Zobrazeno 1 - 10
of 14
pro vyhledávání: '"NAVINESSHANI PERMAL"'
Publikováno v:
Systems and Soft Computing, Vol 6, Iss , Pp 200083- (2024)
This paper presents a Takagi-Sugeno (T-S) fuzzy type 1–2 controller for load frequency control (LFC). Most of the fuzzy controllers implemented for LFC in the past have Mamdani inference. Mamdani inferences give a fuzzy set that is defuzzified to f
Externí odkaz:
https://doaj.org/article/cf06e733d3eb47f9b53da6faba7a6c83
Publikováno v:
IEEE Access, Vol 9, Pp 37497-37509 (2021)
It is important to ensure that a grounding system is designed with a low magnitude of earth resistance, so the protection system can divert the large fault current to earth effectively. The performances and protection level of a grounding system need
Externí odkaz:
https://doaj.org/article/fe1fcb92b73442a8a3be07687d0b7e5d
Publikováno v:
IEEE Access, Vol 8, Pp 142468-142482 (2020)
Substations are important parts of electric power systems, and they require well-designed grounding systems. A proper grounding system guarantees the safety of the personnel working in an environment surrounded by grounded equipment from possible ele
Externí odkaz:
https://doaj.org/article/0bcbc59b96c340168ccbf51a094f2cde
Autor:
Navinesshani Permal, Miszaina Osman, Azrul Mohd Ariffin, Navaamsini Boopalan, Mohd Zainal Abidin Ab Kadir
Publikováno v:
PLoS ONE, Vol 16, Iss 9, p e0256298 (2021)
Grounding systems are critical in safeguarding people and equipment from power system failures. A grounding system's principal goal is to offer the lowest impedance path for undesired fault current. Optimization of the grounding grid designs is impor
Externí odkaz:
https://doaj.org/article/9b0880c30fef43ca816c9d984cea8dca
Publikováno v:
Applied Sciences, Vol 11, Iss 16, p 7468 (2021)
Designing an effective grounding system for AC substations needs predetermination of ground resistance and ground potential distribution caused by fault current’s presence in the ground. Therefore, it is necessary to have a suitable grounding grid
Externí odkaz:
https://doaj.org/article/dd002a17a665487b9ccf193b5a85710c
Publikováno v:
Pertanika Journal of Science and Technology. 30:1789-1814
Typically, the impact of the structure of vertically layered soil on the grounding behavior is not considered while designing a substation grounding system. Therefore, it will result in poor grounding designs due to computed inaccurate grid safety va
Publikováno v:
2022 IEEE International Conference on Power Systems Technology (POWERCON).
Autor:
Azrul Mohd Ariffin, Miszaina Osman, Raghavendra Ramachandra, Mohd Zainal Abidin Ab Kadir, NAVINESSHANI PERMAL
Publikováno v:
IEEE Access, Vol 9, Pp 37497-37509 (2021)
It is important to ensure that a grounding system is designed with a low magnitude of earth resistance, so the protection system can divert the large fault current to earth effectively. The performances and protection level of a grounding system need
Publikováno v:
Applied Sciences, Vol 11, Iss 7468, p 7468 (2021)
Designing an effective grounding system for AC substations needs predetermination of ground resistance and ground potential distribution caused by fault current’s presence in the ground. Therefore, it is necessary to have a suitable grounding grid
Autor:
Navinesshani Permal, Agileswari K. Ramasamy, Renuga Verayiah, Farrukh Nagi, Sanuri Ishak, Thiviya Barathi Raja Segaran
Publikováno v:
ICCCS
Bird activities at the transmission line threatens the safety and stability of transmission lines which results in power disruption. Current available ultrasonic bird deterrent system is not effective in eliminating bird activity at transmission line