Zobrazeno 1 - 3
of 3
pro vyhledávání: '"Mostafa Eshaghi Milasi"'
Publikováno v:
IEEE Transactions on Industrial Electronics. 68:7485-7495
An invasive diagnostic technique is proposed in this article for the detection and discrimination of turn-to-turn faults in the stator and rotor windings of synchronous machines during the startup period. For this purpose, search coils are installed
Publikováno v:
IEEE Transactions on Energy Conversion. 36:264-271
A portable flux probe is proposed and investigated in this article to detect turn-to-turn fault in the rotor poles of the high rated salient pole synchronous machines. The rotor circuit is fed by a low amplitude sinusoidal voltage source with a fixed
Publikováno v:
IEEE Transactions on Energy Conversion. 35:292-301
A flux-based technique is proposed for the on-line detection, localization and discrimination of stator and rotor turn-to-turn faults in synchronous generators, using the measured air-gap rotational magnetic field. Simple magnetic field sensors (MFSs