Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Niamh A Kilcawley"'
Autor:
Philip L Early, Niamh A Kilcawley, Niamh A McArdle, Marine Renou, Sinéad M Kearney, Rohit Mishra, Nikolay Dimov, Macdara T Glynn, Jens Ducrée, David J Kinahan
Publikováno v:
PLoS ONE, Vol 18, Iss 9, p e0291165 (2023)
Due to their capability for comprehensive sample-to-answer automation, the interest in centrifugal microfluidic systems has greatly increased in industry and academia over the last quarter century. The main applications of these "Lab-on-a-Disc" (LoaD
Externí odkaz:
https://doaj.org/article/af46e4c90a544751ad089a4c93c9ad0b
Autor:
David J Kinahan, Sinéad M Kearney, Niamh A Kilcawley, Philip L Early, Macdara T Glynn, Jens Ducrée
Publikováno v:
PLoS ONE, Vol 11, Iss 5, p e0155545 (2016)
Here we present retrieval of Peripheral Blood Mononuclear Cells by density-gradient medium based centrifugation for subsequent analysis of the leukocytes on an integrated microfluidic "Lab-on-a-Disc" cartridge. Isolation of white blood cells constitu
Externí odkaz:
https://doaj.org/article/b2f83862bfa5499fb7557b2e52fa5ee3
Autor:
David J. Kinahan, Robert Burger, Daryl Lawlor, Philip L. Early, Abhishek Vembadi, Niamh A. McArdle, Niamh A. Kilcawley, Macdara T. Glynn, Jens Ducrée
Publikováno v:
Biosensors and Bioelectronics: X, Vol 9, Iss , Pp 100085- (2021)
This paper presents two flow-control technologies for use on centrifugal Lab-on-a-Disc systems. The first, immiscible liquid valving, selectively blocks microfluidic channels using a high-density liquid fluorocarbon (FC-40). Used with a specific chan
Externí odkaz:
https://doaj.org/article/f13e5b8f99e149edad5df481a2a6e9b4
Autor:
Niamh A. Kilcawley, Toni C. Voebel, Philip L. Early, Niamh A. McArdle, Marine Renou, Jeanne Rio, Godefroi Saint-Martin, Macdara T. Glynn, Daniel Zontar, Christian Brecher, Jens Ducrée, David J. Kinahan
Publikováno v:
Processes; Volume 11; Issue 1; Pages: 128
Lab-on-a-Disc (LoaD) has great potential for applications in decentralised bioanalytical testing where speed and robustness are critical. Here, a disc-shaped microfluidic chip is rotated to pump liquid radially outwards; thus, all microfluidic struct
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::738b2541484d326902ff9d22980b6566
https://publica.fraunhofer.de/handle/publica/430781
https://publica.fraunhofer.de/handle/publica/430781
Autor:
Philip L. Early, Macdara Glynn, David J. Kinahan, Daryl Lawlor, Abhishek Vembadi, Niamh A. Kilcawley, Niamh A. McArdle, Jens Ducrée, Robert Burger
Publikováno v:
Kinahan, David J. ORCID: 0000-0003-1968-2016 , Burger, Robert, Lawlor, Daryl, Earlya, Philip L., Vembadi, Abhishek, McArdle, Niamh A. ORCID: 0000-0003-4025-6302 , Kilcawley, Niamh, Glynn, Macdara ORCID: 0000-0002-6347-4348 and Ducrée, Jens ORCID: 0000-0002-0366-1897 (2021) Centrifugally automated Solid-Phase Extraction of DNA by immiscible liquid valving and chemically powered centripetal pumping of peripherally stored reagents. Biosensors and Bioelectronics, 9 . ISSN 0956-5663
Biosensors and Bioelectronics: X, Vol 9, Iss, Pp 100085-(2021)
Niamh McArdle
Biosensors and Bioelectronics: X, Vol 9, Iss, Pp 100085-(2021)
Niamh McArdle
This paper presents two flow-control technologies for use on centrifugal Lab-on-a-Disc systems. The first, immiscible liquid valving, selectively blocks microfluidic channels using a high-density liquid fluorocarbon (FC- 40). Used with a specific cha
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5cf25799abc67a827079f3c71b26c4ee
http://doras.dcu.ie/27468/
http://doras.dcu.ie/27468/
Autor:
Dermot Diamond, Thomas Glennon, Philip L. Early, David J. Kinahan, Abhishek Vembadi, Niamh A. Kilcawley, Dermot Brabazon, Jens Ducrée, Eoghan MacNamara
Publikováno v:
Lab on a Chip. 16:3454-3459
We introduce a novel instrument controlled valving scheme for centrifugal platforms which is based upon xurography. In a first approach, which is akin to previously presented event-triggered flow control, the valves are composed of a pneumatic chambe
Autor:
David J. Kinahan, Niamh A. Kilcawley, Saraí M. Torres Delgado, Dario Mager, Fralett Suarez Sandoval, Jens Ducrée, Lourdes Albina Nirupa Julius
Publikováno v:
Lab on a Chip. 16:4002-4011
Typical Lab-on-a-Disc (LoaD) platforms cannot make a continuous measurement while the disc is spinning; this drawback means that the disc usually must be stopped and aligned with a sensor. This can result in measurement errors in time-dependent assay
Autor:
Jens Ducrée, Niamh A. Kilcawley, Celina M. Miyazaki, David J. Kinahan, Marystela Ferreira, Faith Mangwanya, Rohit Mishra
Publikováno v:
Biosensorsbioelectronics. 119
As a direct, label-free method, Surface Plasmon Resonance (SPR) detection significantly reduces the needs for liquid handling and reagent storage compared to common enzyme-linked immunosorbent assays (ELISAs), thus enabling comprehensive multiplexing
Autor:
Sinéad M. Kearney, Macdara Glynn, Niamh A. Kilcawley, Jens Ducrée, Philip L. Early, David J. Kinahan
Publikováno v:
PLoS ONE, Vol 11, Iss 5, p e0155545 (2016)
PLoS ONE
PLoS ONE
Here we present retrieval of Peripheral Blood Mononuclear Cells by density-gradient medium based centrifugation for subsequent analysis of the leukocytes on an integrated microfluidic “Lab-on-a-Disc” cartridge. Isolation of white blood cells cons
Autor:
Macdara Glynn, David J. Kinahan, Marine Renou, Jens Ducrée, Colette McDonagh, Dirk Kurzbuch, Éanna Bailey, Niamh A. Kilcawley
Publikováno v:
Micromachines
Micromachines; Volume 7; Issue 10; Pages: 175
Micromachines, Vol 7, Iss 10, p 175 (2016)
Micromachines; Volume 7; Issue 10; Pages: 175
Micromachines, Vol 7, Iss 10, p 175 (2016)
We report a new flow control method for centrifugal microfluidic systems; CO2 is released from on-board stored baking powder upon contact with an ancillary liquid. The elevated pressure generated drives the sample into a dead-end pneumatic chamber se