Zobrazeno 1 - 10
of 22
pro vyhledávání: '"Namhun Cho"'
Publikováno v:
Energies, Vol 13, Iss 17, p 4367 (2020)
Recently, the demand for electricity has been increasing worldwide. Thus, more attention has been paid to renewable energy. There are acceptable limits during the integration of renewable energy into distribution systems because there are many effect
Externí odkaz:
https://doaj.org/article/f96798e4a9894b5aaae42695a50c2610
Autor:
Saeid Gholami Farkoush, Tahir Khurshaid, Abdul Wadood, Chang-Hwan Kim, Kumail Hassan Kharal, Kyu-Ho Kim, Namhun Cho, Sang-Bong Rhee
Publikováno v:
Complexity, Vol 2018 (2018)
A large number of electromagnetic transient studies have been analyzed for finding the overvoltage behavior of power system. A grounding grid of power system is so important for reducing the effect of overvoltage phenomena during a short-circuit even
Externí odkaz:
https://doaj.org/article/38b21e2d4d894444bcffa9ba32b33908
Publikováno v:
Applied Energy. 341:121059
Publikováno v:
The transactions of The Korean Institute of Electrical Engineers. 70:1274-1281
Publikováno v:
Renewable and Sustainable Energy Reviews. 109:102-115
Recent increases in Distributed Generation (DG) into distribution system have led to changes in the conventional protection scheme because of the reverse fault current coming from the DG side. However, it is not yet clear whether the reverse fault cu
Autor:
Tahir Khurshaid, Abdul Wadood, Chang-Hwan Kim, Sang-Bong Rhee, Namhun Cho, Saeid Gholami Farkoush
Publikováno v:
Journal of Electrical Engineering & Technology. 14:55-68
The coordination of directional overcurrent relays (DOCR) plays a very important role for maintaining security and enhancing reliability in the electrical power system. This paper presents the coordination of directional overcurrent relay using the m
Publikováno v:
Sustainability; Volume 14; Issue 15; Pages: 9781
Distributed energy resources (DERs), recently introduced into distribution systems, are mainly inverter-based distributed generations (IBDGs), which have different short-circuit behaviors from conventional synchronous-based distributed generations (S
Publikováno v:
Sustainability, Vol 13, Iss 7335, p 7335 (2021)
Sustainability
Volume 13
Issue 13
Sustainability
Volume 13
Issue 13
In general, a temporary overvoltage (TOV) on the healthy phases occurs because of the neutral-shift phenomenon during a single line-to-ground (SLG) fault. The TOV can destroy the insulation of electric devices and cause damage to other equipment and
Autor:
Dong-Eok Kim, Namhun Cho
Publikováno v:
Journal of Electrical Engineering and Technology. 12:522-532
In this study, we propose a fault analysis method for a power distribution grid with PCSbased DERs. We first explain the characteristics of a PCS-based DER. According to the characteristics, the DER is considered as a current-controlled voltage sourc
Publikováno v:
2019 IEEE Power & Energy Society General Meeting (PESGM).
Directional protective devices are utilized for reliable protection coordination in distribution system with Distributed Generation (DG). However, directional decision algorithm of Korea Electric Power Corporation (KEPCO) has found a problem to detec