Zobrazeno 1 - 10
of 22
pro vyhledávání: '"Mattijs de Groot"'
Publikováno v:
Biophysical Journal. 121:61a
Publikováno v:
Mo, J, de Groot, M & de Boer, J F 2013, ' Focus-extension by depth-encoded synthetic aperture in Optical Coherence Tomography ', Optics Express, vol. 21, no. 8, pp. 10048-10061 . https://doi.org/10.1364/OE.21.010048
Optics Express, 21(8), 10048-10061. The Optical Society
Optics Express, 21(8), 10048-10061. The Optical Society
We present a novel method to extend the depth-of-focus of Optical Coherence Tomography (OCT). OCT is an interferometric imaging technique that provides depth-resolved scattering information. The axial resolution in OCT is provided by the coherence ga
Publikováno v:
The journal of Physical Chemistry. B, 112(14), 4427-4434. American Chemical Society
The electronic structure and spectroscopic properties of the lower excited singlet states of methyl 4-hydroxycinnamate, a model for the chromophore of the photoactive yellow protein in neutral form, have been investigated using various high-resolutio
Publikováno v:
Mo, J, de Groot, M & de Boer, J F 2015, ' Depth-encoded synthetic aperture optical coherence tomography of biological tissues with extended focal depth ', Optics Express, vol. 23, no. 4, pp. 4935-4945 . https://doi.org/10.1364/OE.23.004935
Optics Express, 23(4), 4935-4945. The Optical Society
Optics Express, 23(4), 4935-4945. The Optical Society
Optical coherence tomography (OCT) has proven to be able to provide three-dimensional (3D) volumetric images of scattering biological tissues for in vivo medical diagnostics. Unlike conventional optical microscopy, its depth-resolving ability (axial
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c77145d0f4b196de6c0a21fbac5dfaa9
https://research.vu.nl/en/publications/60826807-cd82-4884-b8a0-c621886847fe
https://research.vu.nl/en/publications/60826807-cd82-4884-b8a0-c621886847fe
Publikováno v:
SPIE Proceedings.
We present a miniature motorized endoscopic probe for Optical Frequency Domain Imaging with an outer diameter of 1.65 mm and a rotation speed of 3,000 ‒ 12,500 rpm. The probe has a motorized distal end which provides a significant advantage over pr
Publikováno v:
Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XVII.
We present a miniature motorized endoscopic probe for Optical Frequency Domain Imaging with an outer diameter of 1.65 mm and a rotation speed of 3,000 – 12,500 rpm. This is the smallest motorized high speed OCT probe to our knowledge. The probe has
Autor:
Johannes F. de Boer, Davide Iannuzzi, Mattijs de Groot, Anna E. C. Meijering, Jianhua Mo, D.C. Chavan
Publikováno v:
Optics Letters
Optics Letters, 38(9), 1476-1478. The Optical Society
Chavan, D C, Mo, J, de Groot, M, Meijering, A E C, de Boer, J F & Iannuzzi, D 2013, ' Collecting optical coherence elastography depth profiles with a micromachined cantilever probe ', Optics Letters, vol. 38, no. 9, pp. 1476-1478 . https://doi.org/10.1364/OL.38.001476
Optics Letters, 38(9), 1476-1478. The Optical Society
Chavan, D C, Mo, J, de Groot, M, Meijering, A E C, de Boer, J F & Iannuzzi, D 2013, ' Collecting optical coherence elastography depth profiles with a micromachined cantilever probe ', Optics Letters, vol. 38, no. 9, pp. 1476-1478 . https://doi.org/10.1364/OL.38.001476
We present an experimental setup that combines optical coherence elastography depth sensing with atomic force microscope indentation. The instrument relies on a miniaturized cantilever probe that compresses a sample with a small footprint force and s
Publikováno v:
ResearcherID
Quantitative phase imaging has many applications for label-free studies of the nanoscale structure and dynamics of cells and tissues. It has been demonstrated that optical coherence phase microscopy (OCPM) can provide quantitative phase information w
Autor:
Mattijs de Groot, Jianan Li, Frank Helderman, Johannes M.A. Daniels, Jianhua Mo, Johannes F. de Boer, Katrien Grünberg, T. G. Sutedja
Publikováno v:
Optics Express, 20(22), 24132-24138. The Optical Society
Li, J A, de Groot, M, Helderman, F, Mo, J, Daniels, J M A, Grünberg, K, Sutedja, G T & de Boer, J F 2012, ' High speed miniature motorized endoscopic probe for optical frequency domain imaging ', Optics Express, vol. 20, no. 22, pp. 24132-24138 . https://doi.org/10.1364/OE.20.024132
ResearcherID
Li, J A, de Groot, M, Helderman, F, Mo, J, Daniels, J M A, Grünberg, K, Sutedja, G T & de Boer, J F 2012, ' High speed miniature motorized endoscopic probe for optical frequency domain imaging ', Optics Express, vol. 20, no. 22, pp. 24132-24138 . https://doi.org/10.1364/OE.20.024132
ResearcherID
We present a miniature motorized endoscopic probe for Optical Coherence Tomography with an outer diameter of 1.65 mm and a rotation speed of 3,000-12,500 rpm. This is the smallest motorized high speed OCT probe to our knowledge. The probe has a motor
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::738f90695e89e515e255fd8857eebda7
https://research.vu.nl/en/publications/24aeabfb-9e78-4bf7-89a2-e3c261ea4921
https://research.vu.nl/en/publications/24aeabfb-9e78-4bf7-89a2-e3c261ea4921
Publikováno v:
Journal of Chemical Physics, 126(20):204312, 204312-204312. AMER INST PHYSICS
Journal of Chemical Physics, 126(20), 204312/1-204312/4. American Institute of Physics
Journal of Chemical Physics, 126(20), 204312/1-204312/4. American Institute of Physics
Two-dimensional photoelectron spectroscopy has been used to supply process-specific labels to multiphoton ionization events. Employing these tags, the authors can construct excitation and photoelectron spectra along predefined excitation routes in th