Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Nicolas G R, Behl"'
Autor:
Daniel Paech, Sebastian Regnery, Tanja Platt, Nicolas G. R. Behl, Nina Weckesser, Paul Windisch, Katerina Deike-Hofmann, Wolfgang Wick, Martin Bendszus, Stefan Rieken, Laila König, Mark E. Ladd, Heinz-Peter Schlemmer, Jürgen Debus, Sebastian Adeberg
Publikováno v:
Frontiers in Neuroscience, Vol 15 (2021)
The purpose of this work was to prospectively investigate sodium (23Na) MRI at 7 Tesla (T) as predictor of therapy response and survival in patients with glioblastoma (GBM). Thus, 20 GBM patients underwent 23Na MRI at 7T before, immediately after and
Externí odkaz:
https://doaj.org/article/9d0825e26c4148e89c565dfc2960d5e2
Autor:
Matthias Utzschneider, Nicolas G. R. Behl, Sebastian Lachner, Lena V. Gast, Andreas Maier, Michael Uder, Armin M. Nagel
Publikováno v:
Magma (New York, N.Y.). 33(5)
The original version of this article unfortunately contained a mistake. Title was incorrect.
Autor:
Fabian J, Kratzer, Sebastian, Flassbeck, Armin M, Nagel, Nicolas G R, Behl, Benjamin R, Knowles, Peter, Bachert, Mark E, Ladd, Sebastian, Schmitter
Publikováno v:
Magnetic resonance in medicineREFERENCES. 84(5)
To evaluate the feasibility ofA framework for sodium relaxometry using MRF at 7T was developed, allowing simultaneous measurement of relaxation times and inhomogeneities in the static field. The technique distinguishes between bi- and monoexponential
Autor:
Johanna, Lott, Tanja, Platt, Sebastian C, Niesporek, Daniel, Paech, Nicolas, G R Behl, Thoralf, Niendorf, Peter, Bachert, Mark E, Ladd, Armin M, Nagel
Publikováno v:
Magnetic resonance in medicine. 82(1)
To quantify the tissue sodium concentration (TSC) in cardiacWithout any correction the measured myocardial TSC was (54 ± 5) mM. The applied correction methods reduced these values by (48 ± 5)% to (29 ± 3) mM, where PV correction had the largest ef
Autor:
Tanja, Platt, Reiner, Umathum, Thomas M, Fiedler, Armin M, Nagel, Andreas K, Bitz, Florian, Maier, Peter, Bachert, Mark E, Ladd, Mark O, Wielpütz, Hans-Ulrich, Kauczor, Nicolas G R, Behl
Publikováno v:
Magnetic resonance in medicine. 80(3)
Autor:
Jonathan M, Lommen, Sebastian, Flassbeck, Nicolas G R, Behl, Sebastian, Niesporek, Peter, Bachert, Mark E, Ladd, Armin M, Nagel
Publikováno v:
Magnetic resonance in medicine. 80(2)
To investigate and to reduce influences on the determination of the short and long apparent transverse relaxation times ( T2,s*, T2,l*) ofThe accuracy of T2* determination was analyzed in simulations for five different sampling schemes. The influence
Autor:
Sebastian C, Niesporek, Reiner, Umathum, Jonathan M, Lommen, Nicolas G R, Behl, Daniel, Paech, Peter, Bachert, Mark E, Ladd, Armin M, Nagel
Publikováno v:
Magnetic resonance in medicine. 79(6)
To assess the reproducibility ofDynamicComparison with the ground truth of simulations revealed improved CMROThis in vivo
Autor:
Kristian, Rink, Nadia, Benkhedah, Moritz C, Berger, Christine, Gnahm, Nicolas G R, Behl, Jonathan M, Lommen, Vanessa, Stahl, Peter, Bachert, Mark E, Ladd, Armin M, Nagel
Publikováno v:
Magnetic resonance imaging. 37
The purpose of this study is to improve direct phosphorus (
Publikováno v:
Magnetic resonance in medicine. 75(4)
To reduce noise and artifacts in (23)Na MRI with a Compressed Sensing reconstruction and a learned dictionary as sparsifying transform.A three-dimensional dictionary-learning compressed sensing reconstruction algorithm (3D-DLCS) for the reconstructio
Autor:
Olga, Bodet, Steffen, Goerke, Nicolas G R, Behl, Volkert, Roeloffs, Moritz, Zaiss, Peter, Bachert
Publikováno v:
NMR in biomedicine. 28(9)
Amide protons of peptide bonds induce an important chemical exchange saturation transfer (CEST) contrast in vivo. As a simple in vitro model for a peptide amide proton CEST effect, we suggest herein the dipeptide carnosine. We show that the metabolit