Zobrazeno 1 - 10
of 30
pro vyhledávání: '"Mital H, Dave"'
Publikováno v:
Pediatric Anesthesia. 31:695-701
BACKGROUND In clinical practice, the cuff inflation line of cuffed pediatric tracheal tubes often interferes with securing tracheal tubes. METHODS The insertion site of the cuff inflation lines and the lengths of four different brands and nine sizes
Publikováno v:
Pediatric Anesthesia. 31:474-481
BACKGROUND Balloon-tipped bronchial blocker catheters are widely used in pediatric thoracic anesthesia to establish single-lung ventilation. In clinical practice, their balloons demonstrate sudden expansion when inflated with air. In addition, there
Autor:
Berthold Moser, Alexander Dullenkopf, Michael Kemper, Philipp K. Buehler, Mital H. Dave, Markus Weiss
Publikováno v:
Pediatric Anesthesia. 31:167-177
Background: Cuffed tracheal tubes have recently been recommended for selective endobronchial intubation to establish single-lung ventilation even in smaller children. This implies that, compared with uncuffed tracheal tubes, the cuffed tracheal tubes
Publikováno v:
Paediatric anaesthesiaREFERENCES. 31(11)
Background Appropriate size selection of pediatric rigid bronchoscopes is fundamental to avoidance of airway trauma and to a high success rate with the first intubation attempt. The aim of the present study was to compare the outer diameters of pedia
Autor:
Maren Kleine-Brueggeney, Michael Kemper, Mital H. Dave, Markus Weiss, Georg Henze, Markus Goetschi
Publikováno v:
Paediatric anaesthesiaREFERENCES. 30(11)
Background Age-related recommendations for size selection of bronchial blocker devices are based on a few dated anatomical autopsy and radiological studies determining lower airway dimensions in children. These recommendations are based on anterior-p
Publikováno v:
Acta Anaesthesiologica Scandinavica. 63:187-194
Introduction Airway management in severely obese patients remains a challenging issue for anaesthetists and may lead to life-threatening situations. Supraglottic airway devices, such as the i-gel™ or the AuraGain™, were developed, with the possib
Publikováno v:
Pediatric Anesthesia. 27:1043-1049
SummaryBackground The aim of this study was to obtain lower airway dimensions in children by means of computed tomography (CT). Methods Chest CT scans from 195 pediatric patients (118 boys/77 girls) aged 0.04-15.99 years were analyzed. Tracheal and b
Publikováno v:
Paediatric anaesthesiaREFERENCES. 30(4)
BACKGROUND Reliable sealing of the pediatric airway requires appropriately sized tracheal tube cuffs. The aim of this study was to compare residual cuff diameters of pediatric tracheal tubes with pediatric airway dimensions. METHODS Cuff diameters of
Publikováno v:
Paediatric anaesthesiaREFERENCES. 29(8)
Background Age-related pediatric airway dimension reference values for cricoid, tracheal, and bronchial diameters as well as tracheal and bronchial lengths are essential for distinguishing normal from pathological airway findings and for manufacturin
Background Tracheal tube tip and cuff positions of different cuffed paediatric tracheal tube brands in the trachea can vary with design. Methods Data from three clinical studies with measured tracheal lengths were pooled in a database including 422 c
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::82c09c12dc4f7b901311321d7f9075f2
https://www.zora.uzh.ch/id/eprint/160100/
https://www.zora.uzh.ch/id/eprint/160100/