Zobrazeno 1 - 10
of 101
pro vyhledávání: '"MiniArc"'
Publikováno v:
Gynecology and Minimally Invasive Therapy, Vol 10, Iss 4, Pp 235-242 (2021)
Objective: To compare the clinical efficacy and urodynamic parameter changes between the MiniArc and the Solyx sling for the treatment of female urodynamic stress incontinence (USI).Materials and Methods: One-hundred and thirty (MiniArc n = 79, BS-So
Externí odkaz:
https://doaj.org/article/5bc264fe065c4dc5934270c5ff20588d
Autor:
Miriam Campos-Delgado, Cecilia Quetglas-Muñoz, Marc Barahona-Orpinell, Amparo García-Tejedor, Jordi Ponce-Sebastià
Publikováno v:
Gynecology and Minimally Invasive Therapy, Vol 8, Iss 3, Pp 113-117 (2019)
Aims: The aim of the study is to assess the feasibility of ambulatory stress urinary incontinence (SUI) surgery using the MiniArc Precise single-incision urethral sling without increasing the number of complications. Settings and Design: This was a r
Externí odkaz:
https://doaj.org/article/563a76fa3f2840e0ac06985f8ec20de4
Publikováno v:
BMC Urology, Vol 18, Iss 1, Pp 1-10 (2018)
Abstract Background Adjustable single-incision mini-sling (SIMS) is a new category of SIMS for stress urinary incontinence (SUI). The aim of this study was to compare the efficacy and safety of adjustable single-incision mini-sling with other slings.
Externí odkaz:
https://doaj.org/article/39720bbdceb0454db2cb0c52cffc48fb
Publikováno v:
Taiwanese Journal of Obstetrics & Gynecology, Vol 55, Iss 4, Pp 519-524 (2016)
Objective: Voiding dysfunction following a midurethral sling procedure is still a relevant consequence that can affect patients' quality of life. Various invasive methods have been described to manage this problem. We hypothesize that we if we could
Externí odkaz:
https://doaj.org/article/59e8a55fec8d4808b56e3cdd80c14ed8
Publikováno v:
Taiwanese Journal of Obstetrics & Gynecology, Vol 55, Iss 1, Pp 20-25 (2016)
Objective: To ascertain whether low preoperational maximal urethral closure pressure (MUCP) affects the outcomes of single incision sling (SIS) procedures and changes MUCP values postsurgery. Material and methods: There were 112 (MUCP ≥ 40 cmH2O, n
Externí odkaz:
https://doaj.org/article/ce195fdf8b33461d991969cb0cb02c58
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Amparo Garcia-Tejedor, Marc Barahona-Orpinell, Jordi Ponce-Sebastià, Cecilia Quetglas-Muñoz, Miriam Campos-Delgado
Publikováno v:
Gynecology and Minimally Invasive Therapy
Gynecology and Minimally Invasive Therapy, Vol 8, Iss 3, Pp 113-117 (2019)
Gynecology and Minimally Invasive Therapy, Vol 8, Iss 3, Pp 113-117 (2019)
Aims: The aim of the study is to assess the feasibility of ambulatory stress urinary incontinence (SUI) surgery using the MiniArc Precise single-incision urethral sling without increasing the number of complications. Settings and Design: This was a r
Publikováno v:
Gynecology and Minimally Invasive Therapy
Gynecology and Minimally Invasive Therapy, Vol 10, Iss 4, Pp 235-242 (2021)
Gynecology and Minimally Invasive Therapy, Vol 10, Iss 4, Pp 235-242 (2021)
Objective: To compare the clinical efficacy and urodynamic parameter changes between the MiniArc and the Solyx sling for the treatment of female urodynamic stress incontinence (USI). Materials and Methods: One-hundred and thirty (MiniArc n = 79, BS-S
Publikováno v:
Taiwanese Journal of Obstetrics & Gynecology, Vol 55, Iss 4, Pp 519-524 (2016)
Objective Voiding dysfunction following a midurethral sling procedure is still a relevant consequence that can affect patients' quality of life. Various invasive methods have been described to manage this problem. We hypothesize that we if we could d
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.