Zobrazeno 1 - 10
of 153
pro vyhledávání: '"Nathan A Ledeboer"'
Autor:
Matthew L Faron, Blake W Buchan, Josh Hyke, Neil Madisen, Jennifer L Lillie, Paul A Granato, Deborah A Wilson, Gary W Procop, Susan Novak-Weekley, Elizabeth Marlowe, Joven Cumpio, Christen Griego-Fullbright, Sandra Kindig, Karen Timm, Stephen Young, Nathan A Ledeboer
Publikováno v:
PLoS ONE, Vol 10, Iss 11, p e0141350 (2015)
The prompt and accurate identification of bacterial pathogens is fundamental to patient health and outcome. Recent advances in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) have revolutionized bacterial i
Externí odkaz:
https://doaj.org/article/f321e71be9af41149c9b9ca627ae8dfd
Autor:
Blake W Buchan, Christine C Ginocchio, Ryhana Manii, Robert Cavagnolo, Preeti Pancholi, Lettie Swyers, Richard B Thomson, Christopher Anderson, Karen Kaul, Nathan A Ledeboer
Publikováno v:
PLoS Medicine, Vol 10, Iss 7, p e1001478 (2013)
BACKGROUND: A multicenter study was conducted to evaluate the diagnostic accuracy (sensitivity and specificity) of the Verigene Gram-Positive Blood Culture Test (BC-GP) test to identify 12 Gram-positive bacterial gene targets and three genetic resist
Externí odkaz:
https://doaj.org/article/9fafebf570f2457fbe47a50cc30dad26
Autor:
Hollis R. O’Neal, Jr, MD, MSc, Roya Sheybani, PhD, David R. Janz, MD, MSc, Robert Scoggins, MD, PhD, Tonya Jagneaux, MD, James E. Walker, MD, PhD, Daniel J. Henning, MD, MPH, Elizabeth Rosenman, MD, Simon A. Mahler, MD, MS, Hariharan Regunath, MD, Christopher S. Sampson, MD, D. Clark Files, MD, Richard D. Fremont, MD, Michael J. Noto, MD, PhD, Erica E. Schneider, MD, Wesley R. Shealey, MD, Matthew S. Berlinger, MD, Thomas C. Carver, MD, Morgan K. Walker, MD, Nathan A. Ledeboer, PhD, Ajay M. Shah, PhD, Henry T.K. Tse, PhD, Dino DiCarlo, PhD, Todd W. Rice, MD, MSc, Christopher B. Thomas, MD
Publikováno v:
Critical Care Explorations, Vol 6, Iss 2, p e1026 (2024)
OBJECTIVES:. To assess the in vitro IntelliSep test, a microfluidic assay that quantifies the state of immune activation by evaluating the biophysical properties of leukocytes, as a rapid diagnostic for sepsis. DESIGN:. Prospective cohort study. SETT
Externí odkaz:
https://doaj.org/article/63538c9b3c63401cb6b64ae711591b01
Autor:
Christopher S. Hollenbeak, PhD, Daniel J. Henning, MD, MPH, Glenn K. Geeting, MD, Nathan A. Ledeboer, PhD, Imran A. Faruqi, MD, Christi G. Pierce, DSc, MSHA, MBA, Christopher B. Thomas, MD, Hollis R. O’Neal, Jr, MD, MS
Publikováno v:
Critical Care Explorations, Vol 5, Iss 7, p e0942 (2023)
OBJECTIVES:. Sepsis causes 270,000 deaths and costs $38 billion annually in the United States. Most cases of sepsis present in the emergency department (ED), where rapid diagnosis remains challenging. The IntelliSep Index (ISI) is a novel diagnostic
Externí odkaz:
https://doaj.org/article/5240e930099f498eb5899bad7b385d61
Autor:
Chadd K. Kraus, H. Bryant Nguyen, Ryan C. Jacobsen, Nathan A. Ledeboer, Larissa S. May, Hollis R. O'Neal Jr., Michael A. Puskarich, Todd W. Rice, Wesley H. Self, Richard E. Rothman
Publikováno v:
Journal of the American College of Emergency Physicians Open, Vol 4, Iss 3, Pp n/a-n/a (2023)
Abstract Objectives Recent research has helped define the complex pathways in sepsis, affording new opportunities for advancing diagnostics tests. Given significant advances in the field, a group of academic investigators from emergency medicine, int
Externí odkaz:
https://doaj.org/article/11d3d6d9ad1a49bea61795950db0b4ce
Publikováno v:
American Journal of Clinical Pathology. 157:781-788
Objectives Aerococcus spp are Gram-positive cocci increasingly recognized as uropathogens. The Clinical and Laboratory Standards Institute recently published specific breakpoints for Aerococcus spp (M45, third edition); however, the standardized meth
Publikováno v:
Expert Review of Molecular Diagnostics
article-version (VoR) Version of Record
article-version (VoR) Version of Record
Introduction This expert review outlines current and future point-of-care technologies for the diagnosis of the SARS-CoV-2 virus, which is responsible for causing coronavirus disease COVID-19 in the emergency department. COVID-19 first emerged in lat
Publikováno v:
Journal of Adolescent Health. 69:574-578
Purpose Clean catch urine samples may be an alternative specimen to test for chlamydia and gonorrhea infections. The aim of this study was to determine the sensitivity and specificity of clean urine for chlamydia and gonorrhea in women. Methods This
Autor:
L. Silvia Munoz-Price, Ann Valley, Allison Reeme, Mary Beth Graham, Nathan A. Ledeboer, Frida Rivera, Blake W. Buchan
Publikováno v:
Infection Control & Hospital Epidemiology. 43:454-460
Objectives:The primary aim of this study was to assess the epidemiology of carbapenem-resistant Acinetobacter baumannii (CRAB) for 9 months following a regional outbreak with this organism. We also aimed to determine the differential positivity rate
Publikováno v:
Infection Control and Hospital Epidemiology
Infection Control & Hospital Epidemiology
Infection Control & Hospital Epidemiology
The household setting has some of the highest coronavirus disease 2019 (COVID-19) secondary-attack rates. We compared the air contamination in hospital rooms versus households of COVID-19 patients. Inpatient air samples were only positive at 0.3 m fr