Zobrazeno 1 - 10
of 109
pro vyhledávání: '"Melikov Arsen K."'
Autor:
Bivolarova Mariya P., Kierat Wojciech, Hvidkjær Signe, Stengade Kathrine-Amalie, Illum Trine, Boe Gad Stine, Melikov Arsen K.
Publikováno v:
E3S Web of Conferences, Vol 396, p 02032 (2023)
This study aimed to explore an alternative solution for protection against cross-infection. Exposure reduction to exhaled airborne contaminants by wearing an exhaust nozzle was studied. Experiments were performed in a full-scale test room (64.8 m3) e
Externí odkaz:
https://doaj.org/article/357a53dc895943afa9fb268915a2c126
Publikováno v:
E3S Web of Conferences, Vol 356, p 05001 (2022)
The impact of the supplied airflow rate on the distribution and exposure of exhaled airborne pathogens in a room with mixing ventilation was studied. Experiments were conducted in a field laboratory at three supply airflow rates: 20, 40, 60 L/s. Two
Externí odkaz:
https://doaj.org/article/11946f6275e54c7a82432f8485cbba3a
Publikováno v:
E3S Web of Conferences, Vol 356, p 05014 (2022)
The objective of this study was to investigate the importance of room air distribution in airborne cross-infection. Tracer gas measurements were performed in a field lab arranged as an office with two breathing thermal manikins. The room was ventilat
Externí odkaz:
https://doaj.org/article/665991ce2bde4fcca98836fca3b3ae86
Publikováno v:
E3S Web of Conferences, Vol 246, p 02003 (2021)
Three novel air terminal devices (ATDs) for localized ventilation were designed (ATD with perforated inner plate, ATD with honeycomb diffuser, and ATD with lobbed nozzle). The ability of the ATDs to provide clean air to the breathing zone of a person
Externí odkaz:
https://doaj.org/article/07760386531b4147b0225b317c12d41a
Autor:
Melikov Arsen K., Markov Detelin G.
Publikováno v:
E3S Web of Conferences, Vol 111, p 05007 (2019)
The present ventilation design practice as well as the ventilation standards and building regulations are based on the assumption for complete mixing of air in occupied spaces. Required flow rate of outdoor air for dilution of metabolic CO2 generated
Externí odkaz:
https://doaj.org/article/0560ad226e8a4c20b5bef5aca945ad96
Publikováno v:
E3S Web of Conferences, Vol 111, p 02005 (2019)
CFD simulations were performed to investigate occupants’ exposure to metabolic CO2 in a room with mechanical ventilation. A meeting room occupied by six adult people performing sedentary activity was simulated. Five of the six occupants were simula
Externí odkaz:
https://doaj.org/article/dc743a0a4a434289a391e15dd922c7cb
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Thermal comfort affects the sleep quality and well-being of people. The effect of a ventilated mattress (VM with integrated localized heating on providing the necessary thermal conditions for comfort in the bed-microenvironment was studied. The VM ha
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::db94426b2bc44134ef9baa255df6288c