Zobrazeno 1 - 10
of 36
pro vyhledávání: '"N. Coursol"'
Autor:
N. Coursol, A. Kovalík, E.A. Yakushev, V.M. Gorozhankin, V.V. Tsupko-Sitnikov, M.A. Mahmoud, A.F. Novgorodov
Publikováno v:
Journal of Electron Spectroscopy and Related Phenomena. 95:231-254
The electron spectrum from the atomic deexcitation of 131Xe following both the electron capture (EC) decay of 131Cs and the β− decay of 131I has been analyzed in the energy region from 100 eV up to 36 keV using a combined electrostatic spectromete
Autor:
A. Kovalík, M. Ryšavý, Ch. Briançon, Ts. Vylov, E.A. Yakushev, N. Coursol, V.M. Gorozhankin, O. Dragoun, D.V. Filosofov, A. Minkova
Publikováno v:
Journal of Electron Spectroscopy and Related Phenomena. 95:1-24
The low-energy electron spectrum from the 57Co decay has been examined in the region from 0 up to 15 keV at instrumental resolution ranging from 2 to 15 eV. Two electrostatic spectrometers and radioactive sources prepared by vacuum evaporation of 57C
Autor:
S. A. Karamian, D. Trubert, M. Hussonnois, Yu. Ts. Oganessian, J. Morel, N. Coursol, Ch. Briançon, O. Constantinescu, M. Etcheverry, J. B. Kim
Publikováno v:
Journal of Radioanalytical and Nuclear Chemistry. 215:229-233
Nowadays large interest is attached to the production of exotic beams and targets for nuclear structure and reaction studies. The nucleus178Hf, with is long-lived (T1/2=31 years) high-spin isomeric statelπ=16+ at a relatively low-excitation energy (
Autor:
J. W. Zhou, J. L. Picolo, J. Bouchard, J.-P. Torre, N. Coron, D. Massé, N. Coursol, Jacques Leblanc, P. de Marcillac, H. Henry Stroke
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 339:131-136
Thermal cryogenic detectors (bolometers, microcalorimeters) have been operated in the pulse mode to quantify ionizing radiation. These detectors exhibit considerable promise for applications in high resolution spectrometry and integral counting. A co
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 339:343-348
An international intercomparison of internal proportional gas counting of 85 Kr and 3 H has been carried out under the auspices of EUROMET, a European Collaboration in Measurement Standards. A sample of 85 Kr mixed with inactive krypton gas was measu
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 339:146-150
Non-neutron nuclear data (half-lives, transition intensities, radiation energies and emission probabilities) have been re-evaluated for the radionuclides that constitute the decay chain of uranium-238 on the basis of new absolute measurements underta
Autor:
J. Bouchard, D. Massé, G. Dambier, P. de Marcillac, G. E. Artzner, J. W. Zhou, G. Nollez, G. Jegoudez, N. Coron, J. L. Picolo, H. Henry Stroke, C. Golbach, J. P. Lepeltier, N. Coursol, Jacques Leblanc
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 312:24-33
Two major limitations met in the field of ionizing radiation metrology, i.e. energy resolution and detection energy threshold, may be improved by one or two orders of magnitude by using composite bolometers cooled below 300 mK and operating in the pu
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 286:589-594
Non-neutron nuclear data (half-lives, transition intensities, radiation energies and emission probabilities) have been evaluated for the radionuclides constituting the decay chain of uranium-238. A selection of the many recommended data are presented
Publikováno v:
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 56(1-2)
In internal gas proportional counting, the evaluation of counting losses is important in order to obtain high accuracy measurement results. In this paper, counting losses due to the wall effect not counted and beta particles with very low energy are
Publikováno v:
Applied Radiation and Isotopes
Conference on Radionuclide Metrology and its Applications ICRM'2001
Conference on Radionuclide Metrology and its Applications ICRM'2001, May 2001, Braunschweig, Germany. pp.189-197
Conference on Radionuclide Metrology and its Applications ICRM'2001
Conference on Radionuclide Metrology and its Applications ICRM'2001, May 2001, Braunschweig, Germany. pp.189-197
The IC(4) software developed to compare calculated internal conversion coefficients (ICC) has been enhanced by adding new features through the use of Borland Delphi and TeeChart. Particularly, the 3D-graph option enhances the possibilities of analyzi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e709ce21d02d4fe74166179c918c2792
http://hal.in2p3.fr/in2p3-00011407
http://hal.in2p3.fr/in2p3-00011407