Zobrazeno 1 - 10
of 15
pro vyhledávání: '"Niki, Fitousi"'
Publikováno v:
Frontiers in Physics, Vol 12 (2024)
IntroductionChest radiography is a frequently performed examination, and therefore, accurate patient dosimetry is important. One means of increasing dosimetric accuracy is through the use of size-specific dosimetry, and the aim of this work was to de
Externí odkaz:
https://doaj.org/article/c953960a662748f2a33ab5df934a7648
Publikováno v:
Physica Medica. 99:10-15
BACKGROUND AND AIM: Dose management systems (DMS's) have been widely used for radiation dose data collection and analysis, and have been proven useful for optimization. Although DMS's are used for patient dosimetry, a quality assurance (QA) program h
Publikováno v:
Physica Medica. 104:S55-S56
Publikováno v:
Physica Medica. 104:S71-S72
Autor:
Niki Fitousi
Στα πλαίσια της διατριβής αυτής, αναπτύχθηκε ένα μοντέλο προσομοίωσης με βάση τις τεχνικές Monte Carlo για την υπολογιστική μελέτη της εφαρμ
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::dd6e2babd610c0a9d837b1db4ff72253
https://doi.org/10.12681/eadd/36307
https://doi.org/10.12681/eadd/36307
Publikováno v:
Physics in medicine and biology. 66(14)
Patient dose management systems can be part of a department's quality management tools to estimate items such as the radiation burden in specific groups or list dose outliers for further follow up. Patient size information could improve both aspects,
Autor:
Niki Fitousi
Publikováno v:
Physica Medica. 44:212-221
Purpose Due to the upcoming European Directive (2013/59/EURATOM) and the increased focus on patient safety in international guidelines and regulations, Patient Dose Monitoring Systems, also called Dose Management Systems (DMS), are introduced in medi
Publikováno v:
Physica Medica. 52:74-75
Purpose Estimate the patient size, in terms of water equivalent diameter (WED), for conventional abdominal anterior-posterior (AP) radiography by using parameters available in the DICOM-header. Methods The hypothesis of the present project was that t
Publikováno v:
Medical Physics. 39:2069-2077
Purpose: Synchrotron radiation (SR), being the brightest artificial source of x-rays with a very promising geometry, has raised the scientific expectations that it could be used for breast imaging with optimized results. The ''in situ'' evaluation of
Publikováno v:
Physica Medica. 52:102
Purpose Evaluate the effect of image truncation on the calculation of Water Equivalent Diameter (WED) for chest and abdomen Computed Tomography (CT) examinations. Correction factors for WED to rectify for the missing information were investigated. Me