Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Neha J. Parikh"'
Autor:
Neha J. Parikh, Anirban Roy, Ronald L. Brazg, James Thrasher, Bruce W. Bode, Andrew S. Rhinehart, Robert H. Slover, Lintereur Louis J, David R. Liljenquist, Scott W. Lee, Xiaoxiao Chen, Mark P. Christiansen, John H. Shin, Dorothy I. Shulman, Rodica Pop-Busui, Athena Philis-Tsimikas, Margaret Liu, Robert A. Vigersky, Benyamin Grosman, Anders L. Carlson, Jennifer L. Sherr, Mark Kipnes, Satish K. Garg, Di Wu, Fen Peng, Kamalpreet K. Singh, Kevin B. Kaiserman
Publikováno v:
Diabetes. 69
Background: Automated insulin delivery systems improve glycemic control including time spent in, below and above range (TIR, TBR and TAR, respectively) in people with T1D. A next generation system, the MiniMedTM AHCL system, that offers a target set
Autor:
Weydt Patrick E, Robert A. Vigersky, Benyamin Grosman, Mark P. Christiansen, Robert H. Slover, Anirban Roy, Neha J. Parikh, Di Wu, Dorothy I. Shulman, Lintereur Louis J
Publikováno v:
Diabetes. 69
Carbohydrate counting is a significant source of burden for individuals using insulin to mitigate postprandial glucose excursion. To address this, a meal simplification (MS) algorithm was developed that allows one to choose a ready and user-specific
Autor:
Di Wu, Ronald L. Brazg, Neha J. Parikh, Lintereur Louis J, Nicole Schneider, Satish K. Garg, Benyamin Grosman, Robert A. Vigersky, Anirban Roy
Publikováno v:
Diabetes. 69
Background: MiniMed™ 670G system user-dependent settings influence glycemic outcomes in persons with type 1 diabetes. The ability of a mathematical model-based digital-twin program to personalize and automate user-dependent MiniMed™ 670G settings
Autor:
Jeppe Sturis, Natalie Kurtz, Magnus Ekelund, Gayane Voskanyan, Robert A. Vigersky, Benyamin Grosman, Ohad Cohen, Neha J. Parikh, Anirban Roy, Di Wu
Publikováno v:
Computer Methods and Programs in Biomedicine. 205:106087
Introduction Medtronic has developed a virtual patient simulator for modeling and predicting insulin therapy outcomes for people with type 1 diabetes (T1D). An enhanced simulator was created to estimate outcomes when using the MiniMedTM 670G system w
Autor:
Lintereur Louis J, Benyamin Grosman, Anirban Roy, Francine R. Kaufman, Natalie Kurtz, Di Wu, Neha J. Parikh
Publikováno v:
Diabetes. 68
Background: Forgetting a premeal bolus can lead to hyperglycemia in patients with type 1 diabetes (T1D). A prototype e-HCL system was designed to automatically deliver basal insulin and correction boluses based on sensor glucose (SG) values. The effe
Publikováno v:
Diabetes. 67
The Medtronic MiniMed™ 670G hybrid closed-loop system was designed to automatically adjust basal insulin delivery every 5 minutes based on sensor glucose (SG) values. Its safety and effectiveness have been recently investigated in a multi-center pi
Publikováno v:
Diabetes. 67
The Medtronic MiniMed™ 670G hybrid closed-loop (HCL) system was investigated in a multi-center pivotal trial conducted in 1T1D children aged 7-13 years. A 3-month at-home study phase with Auto Mode enabled followed the 2 week run-in phase in Manual
Autor:
Lintereur Louis J, Neha J. Parikh, Di Wu, Francine R. Kaufman, Diana Miller, Benyamin Grosman, Anirban Roy
Publikováno v:
Diabetes technologytherapeutics. 20(3)
Simulations using mathematical models are important for studying, developing, and improving therapies for people with type 1 diabetes.The Medtronic CareLinkA total of 2087 virtual patients were developed. The time percentage between 70 and 180 mg/dL
Autor:
Neha J. Parikh, Francine R. Kaufman, John J. Mastrototaro, Barry Keenan, Benyamin Grosman, Anirban Roy, Natalie Kurtz, Aloke Mehta, Gayane Voskanyan, Mikhail Loutseiko
Publikováno v:
Journal of Diabetes Science and Technology. 7:465-477
In insulin pump therapy, optimization of bolus and basal insulin dose settings is a challenge. We introduce a new algorithm that provides individualized basal rates and new carbohydrate ratio and correction factor recommendations. The algorithm utili