Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Nickolaj Feldt Jensen"'
Publikováno v:
Journal of Fungi, Vol 10, Iss 2, p 108 (2024)
The number of buildings experiencing humidity problems and fungal growth appears to be increasing as energy-saving measures and changes in construction practices and climate become more common. Determining the cause of the problem and documenting the
Externí odkaz:
https://doaj.org/article/58e005fc7c11482397def36c382f0cdb
Autor:
Ruut Hannele Peuhkuri, Søren Peter Bjarløv, Nickolaj Feldt Jensen, Casper Fabian Hillestrøm Pold, Morten Hjorslev Hansen, Christopher Just Johnston
Publikováno v:
Jensen, N F, Bjarløv, S P, Johnston, C J, Pold, C F H, Hansen, M H & Peuhkuri, R H 2020, ' Hygrothermal assessment of north-facing, cold attic spaces under the eaves with varying structural roof scenarios ', Journal of Building Physics, vol. 44, no. 1, pp. 33-36 . https://doi.org/10.1177/1744259119891753
Jensen, N F, Bjarløv, S P, Johnston, C J, Pold, C F H, Hjorslev Hansen, M & Peuhkuri, R H 2020, ' Hygrothermal assessment of north-facing, cold attic spaces under the eaves with varying structural roof scenarios ', Journal of Building Physics, vol. 44, no. 1, pp. 3-36 . https://doi.org/10.1177/1744259119891753
Jensen, N F, Bjarløv, S P, Johnston, C J, Pold, C F H, Hjorslev Hansen, M & Peuhkuri, R H 2020, ' Hygrothermal assessment of north-facing, cold attic spaces under the eaves with varying structural roof scenarios ', Journal of Building Physics, vol. 44, no. 1, pp. 3-36 . https://doi.org/10.1177/1744259119891753
The objective of this study was to test whether compliance with the current Danish best practice recommendations concerning design of the cold attic space will prevent damaging moisture levels. The project was performed as a full-scale experimental s
Publikováno v:
Jensen, N F, Bjarløv, S P, Rode, C, Andersen, B & Møller, E B 2021, ' Hygrothermal performance of six insulation systems for internal retrofitting solid masonry walls ', Journal of Building Physics, vol. 44, no. 6, pp. 539-573 . https://doi.org/10.1177/1744259120988745
The study investigated the hygrothermal performance and risk of fungal growth in a phenolic foam system with a closed cell structure and a diffusion-open and capillary active lime-cork based insulating plaster, for internal retrofitting purposes. The
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::88ea8a38f25f45e25187ce735fd9bdaa
https://vbn.aau.dk/da/publications/32d16bf8-bf02-41dc-a5ff-7f1efbd7cf49
https://vbn.aau.dk/da/publications/32d16bf8-bf02-41dc-a5ff-7f1efbd7cf49
Publikováno v:
Jensen, N F, Bjarløv, S P, Rode, C, Andersen, B & Møller, E B 2021, ' Laboratory-based investigation of the materials’ water activity and pH relative to fungal growth in internally insulated solid masonry walls ', Indoor Air, vol. 31, no. 4, pp. 1252–1266 . https://doi.org/10.1111/ina.12796
This project investigated fungal growth conditions in artificially contaminated interfaces between solid masonry and adhesive mortar for internal insulation. The project comprised several laboratory experiments: test of three fungal decontamination m
Publikováno v:
E3S Web of Conferences, Vol 172, p 01001 (2020)
Rode, C, Friis, N K, Pedersen, C & Jensen, N F 2020, ' Moisture performance of a new thermal insulation composite for interior application ', E3S Web of Conferences, vol. 172, 01001 . https://doi.org/10.1051/e3sconf/202017201001
Rode, C, Friis, N K, Pedersen, C & Jensen, N F 2020, ' Moisture performance of a new thermal insulation composite for interior application ', E3S Web of Conferences, vol. 172, 01001 . https://doi.org/10.1051/e3sconf/202017201001
The paper introduces prototypes of a new composite insulation product for interior application. The product consists of a standard mineral fibre insulation batt, which is wrapped in a combination of a thin fabric of moisture absorbing, capillary acti
Publikováno v:
E3S Web of Conferences, Vol 172, p 01003 (2020)
The study investigated the hygrothermal performance and risk of mould growth in two thermal insulation systems for internal retrofitting purposes; a phenolic foam system with a closed cell structure, and a capillary active diffusion-open lime-cork ba
Publikováno v:
ce/papers. 2:79-87
Publikováno v:
Journal of Physics: Conference Series. 2069:012079
This study investigated the hygrothermal performance of five insulation systems for internal retrofitting purposes. Focus was on the hygrothermal performance near partition brick walls compared to the middle of the wall. The setup comprised two insul
Autor:
Nickolaj Feldt Jensen, Tommy Odgaard, Birgitte Andersen, Carsten Rode, Eva B. Møller, Søren Peter Bjarløv
Publikováno v:
Building and Environment. 182:107011
The present project investigated the hygrothermal performance and risk of mould growth in solid masonry walls fitted with three diffusion-open capillary active interior insulation systems installed in containers with a controlled indoor climate. The
Publikováno v:
Jensen, N F, Bjarløv, S P, Rode, C & Møller, E B 2020, ' Hygrothermal assessment of four insulation systems for interior retrofitting of solid masonry walls through calibrated numerical simulations ', Building and Environment, vol. 180, 107031 . https://doi.org/10.1016/j.buildenv.2020.107031
The present research project investigates the hygrothermal performance of four insulation systems for internal retrofitting solid masonry walls with embedded wooden wall plate and beam end. The study was carried out through numerical simulations cali