel, W., Povinec, P., Proebst, F., Pucci, F., Reindl, F., Rothe, J., Schaeffner, K., Schieck, J., Schmiedmayer, D., Schoenert, S., Schwertner, C., Stahlberg, M., Stodolsky, L., Strandhagen, C., Strauss, R., Usherov, I., Wagner, F., Willers, M., Zema, V., Ferella, F., Laubenstein, M., Nisi, S.
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate backgr
Externí odkaz:
http://arxiv.org/abs/2307.12991
Autor:
Azzolini, O., Beeman, J. W., Bellini, F., Beretta, M., Biassoni, M., Brofferio, C., Bucci, C., Capelli, S., Caracciolo, V., Cardani, L., Carniti, P., Casali, N., Celi, E., Chiesa, D., Clemenza, M., Colantoni, I., Cremonesi, O., Cruciani, A., D'Addabbo, A., Dafinei, I., Di Domizio, S., Dompè, V., Fantini, G., Ferroni, F., Gironi, L., Giuliani, A., Gorla, P., Gotti, C., Keppel, G., Kotila, J., Martinez, M., Nagorny, S. S., Nastasi, M., Nisi, S., Nones, C., Orlandi, D., Pagnanini, L., Pallavicini, M., Pattavina, L., Pavan, M., Pessina, G., Pettinacci, V., Pirro, S., Pozzi, S., Previtali, E., Puiu, A., Ressa, A., Rusconi, C., Schäffner, K., Tomei, C., Vignati, M., Zolotarova, A. S.
We report on the results obtained with the global CUPID-0 background model, which combines the data collected in the two measurement campaigns for a total exposure of 16.6 kg$\times$yr. We identify with improved precision the background sources in th
Externí odkaz:
http://arxiv.org/abs/2306.14654
Autor:
Cerroni, R., Dell'Oro, S., Formicola, A., Ghislandi, S., Ioannucci, L., Laubenstein, M., Lehnert, B., Nagorny, S. S., Nisi, S., Pagnanini, L.
Publikováno v:
Eur. Phys. J. C 83, 925 (2023)
$^{180m}$Ta is the longest-lived metastable state presently known. Its decay has not been observed yet. In this work, we report a new result on the decay of \mTa obtained with a $2015.12$-g tantalum sample measured for $527.7$ d with an ultra-low bac
Externí odkaz:
http://arxiv.org/abs/2305.17238
Autor:
Armatol, A., Broerman, B., Dumoulin, L., Giuliani, A., Khalife, H., Laubenstein, M., Loaiza, P., de Marcillac, P., Marnieros, S., Nagorny, S. S., Nisi, S., Nones, C., Olivieri, E., Pagnanini, L., Pirro, S., Poda, D. V., Scarpaci, J. -A., Zolotarova, A. S.
The first detailed study on the performance of a ZnO-based cryogenic scintillating bolometer as a detector to search for rare processes in zinc isotopes was performed. A 7.2 g ZnO low-temperature detector, containing more than 80\% of zinc in its mas
Externí odkaz:
http://arxiv.org/abs/2304.05043
Autor:
CUPID collaboration, Alfonso, K., Armatol, A., Augier, C., Avignone III, F. T., Azzolini, O., Balata, M., Barabash, A. S., Bari, G., Barresi, A., Baudin, D., Bellini, F., Benato, G., Berest, V., Beretta, M., Bettelli, M., Biassoni, M., Billard, J., Boldrini, V., Branca, A., Brofferio, C., Bucci, C., Camilleri, J., Campani, A., Capelli, C., Capelli, S., Cappelli, L., Cardani, L., Carniti, P., Casali, N., Celi, E., Chang, C., Chiesa, D., Clemenza, M., Colantoni, I., Copello, S., Craft, E., Cremonesi, O., Creswick, R. J., Cruciani, A., D'Addabbo, A., D'Imperio, G., Dabagov, S., Dafinei, I., Danevich, F. A., De Jesus, M., de Marcillac, P., Dell'Oro, S., Di Domizio, S., Di Lorenzo, S., Dixon, T., Dompé, V., Drobizhev, A., Dumoulin, L., Fantini, G., Faverzani, M., Ferri, E., Ferri, F., Ferroni, F., Figueroa-Feliciano, E., Foggetta, L., Formaggio, J., Franceschi, A., Fu, C., Fu, S., Fujikawa, B. K., Gallas, A., Gascon, J., Ghislandi, S., Giachero, A., Gianvecchio, A., Girola, M., Gironi, L., Giuliani, A., Gorla, P., Gotti, C., Grant, C., Gras, P., Guillaumon, P. V., Gutierrez, T. D., Han, K., Hansen, E. V., Heeger, K. M., Helis, D. L., Huang, H. Z., Imbert, L., Johnston, J., Juillard, A., Karapetrov, G., Keppel, G., Khalife, H., Kobychev, V. V., Kolomensky, Yu. G., Konovalov, S. I., Kowalski, R., Langford, T., Lefevre, M., Liu, R., Liu, Y., Loaiza, P., Ma, L., Madhukuttan, M., Mancarella, F., Marini, L., Marnieros, S., Martinez, M., Maruyama, R. H., Mas, Ph., Mayer, D., Mazzitelli, G., Mei, Y., Milana, S., Morganti, S., Napolitano, T., Nastasi, M., Nikkel, J., Nisi, S., Nones, C., Norman, E. B., Novosad, V., Nutini, I., O'Donnell, T., Olivieri, E., Olmi, M., Ouellet, J. L., Pagan, S., Pagliarone, C., Pagnanini, L., Pattavina, L., Pavan, M., Peng, H., Pessina, G., Pettinacci, V., Pira, C., Pirro, S., Poda, D. V., Polischuk, O. G., Ponce, I., Pozzi, S., Previtali, E., Puiu, A., Quitadamo, S., Ressa, A., Rizzoli, R., Rosenfeld, C., Rosier, P., Scarpaci, J. A., Schmidt, B., Sharma, V., Shlegel, V. N., Singh, V., Sisti, M., Slocum, P., Speller, D., Surukuchi, P. T., Taffarello, L., Tomei, C., Torres, J. A., Tretyak, V. I., Tsymbaliuk, A., Velazquez, M., Vetter, K. J., Wagaarachchi, S. L., Wang, G., Wang, L., Wang, R., Welliver, B., Wilson, J., Wilson, K., Winslow, L. A., Xue, M., Yan, L., Yang, J., Yefremenko, V., Umatov, V. I., Zarytskyy, M. M., Zhang, J., Zolotarova, A., Zucchelli, S.
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for t
Externí odkaz:
http://arxiv.org/abs/2304.04674
Autor:
CUPID, collaborations, CROSS, Alfonso, K., Armatol, A., Augier, C., Avignone III, F. T., Azzolini, O., Balata, M., Bandac, I. C., Barabash, A. S., Bari, G., Barresi, A., Baudin, D., Bellini, F., Benato, G., Berest, V., Beretta, M., Bettelli, M., Biassoni, M., Billard, J., Boldrini, V., Branca, A., Brofferio, C., Bucci, C., Calvo-Mozota, J. M., Camilleri, J., Campani, A., Capelli, C., Capelli, S., Cappelli, L., Cardani, L., Carniti, P., Casali, N., Celi, E., Chang, C., Chiesa, D., Clemenza, M., Colantoni, I., Copello, S., Craft, E., Cremonesi, O., Creswick, R. J., Cruciani, A., D'Addabbo, A., D'Imperio, G., Dabagov, S., Dafinei, I., Danevich, F. A., De Jesus, M., de Marcillac, P., Dell'Oro, S., Di Domizio, S., Di Lorenzo, S., Dixon, T., Dompé, V., Drobizhev, A., Dumoulin, L., Fantini, G., Faverzani, M., Ferri, E., Ferri, F., Ferroni, F., Figueroa-Feliciano, E., Foggetta, L., Formaggio, J., Franceschi, A., Fu, C., Fu, S., Fujikawa, B. K., Gallas, A., Gascon, J., Ghislandi, S., Giachero, A., Gianvecchio, A., Girola, M., Gironi, L., Giuliani, A., Gorla, P., Gotti, C., Grant, C., Gras, P., Guillaumon, P. V., Gutierrez, T. D., Han, K., Hansen, E. V., Heeger, K. M., Helis, D. L., Huang, H. Z., Ianni, A., Imbert, L., Johnston, J., Juillard, A., Karapetrov, G., Keppel, G., Khalife, H., Kobychev, V. V., Kolomensky, Yu. G., Konovalov, S. I., Kowalski, R., Langford, T., Lefevre, M., Liu, R., Liu, Y., Loaiza, P., Ma, L., Madhukuttan, M., Mancarella, F., Marrache-Kikuchi, C. A., Marini, L., Marnieros, S., Martinez, M., Maruyama, R. H., Mas, Ph., Mayer, D., Mazzitelli, G., Mei, Y., Milana, S., Morganti, S., Napolitano, T., Nastasi, M., Nikkel, J., Nisi, S., Nones, C., Norman, E. B., Novosad, V., Nutini, I., O'Donnell, T., Olivieri, E., Olmi, M., Ouellet, J. L., Pagan, S., Pagliarone, C., Pagnanini, L., Pattavina, L., Pavan, M., Peng, H., Pessina, G., Pettinacci, V., Pira, C., Pirro, S., Poda, D. V., Polischuk, O. G., Ponce, I., Pozzi, S., Previtali, E., Puiu, A., Quitadamo, S., Ressa, A., Rizzoli, R., Rosenfeld, C., Rosier, P., Scarpaci, J. A., Schmidt, B., Sharma, V., Shlegel, V. N., Singh, V., Sisti, M., Slocum, P., Speller, D., Surukuchi, P. T., Taffarello, L., Tomei, C., Torres, J. A., Tretyak, V. I., Tsymbaliuk, A., Velazquez, M., Vetter, K. J., Wagaarachchi, S. L., Wang, G., Wang, L., Wang, R., Welliver, B., Wilson, J., Wilson, K., Winslow, L. A., Xue, M., Yan, L., Yang, J., Yefremenko, V., Umatov, V. I., Zarytskyy, M. M., Zhang, J., Zolotarova, A., Zucchelli, S.
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested i
Externí odkaz:
http://arxiv.org/abs/2304.04611
A search for rare decays of gadolinium isotopes was performed with an ultra-low background high-purity germanium detector at Gran Sasso Underground Laboratory (Italy). A 198 g Gd$_2$O$_3$ powder sample was measured for 63.8 d with a total Gd exposure
Externí odkaz:
http://arxiv.org/abs/2302.06131
A 510 day long-term measurement of a 45.3 g platinum foil acting as the sample and high voltage contact in an ultra-low-background high purity germanium detector was performed at Laboratori Nazionali del Gran Sasso (Italy). The data was used for a de
Externí odkaz:
http://arxiv.org/abs/2209.11106