Zobrazeno 1 - 7
of 7
pro vyhledávání: '"N J, Hallab"'
Publikováno v:
Molecular and cellular biochemistry. 222(1-2)
Metal toxicity from sources such as orthopaedic implants was investigated in terms of immune system hyper-reactivity to metal implant alloy degradation products. Lymphocyte response to serum protein complexed with metal from implant alloy degradation
Publikováno v:
Journal of biomedical materials research. 56(3)
The lymphocyte response to serum protein complexed with metal from implant alloy degradation was investigated in this in vitro study using primary human lymphocytes from healthy volunteers (n = 10). Cobalt chromium molybdenum alloy (Co-Cr-Mo, ASTM F-
Publikováno v:
Journal of biomedical materials research. 53(5)
The determination of biocompatibility has been dominated historically by the characterization of candidate materials based upon the observation of adverse host responses. However, some adverse responses are subtle in clinical settings and continue to
Publikováno v:
Journal of biomedical materials research. 49(3)
The distribution of titanium [Ti] and chromium [Cr] in serum protein fractions of patients with and without total joint replacements containing Cr and Ti was studied. Three groups were evaluated: 10 patients with cobalt-chromium [CoCr] alloy prosthes
Publikováno v:
Clinical orthopaedics and related research. (358)
Concentrations of titanium, aluminum, and vanadium were measured in the serum and urine of patients with titanium alloy cementless primary total knee arthroplasty components. Patients were categorized in one of five groups. In Group 1, the patellar a
Publikováno v:
Journal of long-term effects of medical implants. 5(3)
Adhesion of cells to a biomaterial surface can be a major factor mediating its biocompatibility. In this investigation, jet impingement techniques were used to quantify strength of cellular adhesion to various material surfaces. The metals tested: HS
Autor:
Samelko L; L. Samelko, K. McAllister, J. J. Jacobs, Rush University Medical Center, Chicago, IL, USA., Petfield J; J. Petfield, M. Hawkinson, San Antonio Medical Center, San Antonio, TX, USA., McAllister K; L. Samelko, K. McAllister, J. J. Jacobs, Rush University Medical Center, Chicago, IL, USA., Hsu J; J. Hsu, Carolinas Medical Center, Charlotte, NC, USA., Hawkinson M; J. Petfield, M. Hawkinson, San Antonio Medical Center, San Antonio, TX, USA., Jacobs JJ; L. Samelko, K. McAllister, J. J. Jacobs, Rush University Medical Center, Chicago, IL, USA., Hallab NJ; N. J. Hallab, Rush University Medical Center, Chicago, IL, USA.
Publikováno v:
Clinical orthopaedics and related research [Clin Orthop Relat Res] 2020 Apr; Vol. 478 (4), pp. 752-766.