Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Mercedes Galindo-Canales"'
Autor:
Pilar Martín-Escudero, Ana María Cabanas, María Luisa Dotor-Castilla, Mercedes Galindo-Canales, Francisco Miguel-Tobal, Cristina Fernández-Pérez, Manuel Fuentes-Ferrer, Romano Giannetti
Publikováno v:
Bioengineering, Vol 10, Iss 2, p 254 (2023)
The market for wrist-worn devices is growing at previously unheard-of speeds. A consequence of their fast commercialization is a lack of adequate studies testing their accuracy on varied populations and pursuits. To provide an understanding of wearab
Externí odkaz:
https://doaj.org/article/6c2ca5467e064cf5883bf66503389a76
Publikováno v:
Biosensors, Vol 11, Iss 10, p 391 (2021)
The myths surrounding women’s participation in sport have been reflected in respiratory physiology. This study aims to demonstrate that continuous monitoring of blood oxygen saturation during a maximal exercise test in female athletes is highly cor
Externí odkaz:
https://doaj.org/article/93bada48b78e4d1ca3e06be88695ae8d
Autor:
Pilar Martín-Escudero, Jesus A. Muñoz-Guerra, Soledad Vargas García-Tenorio, Ester Serrano-Garde, Ana Belén Soldevilla-Navarro, Nuria Cortes-Carrillo, Mercedes Galindo-Canales, Nayade del Prado, Manuel Fuentes-Ferrer, Cristina Fernández-Pérez, Peter Alexander Behnisch, Abraham Brouwer
Publikováno v:
Chemosensors, Vol 9, Iss 4, p 62 (2021)
The anabolic androgenic steroids (AAS) are the most frequently consumed performance enhancing drugs (PED) in sports. In the anti-doping field, the detection of AAS is carried out by the analysis of the athlete’s urine using methodologies based on l
Externí odkaz:
https://doaj.org/article/f67137d24671487396bb553bf50d3ed2
Autor:
Manuel Fuentes-Ferrer, Náyade del Prado, Abraham Brouwer, Peter A. Behnisch, Mercedes Galindo-Canales, Cristina Fernández-Pérez, Soledad Vargas García-Tenorio, Ana Belén Soldevilla-Navarro, Ester Serrano-Garde, Nuria Cortes-Carrillo, Jesús Muñoz-Guerra, Pilar Martín-Escudero
Publikováno v:
Chemosensors
Volume 9
Issue 4
Chemosensors, Vol 9, Iss 62, p 62 (2021)
Chemosensors, 9(4):62, 1-12. MDPI Multidisciplinary Digital Publishing Institute
Martín-Escudero, P, Muñoz-Guerra, J A, García-Tenorio, S V, Serrano-Garde, E, Soldevilla-Navarro, A B, Cortes-Carrillo, N, Galindo-Canales, M, Prado, N D, Fuentes-Ferrer, M, Fernández-Pérez, C, Behnisch, P A & Brouwer, A 2021, ' Bioanalytical detection of steroid abuse in sports based on the androgenic activity measurement ', Chemosensors, vol. 9, no. 4, 62, pp. 1-12 . https://doi.org/10.3390/chemosensors9040062
Volume 9
Issue 4
Chemosensors, Vol 9, Iss 62, p 62 (2021)
Chemosensors, 9(4):62, 1-12. MDPI Multidisciplinary Digital Publishing Institute
Martín-Escudero, P, Muñoz-Guerra, J A, García-Tenorio, S V, Serrano-Garde, E, Soldevilla-Navarro, A B, Cortes-Carrillo, N, Galindo-Canales, M, Prado, N D, Fuentes-Ferrer, M, Fernández-Pérez, C, Behnisch, P A & Brouwer, A 2021, ' Bioanalytical detection of steroid abuse in sports based on the androgenic activity measurement ', Chemosensors, vol. 9, no. 4, 62, pp. 1-12 . https://doi.org/10.3390/chemosensors9040062
The anabolic androgenic steroids (AAS) are the most frequently consumed performance enhancing drugs (PED) in sports. In the anti-doping field, the detection of AAS is carried out by the analysis of the athlete’s urine using methodologies based on l
Publikováno v:
Biosensors
Volume 11
Issue 10
E-Prints Complutense. Archivo Institucional de la UCM
instname
Biosensors, Vol 11, Iss 391, p 391 (2021)
Volume 11
Issue 10
E-Prints Complutense. Archivo Institucional de la UCM
instname
Biosensors, Vol 11, Iss 391, p 391 (2021)
The myths surrounding women’s participation in sport have been reflected in respiratory physiology. This study aims to demonstrate that continuous monitoring of blood oxygen saturation during a maximal exercise test in female athletes is highly cor
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::226954553ee39e2a19014c78fced5796
https://eprints.ucm.es/id/eprint/70834/
https://eprints.ucm.es/id/eprint/70834/
Autor:
Náyade del Prado, Jesús Muñoz-Guerra, Pilar Martín-Escudero, Ester Serrano Garde, Manuel Fuentes-Ferrer, Soledad Vargas García-Tenorio, Mercedes Galindo-Canales, Ana Belén Soldevilla-Navarro, Cristina Fernández-Pérez
Publikováno v:
Steroids. 141:104-113
This article studies the genetic influence of polymorphism of the UGT2B17 gen on the urinary steroid profile and its implications for the anti-doping field. The study presents the results of a triple-blind randomized placebo-controlled crossover tria
Autor:
Jesús J Rojo-González, Mercedes Galindo-Canales, Juan José Ramos-Álvarez, Francisco Javier Calderón-Montero, María I Barriopedro
Publikováno v:
Minerva Cardioangiologica, ISSN 0026-4725, 2019-04, Vol. 67, No. 2
Archivo Digital UPM
instname
Archivo Digital UPM
instname
Arterio-venous oxygen difference is very high at rest (70-80%) and is the main determinant to set an increase in coronary blood fiow as the major mechanism to meet myocardial oxygen requirements during exercise. Cor onary blood fiow is not evenly d
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ef48a81b6b1f6b81fd844f15bd9239bf
http://oa.upm.es/64845/
http://oa.upm.es/64845/
Publikováno v:
Apunts: Medicina de l'esport; 2011: Vol.: 46 Núm.: 169; p. 23-27
La pulsioximetría sirve para determinar el porcentaje de saturación de oxígeno que hay en sangre. Su mayor característica es que se trata de un método no invasivo y relativamente económico. Existen pocos estudios que relacionen pulsioximetría
Autor:
Francisco Miguel-Tobal, Náyade del Prado, Ana B. Soldevilla, Manuel Fuentes Ferrer, Cristina Fernández-Pérez, Soledad Vargas, Mercedes Galindo Canales, Marisa Maestro de las Casas, Ester Serrano-Garde, Pilar Martín-Escudero, Jesús Muñoz-Guerra
Publikováno v:
Physiological Reports
The measurement of the testosterone to epitestosterone ratio (T/E ratio) in urine is often used as a marker for testosterone administration in the doping control field. This study examines the frequencies of the different expression forms of the UGT2
Autor:
Romano Giannetti, Dolores Golmayo Fernández, Francisco Miguel-Tobal, Amaya Bilbao Monasterio, Pilar Martín Escudero, Sonnia María López-Silva, María Luisa Dotor Castilla, Mercedes Galindo Canales, J.P. Silveira
Publikováno v:
Journal of Medical and Biological Engineering. 32:181
Photoplethysmography (PPG) is a non-invasive optical technique that can be used to quantify the arterial blood pulse rate. Signal corruption by motion artifacts limits the practical accuracy and applicability of instruments for monitoring pulse rate