Zobrazeno 1 - 10
of 42
pro vyhledávání: '"Neelakantan Saikrishnan"'
Publikováno v:
Cardiovascular Engineering and Technology. 9:273-287
Experimental flow field characterization is a critical component of the assessment of the hemolytic and thrombogenic potential of heart valve substitutes, thus it is important to identify best practices for these experimental techniques. This paper p
Autor:
Michael Markl, Lucia Mirabella, Neelakantan Saikrishnan, Ajit P. Yoganathan, Elizabeth R. Coco, Daniel Mangiameli, Alex J. Barker
Publikováno v:
Annals of Biomedical Engineering. 43:1815-1827
Bicuspid aortic valve (BAV) is the most common congenital heart defect and can lead to severe complications. Many studies have been conducted to evaluate the potential of geometric and hemodynamic biomarkers to predict BAV-related aortopathy. This wo
Publikováno v:
Biomechanics and Modeling in Mechanobiology. 14:577-588
Congenital bicuspid aortic valves (BAVs) are associated with accelerated disease progression, such as leaflet calcification and ascending aorta dilatation. Although common underlying genetic factors have been implicated in accelerated disease in BAV
Publikováno v:
Circulation. 129:244-253
Aortic valve (AV) stenosis is one of the most common valvular diseases and is the third most common cardiovascular disease in developed countries. It occurs in ≈2.8% of patients ≥75 years of age and can occur because of degenerative calcification
Publikováno v:
Annals of Biomedical Engineering. 42:526-540
A number of clinical, in vitro and computational studies have shown the potential for thromboembolic complications in bileaflet mechanical heart valves (BMHV), primarily due to the complex and unsteady flows in the valve hinges. These studies have fo
Autor:
Neelakantan Saikrishnan, Karyn S. Kunzelman, Jean-Pierre Rabbah, Ajit Prithivaraj Yoganathan, Andrew W. Siefert
Publikováno v:
Computer Methods in Biomechanics and Biomedical Engineering. 18:618-627
Computational models for the heart’s mitral valve (MV) exhibit several uncertainties which may be reduced by further developing these models using ground-truth data sets. The present study generated a ground-truth data set by quantifying the effect
Autor:
Jean-Pierre Rabbah, Steven A. Touchton, Jorge Hernan Jimenez, Neelakantan Saikrishnan, Ajit P. Yoganathan, Andrew W. Siefert, Jeremy R. McGarvey, Robert C. Gorman, Satoshi Takebayashi, Joseph H. Gorman
Publikováno v:
Journal of Biomechanics. 46:2550-2553
Mitral annuloplasty has been a keystone to the success of mitral valve repair in functional mitral regurgitation. Understanding the complex interplay between annular-ring stresses and left ventricular function has significant implications for patient
Publikováno v:
Cardiovascular Engineering and Technology. 4:427-439
Transcatheter Aortic Valve Replacement (TAVR) is currently used for patients with aortic valve disease at high risk for surgical intervention. The Lotus™ Valve system (Boston Scientific) is a novel repositionable TAVR with bovine pericardial leafle
Autor:
David A. Icenogle, Andrew W. Siefert, Jean-Pierre Rabbah, Stamatios Lerakis, Jarek Rossignac, Neelakantan Saikrishnan, Ajit P. Yoganathan
Publikováno v:
Annals of Biomedical Engineering. 41:1258-1268
Patient-specific models of the heart's mitral valve (MV) exhibit potential for surgical planning. While advances in 3D echocardiography (3DE) have provided adequate resolution to extract MV leaflet geometry, no study has quantitatively assessed the a
Autor:
Jean-Pierre Rabbah, Neelakantan Saikrishnan, Ajit P. Yoganathan, Andrew W. Siefert, Erin M. Spinner
Publikováno v:
The Annals of Thoracic Surgery. 94:1446-1453
Background Percutaneous edge-to-edge mitral valve (MV) repair is a potential therapeutic option for patients presenting with mitral regurgitation, who may not be suitable for surgery. We characterized the edge-to-edge repair forces in a posterior lea