Zobrazeno 1 - 10
of 29
pro vyhledávání: '"Monique Donkerwolcke"'
Autor:
Maryse Etienne-Julan, M Mukisi-Mukaza, C. Saint-Martin, Franz Léon Burny, M.E. Burny, Monique Donkerwolcke
Publikováno v:
Revue de Chirurgie Orthopédique et Traumatologique. 97:801-807
Resume Introduction La drepanocytose est un probleme de sante publique pour lequel l’OMS recommande une prise en charge globale afin de reduire la mortalite et la morbidite. En l’absence de schema de prise en charge des complications osteo-articu
Publikováno v:
Orthopedics. 7(12)
The external fixator provides a mechanical connection between the bone fragments and recording devices or power systems. We have used this characteristic of external fixation since 1965 to record deformations occurring at the fracture site and to mea
Autor:
Monique Donkerwolcke, Michael Catrysse, Robert Puers, E Louridas, F Moulart, Glenn Vandevoorde, Franz Léon Burny, Richard Collier
Publikováno v:
Sensors and Actuators A: Physical. 85:42-47
This paper proposes a system for the detection of hip prosthesis loosening by means of a vibration analysis technique. Although this technique has been adapted before, the novelty presented here lies in the fact that the monitoring is done inside the
Publikováno v:
Biomaterials. 19:1461-1466
Glues and adhesives attach to a surface principally involving molecular attraction, whereas cements mostly work through mechanical interlocking. The adhesive and its degradation products must be biocompatible: chemical, clinical, legal, physical aspe
Publikováno v:
Materials Science and Engineering: A. 199:53-59
To treat diseases or disabilities, medicine and surgery use drugs and/or biomaterials. Devices used in the biomedical sector are often classified as a single sector (biomedical devices) which in reality comprises different market niches requiring app
We designed a sensor that measures the bending moments at the articulations and the torque of the rod of a Hoffmann II® external fixation. We considered the effect of the callus formation in the stabilisation of a "fracture-fixation system."Four Hof
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7bc09aa0052eb0f740a1217b4743afe8
https://europepmc.org/articles/PMC3508033/
https://europepmc.org/articles/PMC3508033/
Publikováno v:
Clinical Materials. 17:17-21
One of the factors determining the stability of osteosynthesis is the mechanical strength of the bone fragments required for the anchorage of the implant. The aim is to study the driving of a Thornton nail in the proximal epiphysis of a human femur a
Autor:
Maurice Hinsenkamp, Monique Donkerwolcke, Anne Gomez-Brouchet, M Mukisi-Mukaza, Franz Léon Burny
Publikováno v:
International orthopaedics. 35(8)
This study compares the histopathology of bone biopsies from patients suffering from sickle cell anaemia (homozygote SS) to heterozygote patients (SA) and homozygotes with aseptic osteonecrosis (AA). The sensitivity to bacterial infection of sickle c
Publikováno v:
Orthopaedicstraumatology, surgeryresearch : OTSR. 95(7)
SummaryIntroductionThe young age of patients, total arthroplasties complications risks, and implant costs justify evaluation of the results of core decompression in the treatment of sickle-cell disease avascular necrosis of the femoral head (ONFH).Hy
Autor:
Monique Donkerwolcke, F Rodes, F Moulart, Robert Puers, J-B. Begueret, K. Van Schuylenbergh, Franz Léon Burny, Mário A. Barbosa, P Lawes, O. C. Paiva, R Bourgois
Publikováno v:
Medical engineeringphysics. 22(7)
Extensive clinical experience has been built up using orthopaedic implants instrumented with strain gauges connected to a Wheatstone bridge by means of percutaneous leads. This research showed the medical relevance of the monitoring of the deformatio