Zobrazeno 1 - 10
of 102
pro vyhledávání: '"Nicholas J, Linker"'
Autor:
Dewi E. Thomas, MD, MRCP, Nicholas M. Child, PhD, FRCP, W. Andrew Owens, MD, FRCS(CTh), Nicholas J. Linker, MD, FHRS, Simon A. James, MBChB, MRCP, Andrew J. Turley, MBChB, FRCP
Publikováno v:
HeartRhythm Case Reports, Vol 2, Iss 5, Pp 432-435 (2016)
Externí odkaz:
https://doaj.org/article/b2b4f19e65fe41899ddc91af88c0e0b7
Autor:
Samuel G. Urwin, Hannah Patrick, Helen Cole, Robert Henderson, Mark A de Belder, Andrew Sims, Nicholas J. Linker, Kim Keltie, Lee Berry, Iain Willits, Helen Powell
Publikováno v:
European Heart Journal. Quality of Care & Clinical Outcomes
Aims Non-valvular atrial fibrillation (AF) greatly increases the risk of ischaemic stroke. For people with contraindications to oral anticoagulation, left atrial appendage occlusion (LAAO) provides a non-pharmacological management alternative. The ai
A 60-year-old man presented to the pacing department for a routine device check 6 months following an implant of a primary prevention CRT-D. This was implanted for persisting severe LV systolic dysfunction due to aortic regurgitation, treated with a
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::fe8a1f3f2ce15b9115cf4a0f67e1ee06
https://doi.org/10.1093/med/9780192844170.003.0069
https://doi.org/10.1093/med/9780192844170.003.0069
A patient awaiting AVN ablation for rapidly conducted AF had a PM implanted.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::ceff596ee770fab13efd18c9c669983d
https://doi.org/10.1093/med/9780192844170.003.0014
https://doi.org/10.1093/med/9780192844170.003.0014
A patient with dilated cardiomyopathy and a CRT-D underwent lead revision due to fracture of the ICD lead. A new ICD lead was implanted.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::6bde895cfe0ac897ffafab8eee11d581
https://doi.org/10.1093/med/9780192844170.003.0040
https://doi.org/10.1093/med/9780192844170.003.0040
A patient with dilated cardiomyopathy and LBBB implanted with a CRT-D was seen at follow-up. The patient had no complaints. Percentage of VP was 98% (with LV pacing only).
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::92bfb6c3d00950cbf3c9f84439cb1ab6
https://doi.org/10.1093/med/9780192844170.003.0054
https://doi.org/10.1093/med/9780192844170.003.0054
A 32-year-old woman attends the device clinic following an episode of palpitations. She had a CRT defibrillator implanted 2 years previously due to dilated cardiomyopathy with severe LV systolic dysfunction, New York Heart Association class III. She
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::82cdecb7a74fca34436a5c6dcf5f4eb7
https://doi.org/10.1093/med/9780192844170.003.0030
https://doi.org/10.1093/med/9780192844170.003.0030
A patient with paroxysmal AVB was implanted with a PM with HBP.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::39bc5a3e95e37a249af46f8903029251
https://doi.org/10.1093/med/9780192844170.003.0020
https://doi.org/10.1093/med/9780192844170.003.0020
Autor:
Christopher Monkhouse, Ian Williams, Matthew G.D. Bates, Jonathan M. Behar, Amal Muthumala, Nicholas J. Linker, Carl Hayward, M Chapman, Andrew J. Turley, Anthony Chow, Andrew R. Thornley, Matthew J Dewhurst
Publikováno v:
JACC: Clinical Electrophysiology. 5:1028-1035
Objectives This study sought to assess immediate and short-term performance of the Medtronic Attain Stability Quadripolar 4798 lead (Medtronic, Dublin, Ireland). Background Cardiac resynchronization therapy (CRT) is an established treatment for appro
Autor:
Lee Berry, Nicholas J. Linker, Iain Willits, Hannah Patrick, Robert Henderson, Kim Keltie, Helen Powell, Samuel G. Urwin, Andrew Sims, Helen Cole, Julie Speller, Mark A de Belder
Publikováno v:
PLoS ONE, Vol 16, Iss 5, p e0251463 (2021)
PLoS ONE
PLoS ONE
Aims Percutaneous mitral valve leaflet repair is a treatment option for some people with severe mitral valve regurgitation for whom conventional mitral valve surgery is clinically inappropriate. This study aimed to determine the safety, efficacy, and