Zobrazeno 1 - 10
of 37
pro vyhledávání: '"Matthijs C. M. Grimbergen"'
Autor:
Andru Putra Twinanda, Quirijn A J Eijsbouts, Helena A Kloosterman, Annetje C. P. Guédon, Matthijs C M Grimbergen, Karlijn J van Stralen, John J. van den Dobbelsteen, Senna E P Meij, Karim N M M H Osman
Publikováno v:
Surgical Endoscopy, 35(11), 6150-6157. Springer New York
Surgical Endoscopy: surgical and interventional techniques (online), 35 (2021)(11)
Guédon, A C P, Meij, S E P, Osman, K N M M H, Kloosterman, H A, van Stralen, K J, Grimbergen, M C M, Eijsbouts, Q A J, van den Dobbelsteen, J J & Twinanda, A P 2021, ' Deep learning for surgical phase recognition using endoscopic videos ', Surgical Endoscopy, vol. 35, no. 11, pp. 6150-6157 . https://doi.org/10.1007/s00464-020-08110-5
Surgical Endoscopy: surgical and interventional techniques (online), 35 (2021)(11)
Guédon, A C P, Meij, S E P, Osman, K N M M H, Kloosterman, H A, van Stralen, K J, Grimbergen, M C M, Eijsbouts, Q A J, van den Dobbelsteen, J J & Twinanda, A P 2021, ' Deep learning for surgical phase recognition using endoscopic videos ', Surgical Endoscopy, vol. 35, no. 11, pp. 6150-6157 . https://doi.org/10.1007/s00464-020-08110-5
Background: Operating room planning is a complex task as pre-operative estimations of procedure duration have a limited accuracy. This is due to large variations in the course of procedures. Therefore, information about the progress of procedures is
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7b1daa785dd92c75b482d6bd79e14ad2
https://research.vumc.nl/en/publications/c9d1b380-9aef-442b-ba49-905430ada2c9
https://research.vumc.nl/en/publications/c9d1b380-9aef-442b-ba49-905430ada2c9
Autor:
Annetje C P, Guédon, Senna E P, Meij, Karim N M M H, Osman, Helena A, Kloosterman, Karlijn J, van Stralen, Matthijs C M, Grimbergen, Quirijn A J, Eijsbouts, John J, van den Dobbelsteen, Andru P, Twinanda
Publikováno v:
Surgical endoscopy. 35(11)
Operating room planning is a complex task as pre-operative estimations of procedure duration have a limited accuracy. This is due to large variations in the course of procedures. Therefore, information about the progress of procedures is essential to
Autor:
Matthijs C. M. Grimbergen, Mark D. den Blanken, Thomas Rustemeyer, Niels Liberton, Mark B.M. Hofman, Ruud Verdaasdonk, Sebastiaan A. S. van der Bent
Publikováno v:
den Blanken, M D, van der Bent, S, Liberton, N, Grimbergen, M, Hofman, M B M, Verdaasdonk, R & Rustemeyer, T 2020, ' Quantification of cutaneous allergic reactions using 3D optical imaging: A feasibility study ', Skin Research and Technology, vol. 26, no. 1, pp. 67-75 . https://doi.org/10.1111/srt.12765
Skin research and technology, 26(1), 67-75. Wiley-Blackwell
Skin Research and Technology, 26(1), 67-75. Wiley-Blackwell
Skin Research and Technology
Skin research and technology, 26(1), 67-75. Wiley-Blackwell
Skin Research and Technology, 26(1), 67-75. Wiley-Blackwell
Skin Research and Technology
Background User‐independent quantitative measures of cutaneous allergic reactions can help the physicians manage and evaluate the treatment of cutaneous allergic reactions. In this paper, we present and validate a method to quantify the elevation,
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ffa7c412be0d7a43fd6d8470e04a5034
https://research.vumc.nl/en/publications/e165dfc3-3e71-4892-bd71-f3178bca1c24
https://research.vumc.nl/en/publications/e165dfc3-3e71-4892-bd71-f3178bca1c24
Publikováno v:
Optical Interactions with Tissue and Cells XXVII.
During laparoscopic surgery, devices are require to either cut, ablate or coagulate tissue and veins with high precision and controlled lateral damage preferably in an one-for-all modality. The tissue interactions of 3 new treatment modalities were s
Autor:
Trudy N. Jonges, Matthijs C. M. Grimbergen, Ronald O.P. Draga, Ruud Bosch, Christiaan F. P. van Swol, Esther T. Kok
Publikováno v:
Draga, R O P, Grimbergen, M C M, Kok, E T, Jonges, T N, Van Swol, C F P & Bosch, R J L H 2012, ' The quality of 5-aminolevulinic acid-induced photodynamic diagnosis and transurethral resection of bladder tumors : Does the urologist play a role? ', Urologia Internationalis, vol. 89, no. 3, pp. 326-331 . https://doi.org/10.1159/000341897
Urologia Internationalis, 89(3), 326-331. S. Karger AG
Urologia Internationalis, 89(3), 326-331. S. Karger AG
Introduction: The aim of this study is to evaluate the quality of photodynamic diagnosis (PDD) and transurethral resection of bladder tumors (TURBT) among different urologists. Patients and Methods: The selected data consists of 194 patients, 268 5-a
Autor:
Ronald O.P. Draga, Trudy N. Jonges, Matthijs C. M. Grimbergen, Esther T. Kok, J.L.H. Ruud Bosch
Publikováno v:
Urology, 74(4), 851-856. Elsevier Inc.
Draga, R O P, Grimbergen, M C M, Kok, E T, Jonges, T N & Bosch, J L H R 2009, ' Predictors of False Positives in 5-Aminolevulinic Acid-induced Photodynamic Diagnosis of Bladder Carcinoma : Identification of Patient Groups That May Benefit Most From Highly Specific Optical Diagnostics ', Urology, vol. 74, no. 4, pp. 851-856 . https://doi.org/10.1016/j.urology.2009.04.095
Draga, R O P, Grimbergen, M C M, Kok, E T, Jonges, T N & Bosch, J L H R 2009, ' Predictors of False Positives in 5-Aminolevulinic Acid-induced Photodynamic Diagnosis of Bladder Carcinoma : Identification of Patient Groups That May Benefit Most From Highly Specific Optical Diagnostics ', Urology, vol. 74, no. 4, pp. 851-856 . https://doi.org/10.1016/j.urology.2009.04.095
Objectives To identify patient groups associated with a high probability of false positives in photodynamic diagnosis (PDD) of bladder cancer for which the use of highly specific optical instruments could be beneficial. Methods This study includes th
Autor:
Michelle Agenant, Ronald O.P. Draga, Matthijs C. M. Grimbergen, Eric Marple, Ruud Bosch, Christiaan F. P. van Swol
Publikováno v:
Agenant, M, Grimbergen, M, Draga, R, Marple, E, Bosch, R & van Swol, C 2014, ' Clinical superficial Raman probe aimed for epithelial tumor detection : Phantom model results ', Biomedical Optics Express, vol. 5, no. 4, pp. 1203-1216 . https://doi.org/10.1364/BOE.5.001203
Biomedical Optics Express, 5(4), 1203-1216. The Optical Society
Biomedical Optics Express, 5(4), 1203-1216. The Optical Society
A novel clinical Raman probe for sampling superficial tissue to improve in vivo detection of epithelial malignancies is compared to a non-superficial probe regarding depth response function and signal-to-noise ratio. Depth response measurements were
Autor:
Peter L. M. Vijverberg, J.L.H. Ruud Bosch, Trudy N. Jonges, Christiaan F. P. van Swol, Ronald O.P. Draga, J. Alain Kummer, Matthijs C. M. Grimbergen
Publikováno v:
Analytical Chemistry, 82(14), 5993-5999. American Chemical Society
Draga, R O P, Grimbergen, M C M, Vijverberg, P L M, Swol, C F P V, Jonges, T G N, Kummer, J A & Ruud Bosch, J L H 2010, ' In vivo bladder cancer diagnosis by high-volume Raman spectroscopy ', Analytical Chemistry, vol. 82, no. 14, pp. 5993-5999 . https://doi.org/10.1021/ac100448p
Draga, R O P, Grimbergen, M C M, Vijverberg, P L M, Swol, C F P V, Jonges, T G N, Kummer, J A & Ruud Bosch, J L H 2010, ' In vivo bladder cancer diagnosis by high-volume Raman spectroscopy ', Analytical Chemistry, vol. 82, no. 14, pp. 5993-5999 . https://doi.org/10.1021/ac100448p
We studied the feasibility of Raman spectroscopy for the diagnosis of bladder cancer in vivo. Since the invasion stage is crucial for the treatment choice, a high-volume based Raman probe was used to investigate the potential of determining the invas
Autor:
Ronald O.P. Draga, M. T. W. Tycho Lock, Herke Jan Noordmans, Matthijs C. M. Grimbergen, J.L.H. Ruud Bosch
Publikováno v:
Draga, R O P, Noordmans, H J, Lock, M T W T, Grimbergen, M C M & Bosch, J L H R 2010, The feasibility of real-time bladder mapping using a stereotactic navigational system . in Photonic Therapeutics and Diagnostics VI ., 75481M, Progress in Biomedical Optics and Imaging-Proceedings of SPIE, vol. 7548, Photonic Therapeutics and Diagnostics VI, San Francisco, CA, United States, 23/01/2010 . https://doi.org/10.1117/12.841335
Photonic Therapeutics and Diagnostics VI
Photonic Therapeutics and Diagnostics VI
Stereotactic navigational devices have been implemented in neurosurgery, orthopedics and ear-nose-throat to improve surgical accuracy. However, the feasibility of navigating inside the bladder has not yet been investigated. Occasionally, transurethra
Autor:
Matthijs C. M. Grimbergen, Rudolf M. Verdaasdonk, Stefan Been, Tjeerd de Boorder, Herke Jan Noordmans
Publikováno v:
De Boorder, T, Noordmans, H J, Grimbergen, M, Been, S & Verdaasdonk, R 2010, Quantitative comparison of three electrosurgical smoke evacuation systems . in Design and Quality for Biomedical Technologies III ., 75560V, Progress in Biomedical Optics and Imaging-Proceedings of SPIE, vol. 7556, Design and Quality for Biomedical Technologies III, San Francisco, CA, United States, 25/01/2010 . https://doi.org/10.1117/12.842574
Design and Quality for Biomedical Technologies III
Design and Quality for Biomedical Technologies III
Electrosurgical equipment used during surgery generate smoke consisting of particles, vapor, aerosols and potentially harmful biological agents. Smoke evacuation systems are used more commonly and various types are available. A special image enhancem