Zobrazeno 1 - 10
of 122
pro vyhledávání: '"N. Berme"'
Autor:
M. Gorriño Angulo, F. Sádaba Garay, L. Oleaga Zufiria, O. Gorriño Angulo, J.J. Gómez Muga, N. Bermejo Espinosa
Publikováno v:
Neurología (English Edition), Vol 25, Iss 5, Pp 287-294 (2010)
Background and purpose: The purpose of this article is to assess the validity of the magnetic resonance imaging (MRI) CISS 3D sequence associated with 3D time of flight (TOF) angiographic sequence in order to detect neurovascular contact (NVC) betwee
Externí odkaz:
https://doaj.org/article/f11c62116d384d6bbe8e34f526c5ce6f
Autor:
N. Berme
The widespread occurrence of the various forms of arthritis not only results in a great waste of manpower, but also causes immeasurable pain and suffering for the patients. Due to the limited understanding of its etiology, the currently available tre
Publikováno v:
Biomedical sciences instrumentation. 37
Designing a strain gage based force transducer is considered more of an art than an engineering process. Only general guidelines are available, and many trial and error iterations are needed to optimize the geometry and minimize the errors caused by
Publikováno v:
Biomedical sciences instrumentation. 35
Acquiring valid data is one of the major difficulties in gait analysis. Our previous study proved that, using the currently commercially available force plates, there is a low probability that every trial will be successful, and some subjects will ha
Publikováno v:
Biomedical sciences instrumentation. 35
Ballistocardiography is a non-invasive technique for the assessment of the cardiac function. It consists in studying the resultant forces generated by the blood mass flowing in the cardio-circulatory system while the subject lies on an instrumented b
Publikováno v:
Biomedical sciences instrumentation. 36
A system for the measurement of forces in noninertial reference systems, and a possible solution to compensate force plate readings by means of accelerometers were investigated. If the force plate can be considered a rigid body, six linear accelerome
Publikováno v:
Biomedical sciences instrumentation. 34
The ability to capture analog signals in a digital format suitable for subsequent storage, processing and analysis by a computer has revolutionized many scientific fields, including biomechanics. In the process of going from the analog signal to its
Publikováno v:
Biomedical sciences instrumentation. 34
A major difficulty in using force plates for gait analysis is to have a foot fall completely on the instrument while not having the other foot in contact with the same device. This translates into more trials (and time) required to obtain valid data.
Publikováno v:
Biomedical sciences instrumentation. 33
Simulation is becoming an increasingly accepted method for training personnel for complex or high risk tasks. With the advent of modern Virtual Reality (VR) technology, such simulations are becoming more and more immersive. One significant limitation
Publikováno v:
Biomedical sciences instrumentation. 33
In an effort to investigate the mechanics of drop landing on a flat surface, bilateral performance characteristics during the landing were investigated. Two force plates were used as landing surfaces, and the six component kinetic time histories and