Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Nico Krauter"'
Autor:
Alexandru Onea, Nico Krauter, Wolfgang Hering, Stephan Lenk, Sebastian Ruck, Robert Stieglitz, Gunter Gerbeth
Publikováno v:
SolarPACES Conference Proceedings, Vol 1 (2024)
Liquid metals, such as sodium, have been already successfully used as heat transfer fluids (HTF) in concentrating solar power (CSP) plants up to ~550 °C. Even higher temperatures can be achieved and are envisioned for future CSP plants. The lack of
Externí odkaz:
https://doaj.org/article/4bb00c1cbccd4c16a6f6f9ee91b852a4
Autor:
Nico Krauter, Frank Stefani
Publikováno v:
Sensors, Vol 23, Iss 22, p 9018 (2023)
The Eddy Current Flow Meter (ECFM) is a commonly employed inductive sensor for assessing the local flow rate or flow velocity of liquid metals with temperatures up to 700 ∘C. One limitation of the ECFM lies in its dependency on the magnetic Reynold
Externí odkaz:
https://doaj.org/article/fc0db811d84b45fb987d2fdc12e82c2b
Autor:
Nico Krauter, Sven Eckert, Thomas Gundrum, Frank Stefani, Thomas Wondrak, Ruslan Khalilov, Ivan Dimov, Peter Frick
Publikováno v:
Sensors, Vol 20, Iss 23, p 6798 (2020)
In order to precisely determine the magnesium level in a titanium reduction retort by inductive methods, many interfering influences have to be considered. By using a look-up-table method, the magnesium level can be reliably identified by taking into
Externí odkaz:
https://doaj.org/article/0840b2431faa4ceaab687c129ff9ab32
Publikováno v:
Journal of Nuclear Engineering and Radiation Science. :1-34
We present measurement results for the flow rate of liquid sodium at temperatures up to 700°C that were obtained with a high temperature prototype of an immersed Eddy Current Flow Meter. The experimental campaign was conducted at the SOLTEC-2 sodium
Autor:
Nico, Krauter, Sven, Eckert, Thomas, Gundrum, Frank, Stefani, Thomas, Wondrak, Ruslan, Khalilov, Ivan, Dimov, Peter, Frick
Publikováno v:
Sensors 20(2020), 6798
Sensors, Vol 20, Iss 6798, p 6798 (2020)
Sensors
Volume 20
Issue 23
Sensors (Basel, Switzerland)
Sensors, Vol 20, Iss 6798, p 6798 (2020)
Sensors
Volume 20
Issue 23
Sensors (Basel, Switzerland)
In order to determine the magnesium level in a titanium reduction retort by inductive methods, many interfering influences have to be considered to achieve precise measurement results. By using a look-up-table method, the magnesium level can be ident
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=pmid_dedup__::9ce392205231c86f3cf150067e86fd90
https://www.hzdr.de/publications/Publ-31503-1
https://www.hzdr.de/publications/Publ-31503-1
Autor:
Martin Seilmayer, Nico Krauter
Publikováno v:
IEEE Sensors Journal. 18:1256-1264
A quasi-coaxial system consisting of a central current carrying copper rod and five symmetric return paths takes up to 20 kA. The installation provides a homogeneous magnetic field $\mathbf {B_{\varphi }}$ to a Taylor–Couette flow. One challenging
Publikováno v:
9th International Symposium on Electromagnetic Processing of Materials (EPM2018), 17.-18.10.2018, Awaji City, Japan
IOP Conference Series: Materials Science and Engineering 424(2018), 012078
IOP Conference Series: Materials Science and Engineering 424(2018), 012078
The inductive measurement of the magnesium level in a titanium reduction reactor is a challenging task because the state of the art measurement techniques are hampered by the formation of titanium sponge rings within the reactor. By distorting the ma
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4a262e69caa9b217b92cc6c2e1be2bfc
https://www.hzdr.de/publications/Publ-27751-2
https://www.hzdr.de/publications/Publ-27751-2
Autor:
Nico Krauter, Andrei Teimurazov, Thomas Gundrum, Peter Frick, Ruslan Khalilov, Thomas Wondrak, Sven Eckert, Frank Stefani
Publikováno v:
Metallurgical and Materials Transactions B 49(2018)4, 2089-2096
The determination of the Magnesium level in a Titanium reduction retort by inductive methods is often hampered by the formation of Titanium sponge rings which disturb the propagation of electromagnetic signals between excitation and receiver coils. W
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ecc37106cdb2bb2819fd0e2ddaeab596
https://www.hzdr.de/publications/Publ-27532-1
https://www.hzdr.de/publications/Publ-27532-1
Autor:
Nico Krauter, Frank Stefani
Publikováno v:
Measurement Science and Technology 28(2017), 105301
3rd Russian Conference on Magnetohydrodynamics, 18.-21.06.2018, Perm, Russland
3rd Russian Conference on Magnetohydrodynamics, 18.-21.06.2018, Perm, Russland
Eddy current flow meters (ECFM) are widely used for measuring the flow velocity of electrically conducting fluids. Since the flow induced perturbations of a magnetic field depend both on the geometry and the conductivity of the fluid, extensive calib
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d7c8f10b1ee88531c7e09f39af61463c
https://www.hzdr.de/publications/Publ-25714-1
https://www.hzdr.de/publications/Publ-25714-1