Autor:
Matthias Loebe, Keith A. Youker, Nadim Nasir, Andrea M. Cordero-Reyes, Carlos M. Orrego, Jose H. Flores-Arredondo, Guilherme H. Oliveira, Guillermo Torre-Amione
Publikováno v:
Congestive Heart Failure. 17:140-146
Congest Heart Fail. 2011;17:140–146. ©2011 Wiley Periodicals, Inc. Left ventricular assist devices (LVADs) induce reverse cardiac remodeling by reducing myocyte size and collagen deposition. On the other hand, cardiac resynchronization therapy (CR
Autor:
Charles Shoultz, Henri Marais, Ellis Lader, Dhiraj Narula, Cezar Staniloae, Sam Durr, Kevin Marzo, Robert Mendelson, Bilal Malik, Suneet Mittal, Samir Saba, T. Jared Bunch, Rajul Patel, Leng Jiang, Shujahat Shah, Daniel C. Lee, Roopinder K. Sandhu, Steven Hsu, W. Kevin Tsai, Walid Saliba, Preetham Jetty, Kevin H. Silver, Frank Gredler, Zakir Sahul, James Bengston, Mark Niebauer, Neal A. Chatterjee, David B. Delurgio, Daniel G. Anderson, Scott E. Mattson, Greg C. Flaker, Daniel S. Menees, Elizabeth S Kaufman, Susan Graham, Chris Geohas, John F. Heitner, Joel Reinoehl, Otto Costantini, Pedro Colon-Hernandez, Frank McGrew, Brent McLaurin, Arthur Riba, Andre Gauri, Sung Lee, Zayd Eldadah, Nancy R. Cook, William Bugni, Gerald M. Pohost, Matthew Koshy, David E. Haines, Peter Ott, Romel Figueredo, Shelley R. Hankins, Alan H. Kadish, Christopher K. Dyke, Syed M. Mohiuddin, Kathryn Rohr, David Huneycutt, David Kraus, Marcus Averbach, Lindsey L. White, Peter Hotvedt, John McKenzie, David Sandler, Ronald Blonder, Mahmoud Atieh, Norman Erenrich, Sei Iwai, Aziz Hany, Ned Claxton, Hal Skopicki, Steven Klein, Geariod O'Neill, Sorin Danciu, Julie Pester, Diego Sadler, Robert Phang, Jay Schmidt, Udho Thadani, Azhar Aslam, M. Vinayaga Moorthy, Harischandra Karunaratne, James Baker, Jeffrey J. Goldberger, Sean Whalen, Michael Radin, Raul Garcia-Rinaldi, Ronald D. Berger, Michelle Ratliff, Steven D. Owens, Miguel Valderrábano, Christine M. Elbert, Steven Greenberg, Enrique Flores, Pablo Saavedra, Vincent See, David S. Rosenbaum, Michael Fong, Gopi Krishna Panicker, Steven Tishler, Joon Ahn, Mehmet K. Aktas, John E.A. Griffin, Edward Mostel, Stephen Hustead, Charles B. Treasure, Thomas Oliver, Terrence Hack, Talal Baki, Alexander Altschuller, Sharan Mahal, Michael Langer, Benjamin Trichon, Nadim Nasir, Juan M. Aranda, Mohit Bhasin, Patrick Simpson, David Bello, Selcuk Adabag, Kodangudi Ramanathan, Glover Johnson, William Wickemeyer, Charles Gottlieb, Jamal Islam, John Herre, David Wolinsky, Kevin Cochran, Lee Arcement, Judith A. Mackall, Gervasio Lamas, Jeffrey Shanes, Terence Ross, Mirza Baig, Joseph McGarvey, Stephanie H. Dunlap, Robert Weiss, Victoria Bernstein, Terrence X. O'Brien, Mark Myers, Benjamin Cheong, David Serfas, Robert Spencer, William Whang, Charles Gornick, Hemal M. Nayak, Andi Schaecter, J. Thomas Svinarich, Muqtada Chaudhry, P. Kasi Ramanathan, John Kazmierski, John Sobolski, Robert W Biederman, Andrew Sumner, Eve Gillespie, Christine M. Albert, Matthew Nora, Claudio Schuger
Publikováno v:
JAMA Cardiology. 3:591
Importance The majority of sudden and/or arrhythmic deaths (SAD) in patients with coronary heart disease occur in those without severe systolic dysfunction, for whom strategies for sudden death prevention are lacking. Objective To provide contemporar
Autor:
Tapan G. Rami, Nadim Nasir
Publikováno v:
Methodist DeBakey Cardiovascular Journal. 3:19-23
In millennia past, descriptions of congestive heart failure (CHF) often included ancient remedies. The earliest Egyptian papyri translated in the last century reveal a remarkably sophisticated understanding of heart ailments being the prime culprit i
Publikováno v:
Journal of the American College of Cardiology. 30:769-773
Objectives. The objective of this study was to evaluate the feasibility, safety and efficacy of placing implantable cardioverter-defibrillators (ICDs) in the electrophysiology laboratory using conscious sedation with combined hypnotic agents and deep
Publikováno v:
The American Journal of Cardiology. 73:554-558
The ability of Holter monitoring to predict clinical events during amiodarone therapy was evaluated in 83 patients with coronary artery disease and inducible monomorphic ventricular tachycardia. Sixty-four patients (77%) had significant ventricular e
Publikováno v:
Methodist DeBakey cardiovascular journal. 7(2)
VII (2) 2011 | MDCVJ Preoperative Clinical Course A 70-year-old white man with hypertension, diabetes mellitus, and hyperlipidemia was admitted to our hospital for dizziness and documented runs of nonsustained ventricular tachycardia (Figure 1). Seru
Autor:
Carlos M, Orrego, Nadim, Nasir, Guilherme H, Oliveira, Jose H, Flores-Arredondo, Andrea M, Cordero-Reyes, Matthias, Loebe, Keith A, Youker, Guillermo, Torre-Amione
Publikováno v:
Congestive heart failure (Greenwich, Conn.). 17(3)
Left ventricular assist devices (LVADs) induce reverse cardiac remodeling by reducing myocyte size and collagen deposition. On the other hand, cardiac resynchronization therapy (CRT) induces reverse cardiac remodeling by improving electromechanical s
There exist no standardized methods for culturing cardiac rhythm management devices. To identify the most optimal culturing method, we compared various techniques that comprise vortex, sonication, and incubation or combinations thereof. Incubation al
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::478117f6bb885b569d372064f2c1c5ab
https://europepmc.org/articles/PMC2786629/
https://europepmc.org/articles/PMC2786629/
Publikováno v:
The American Journal of Cardiology. 79:820-822
The database of the registry for an implantable cardioverter defibrillator was analyzed to determine the efficacy and safety of antitachycardia pacing for the termination of ventricular tachycardia. In 22,339 episodes treated, termination occurred in
Autor:
Philip D. Henry, Nadim Nasir, Timothy K. Doyle, Antonio Pacifico, Peter J. Wells, Kevin R. Wheelan, Susan A. Johnson
Publikováno v:
Circulation. 95(4)
Background Implantable cardioverter-defibrillators (ICDs) with intravenous electrode systems and downsized generators can be implanted by use of operative techniques similar to those employed for the insertion of permanent pacemakers. However, the sa