Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Mingzhen Ji"'
Publikováno v:
Energy and Built Environment, Vol 2, Iss 2, Pp 127-136 (2021)
A three-dimensional finite element dynamic simulation platform of the ground source heat pump system (GSHPS) is established. According to the outlet temperature of ground heat exchangers (GHEs) required by the code in summer and winter, the calculate
Externí odkaz:
https://doaj.org/article/126f3112e4464591801976e1d90f0b87
Publikováno v:
Energy and Built Environment, Vol 2, Iss 2, Pp 127-136 (2021)
A three-dimensional finite element dynamic simulation platform of the ground source heat pump system (GSHPS) is established. According to the outlet temperature of ground heat exchangers (GHEs) required by the code in summer and winter, the calculate
Publikováno v:
Renewable Energy. 163:262-275
Considering heat and moisture transfer, seepage and freezing simultaneously, a three-dimensional dynamic simulation platform of the ground source heat pump system (GSHPS) is established. Based on this platform, the annual performance of the GSHPS is
Publikováno v:
Leida xuebao, Vol 13, Iss 2, Pp 471-484 (2024)
The global scattering-center model is a high-performance electromagnetic scattering parametric model for complex targets in an optical region. The traditional methods for constructing global scattering models are usually based on candidate-point scre
Externí odkaz:
https://doaj.org/article/a8d3b0244ff5490689b48fedd5c82e91
Autor:
Jingjing Wang, Yueqing Xie, Ting Wu, Yichun Chen, Mingzhen Jiang, Xuhai Li, Yingrong Ye, Ershun Zhou, Zhengtao Yang
Publikováno v:
Poultry Science, Vol 103, Iss 9, Pp 104027- (2024)
ABSTRACT: Phytic acid (PA) is a natural antioxidant with various biological activities, providing protective effects in multiple animals. Ochratoxin A (OTA) is a mold toxin commonly found in feed, which induces multi-organ damage, with kidney being t
Externí odkaz:
https://doaj.org/article/efe6f282081442f7bd9a202f74cd3a1b
Publikováno v:
Geothermics. 97:102237
Arrangement of pipe group and type of ground heat exchangers (GHEs) are crucial engineering design factors affecting the ground source heat pump system (GSHPS) performance. Taking an office building as the object, based on the built three-dimensional
Publikováno v:
Applied Thermal Engineering. 182:116042
Considering freezing and groundwater flow simultaneously, a three-dimensional finite element dynamic simulation platform of the ground source heat pump system (GSHPS) is established, and the GSHPS performance in an office building is analyzed by usin