Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Matthijs F Kruis"'
Publikováno v:
Physics in medicine and biology. 62(6)
The image quality of respiratory sorted four-dimensional (4D) cone-beam (CB) computed tomography (CT) is often limited by streak artifacts due to insufficient projections. A motion weighted reconstruction (MWR) method is proposed to decrease streak a
Autor:
Jeroen B. van de Kamer, Antonetta C. Houweling, Jan-Jakob Sonke, Matthijs F. Kruis, Marcel van Herk, José Belderbos
Publikováno v:
International journal of radiation oncology, biology, physics, 87(2), 394-400. Elsevier Inc.
Purpose Four-dimensional positron emission tomography (4D PET) imaging of the thorax produces sharper images with reduced motion artifacts. Current radiation therapy planning systems, however, do not facilitate 4D plan optimization. When images are a
Autor:
Marcel van Herk, José Belderbos, Jeroen B. van de Kamer, Matthijs F. Kruis, Jan-Jakob Sonke, Wouter V. Vogel
Publikováno v:
EJNMMI physics, 2(1). Springer International Publishing AG
EJNMMI Physics
EJNMMI Physics
Background In contemporary positron emission tomography (PET)/computed tomography (CT) scanners, PET attenuation correction is performed by means of a CT-based attenuation map. Respiratory motion can however induce offsets between the PET and CT data
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b36b8a206bc0fb48417556bf2b43b0a7
https://pure.amc.nl/en/publications/clinical-evaluation-of-respirationinduced-attenuation-uncertainties-in-pulmonary-3d-petct(e85c6453-1a92-4831-b0aa-a90025253817).html
https://pure.amc.nl/en/publications/clinical-evaluation-of-respirationinduced-attenuation-uncertainties-in-pulmonary-3d-petct(e85c6453-1a92-4831-b0aa-a90025253817).html
Publikováno v:
Physics in medicine and biology, 59(18), 5517-5529. IOP Publishing Ltd.
The purpose of this study was to develop a method to use amplitude binned 4D-CT (A-4D-CT) data for the construction of mid-position CT data and to compare the results with data created from phase-binned 4D-CT (P-4D-CT) data. For the latter purpose we
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::dfc2e4d097433847146f460cbd1378f6
https://pure.amc.nl/en/publications/4d-ct-amplitude-binning-for-the-generation-of-a-timeaveraged-3d-midposition-ct-scan(80e23790-0824-4247-8818-48dd8b1c0241).html
https://pure.amc.nl/en/publications/4d-ct-amplitude-binning-for-the-generation-of-a-timeaveraged-3d-midposition-ct-scan(80e23790-0824-4247-8818-48dd8b1c0241).html
Autor:
Matthijs F. Kruis, Marcel van Herk, Jan-Jakob Sonke, Jeroen B. van de Kamer, Edwin P.M. Jansen
Publikováno v:
Radiotherapy and oncology, 109(3), 404-408. Elsevier Ireland Ltd
Purpose and background The purpose was to validate the accuracy of motion models derived from deformable registration from four-dimensional computed tomography (4DCT) and breath-hold contrast enhanced computed tomography (BHCCT) scans for liver SBRT.
Publikováno v:
Radiotherapy and Oncology. 106:S212-S213
Autor:
J.J. Sonke, Matthijs F. Kruis, Antonetta C. Houweling, N.M. Bruin, S.L. Takken, M. van Herk, Maddalena Rossi, Wouter V. Vogel, M. Vijlbrief-Bosman
Publikováno v:
Radiotherapy and Oncology. 106:S170-S171
Autor:
M. van Herk, J. Van de Kamer, Matthijs F. Kruis, M. Frantzen-Steneker, J.J. Sonke, Mario Maas
Publikováno v:
Radiotherapy and Oncology. 99:S431
Publikováno v:
Radiotherapy and Oncology. :S57
Autor:
Matthijs F Kruis, Jeroen B van de Kamer, José S A Belderbos, Jan-Jakob Sonke, Marcel van Herk
Publikováno v:
Physics in Medicine & Biology; 9/21/2014, Vol. 59 Issue 18, p1-1, 1p