Zobrazeno 1 - 10
of 27
pro vyhledávání: '"N. N. Trifonov"'
Publikováno v:
Safety and Reliability of Power Industry. 13:290-295
In the thermal circuits of domestic steam turbines, mixing-type low-pressure heaters (LPH) with free-flow jet water distribution and counter-flow of water and steam are widely used. The choice of the counterflow variant of the media movement ensures
Autor:
Yu. G. Sukhorukov, T. G. Sintsova, F. A. Svyatkin, N. N. Trifonov, E. K. Nikolaenkova, S. B. Esin, V. S. Modestov
Publikováno v:
Thermal Engineering. 64:568-573
The structures of low-pressure heaters (LPH), which are installed at nuclear power plants with the K-1000-60/1500 type turbine plants are considered. It was revealed that only the PND-3 type low-pressure heaters have the damages of the heat exchange
Autor:
P. Yu. Prikhod’ko, A. Yu. Yurchenko, E. B. Nabagez, F. A. Svyatkin, S. B. Esin, Yu. G. Sukhorukov, E. K. Nikolaenkova, N. N. Trifonov, P. V. Egorov, V. V. Nazarov
Publikováno v:
Safety and Reliability of Power Industry. 10:249-256
Development of advanced high-power steam-turbine plants (STP) involves paying a particular attention to design of reliable and economical high-pressure heater (HPH) capable to maintain the specified thermal hydraulic performance throughout its servic
Autor:
K. A. Grigoryev, S. B. Esin, E. K. Nikolaenkova, F. A. Svyatkin, N. N. Trifonov, T. G. Sintsova, E. B. Nabagez, P. V. Egorov, Yu. G. Sukhorukov
Publikováno v:
Safety and Reliability of Power Industry. 10:340-347
In the Russian energy sector, the process of modernization of turbine units with a capacity of 100÷800 MW is underway aimed at increasing their capacity and improving the efficiency of the wheelspace of turbine units. The modernization focuses on th
Publikováno v:
International Journal of Energy for a Clean Environment. 18:39-59
Autor:
V. V. Nazarov, S. B. Esin, P. Yu. Prikhod’ko, E. B. Grigor’eva, F. A. Svyatkin, N. N. Trifonov, Yu. G. Sukhorukov, A. Yu. Yurchenko, E. K. Nikolaenkova
Publikováno v:
Thermal Engineering. 63:636-642
In the development of advanced high-power steam-turbine plants (STP), special attention is placed on the design of reliable and economical high-pressure heater (HPH) capable to maintain the specified thermal hydraulic performance during the entire se
Autor:
E. K. Nikolayenkova, S. B. Yesin, T. G. Sintsova, E. B. Grigorieva, F. A. Svyatkin, N. N. Trifonov, A. Yu. Yurchenko, M. G. Ukhanova
Publikováno v:
Thermal Engineering. 63:174-178
The regeneration system heaters are one of the sources of possible ingress of the water into the turbine. The water penetrates into the turbine either at the heaters overflow or with the return flow of steam generated when the water being in the heat
Autor:
A. V. Medvedkin, A. Yu. Yurchenko, S. B. Esin, V. A. Ryabich, N. N. Trifonov, D. A. Zhivykh, I. P. Snegin, E. B. Grigor’eva, Yu. G. Sukhorukov
Publikováno v:
Thermal Engineering. 62:621-624
More than 30 power units of thermal power stations, based on the nondeaerating heat balance diagram, successfully operate in the former Soviet Union. Most of them are power units with a power of 300 MW, equipped with HTGZ and LMZ turbines. They opera
Autor:
Yu. G. Sukhorukov, V. F. Ermolov, E. K. Nikolaenkova, F. A. Svyatkin, S. P. Bik, N. N. Trifonov, T. G. Sintsova, E. B. Grigor’eva, E. A. Golubev, V. B. Tren’kin, S. B. Esin, M. G. Ukhanova
Publikováno v:
Thermal Engineering. 61:425-432
The equipment of the Kalinin NPP Unit 4 regeneration, intermediate separation, and steam reheating (ISSR) systems is described and the results of their static and dynamic tests are presented. It was shown from an analysis of test results that the equ
Autor:
V. A. Koltunov, A. I. Borovkov, N. N. Trifonov, M. G. Ukhanova, F. A. Svyatkin, O. I. Klyavin, V. B. Tren’kin
Publikováno v:
Thermal Engineering. 60:635-642
Experience gained from operation of high-pressure heaters and their protection systems serving to exclude ingress of water into the turbine is analyzed. A formula for determining the time for which the high-pressure heater shell steam space is filled