Anna M. Galea, Maysun Hasan, Conor D. Barrett, Wener Lv, Gordon B. Hirschman, Kichang Lee, Antonis A. Armoundas, Richard J. Cohen, Tatsuya J. Arai, Maya E. Barley, Robert P. Marini, Alison Hayward
Publikováno v:
Springer US
We have developed a system that could potentially be used to identify the site of origin of ventricular tachycardia (VT) and to guide a catheter to that site to deliver radio-frequency ablation therapy. This system employs the Inverse Solution Guidan
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f63fb59964193fa861739778ddedd948
https://hdl.handle.net/1721.1/127822
https://hdl.handle.net/1721.1/127822
Autor:
Anna M. Galea, Richard J. Cohen, Conor D. Barrett, Kristen LeRoy, Maya E. Barley, Kichang Lee, Evgeny Ter-Ovanesyan, Robert P. Marini, Gordon B. Hirschman, Antonis A. Armoundas, Wener Lv, Graham E. Voysey
Publikováno v:
Pacing and Clinical Electrophysiology. 36:811-822
Background We developed and evaluated a novel system for guiding radiofrequency catheter ablation therapy of ventricular tachycardia. This guidance system employs an inverse solution guidance algorithm (ISGA) using a single equivalent moving dipole (
Autor:
Kichang, Lee, Wener, Lv, Evgeny, Ter-Ovanesyan, Maya E, Barley, Graham E, Voysey, Anna M, Galea, Gordon B, Hirschman, Kristen, Leroy, Robert P, Marini, Conor, Barrett, Antonis A, Armoundas, Richard J, Cohen
Publikováno v:
Pacing and clinical electrophysiology : PACE. 36(7)
We developed and evaluated a novel system for guiding radiofrequency catheter ablation therapy of ventricular tachycardia. This guidance system employs an inverse solution guidance algorithm (ISGA) using a single equivalent moving dipole (SEMD) local
Publikováno v:
IEEE transactions on bio-medical engineering. 56(3)
Treatment of hemodynamically unstable ventricular arrhythmias requires rapid and accurate localization of the reentrant circuit. We have previously described an algorithm that uses the single-equivalent moving dipole model to rapidly identify both th
Autor:
T.S. Rosbury, Richard J. Cohen, Gordon B. Hirschman, Antonis A. Armoundas, Anna M. Galea, K. J. Choppy, Maya E. Barley
Accurate guidance of an ablation catheter is critical in the radio-frequency ablation of ventricular tachycardia. With current technologies it is challenging to rapidly and accurately localize the site of origin of an arrhythmia, often restricting tr
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5c606870d06d3d63f4b124e9e1ceb669
https://europepmc.org/articles/PMC4528612/
https://europepmc.org/articles/PMC4528612/
High-precision guidance of ablation catheters to arrhythmic sites using electrocardiographic signals
Autor:
Richard J. Cohen, Maya E. Barley
Publikováno v:
EMBC
Hemodynamically unstable ventricular arrhythmias are frequently untreatable with radio-frequency ablation due to the difficulty of rapidly and accurately localizing the site of origin of an arrhythmia with current technologies. We demonstrate a new c