Zobrazeno 1 - 10
of 94
pro vyhledávání: '"Max Anliker"'
Publikováno v:
Review of Scientific Instruments. 69:1512-1518
Modern streak camera based pulse fluorometers readily allow data collection in two-dimensions. We have developed a modular instrument that is easily adapted for recording time-resolved emission spectra, fluorescence depolarization data, and time seri
Publikováno v:
Proteins: Structure, Function, and Genetics. 14:102-109
A new minimization procedure for the global optimization in cartesian coordinate space of the conformational energy of a polypeptide chain is presented. The Metropolis Monte Carlo minimization is thereby supplemented by a thermalization process, whic
Publikováno v:
Proteins: Structure, Function, and Genetics. 13:223-230
A new two-step procedure has been developed for the docking of flexible oligopeptide chains of unkown conformation to static proteins ofknown structure. In the first step positions and conformations are sampled and the association energy, minimized s
Autor:
Thomas Suter, Hans P. Krayenbühl, Hein P. Osenberg, K L Gould, Max Anliker, Richard L. Kirkeeide, Peter Niederer, Otto M. Hess, Martin Büchi, Markus Muser
Publikováno v:
The International Journal of Cardiac Imaging. 5:93-103
In a collaboration between the University of Texas (software) and the University of Zürich (hardware) a compact, automatic system for biplane quantitative coronary arteriography was developed. The system is based on a 35 mm film projector, a slow-sc
Autor:
M.H. Muser, Max Anliker
Publikováno v:
1991., IEEE International Sympoisum on Circuits and Systems.
For a reproducible and accurate computer-aided analysis of coronary arteriograms, image digitizing devices which offer a minimal geometrical resolution of 1024*1024 pixels are required. A newly developed digital CCD (charge coupled device) camera sui
Publikováno v:
1991., IEEE International Sympoisum on Circuits and Systems.
Synthetic aperture techniques have been adopted to improve spatial resolution and provide an extremely fast 3D data acquisition modality for measuring the velocity of relatively fast moving structures such as the heart muscle or blood in arterial ste
Publikováno v:
Acoustical Imaging ISBN: 9781461357971
‘C-Mode Doppler’ is a new real-time technique, that can measure the two dimensional velocity distribution and true volume flow in large blood vessels. An in-vitro study has been carried out for the evaluation of a real time prototype C-Mode Doppl
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c55e9bb1bafbea82476cfc7e8a36102c
https://doi.org/10.1007/978-1-4615-1943-0_55
https://doi.org/10.1007/978-1-4615-1943-0_55
Publikováno v:
Acoustical Imaging ISBN: 9781461357971
A new procedure called ‘C-Mode-Doppler’ has been developed for the quantitative measurement of 2-d velocity fields and the volume flow in large blood vessels. It combines conventional pulse Doppler and holographic techniques and makes use of a 2-
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::44d8075101111940052b088cf67365b4
https://doi.org/10.1007/978-1-4615-1943-0_54
https://doi.org/10.1007/978-1-4615-1943-0_54
Publikováno v:
SPIE Proceedings.
A new versatile system for the measurement of time-resolved fluorescence emission spectra of biomolecules is presented. Frequency doubling and tripling of a Ti:Sapphire laser allows excitation overa wide wavelength range. The influence of increasing
Autor:
Markus H. Muser, Marcel Zimmermann, Reto A. Schwendener, Max Anliker, Urs Graf, Peter F. Niederer, Marc A. Condrau
A time-resolved flow cytometer capable of measuring a luminescence with a decay time in the range of 10 microseconds to 2 ms, typical for some lanthanide chelates, is presented. The instrument permits acquisition of conventional light scatter and pro
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a89efc527670b76ce41d50e783c7103b